SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML1106-2BB20-0B SIEMENS EchoMax XRS-5 Ultrasonic level transducer: continuous, non-contact, 8 m (26 ft) ran..

SIEMENS

Manufacturer Code: 7ML1106-2BB20-0B
Reference: 7ML1106-2BB20-0B
Catalog Number: -
EchoMax XRS-5 Ultrasonic level transducer: continuous, non-contact, 8 m (26 ft) range, for liquids and slurries. Mounting thread: R 1" ((BSPT), EN 10226) Cable length: 10 m (32.81 ft) Facing: PTFE (flange versions) Approvals: CSA Class I, Div. 2, Groups A, B, C, D; CSA Class II, Div. 1, Groups E, F, G; FM Class I, Zone 1, AEx m IIC, T6; FM Class II, III, Div. 1, Groups E, F, G T6; ATEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; ATEX II 2GD Ex tb IIIC T85°C Db; UKEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; UKEX II 2GD Ex tb IIIC T85°C Db; IECEx Ex mb IIC T6 Gb, Ta = -20°C to +65°C; IECEx Ex tb IIIC T85°C Db; INMETRO Ex mb IIC T6 Gb, IP66/IP68, -20°C ≤ Ta ≤ +65°C; INMETRO Ex tb IIIC T85°C Db, IP66/IP68; CE, UKCA, RCM, KC, EAC Ex . .
EchoMax XRS-5 Ultrasonic Level Sensor: Continuous, non-contact measurement, range 8 m (26 ft) for liquids and slurries. "Process connection thread: 1"" BSP." Connection cable length: 10 m. Coating: Teflon (only in the EN type mount flange execution). Approval: CSA Class I, Div. 2, Groups A, B, C, D; CSA Class II, Div. 1, Groups E, F, G; FM Class I, Zone 1, AEx m IIC, T6; FM Class II, III, Div. 1, Groups E, F, G T6; ATEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; ATEX II 2GD Ex tb IIIC T85°C Db; UKEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; UKEX II 2GD Ex tb IIIC T85°C Db; IECEx Ex mb IIC T6 Gb, Ta = -20°C to +65°C; IECEx Ex tb IIIC T85°C Db; INMETRO Ex mb IIC T6 Gb, IP66/IP68, -20°C ≤ Ta ≤ +65°C; INMETRO Ex tb IIIC T85°C Db, IP66/IP68; CE, UKCA, RCM, KC, EAC Ex Instructions manual: Multi-Language Quick Start. "Mounting flange: 3"" ANSI, 150 lb."
Delivery: See availability
7ND4461-2AD16-1CE2 SIEMENS SIREC D400 Displayrecorder Front dimensions 300 x 300 mm, for all applications sc..

SIEMENS

Manufacturer Code: 7ND4461-2AD16-1CE2
Reference: 7ND4461-2AD16-1CE2
Catalog Number: -
SIREC D400 - Displayrecorder Front dimensions 300 x 300 mm, for all applications scanning rate: 200 ms of mA, V,mV; Rearsite: Ethernet; RS485; USB interfaces Front side: Slot for CF-Card; USB interface; AC 50 or 60 Hz, 90 to 240 V, Power supply: 24V DC max. 200 mA Allocation plug-in position 1 till 4: 16 analog inputs, none pulse inputs . Allocation plug-in position 5 and 6: 8 Analog Inputs Analog Outputs: none Switching Outputs and Switching Inputs (devided into 3 plug-in positions): 4 Relays (240 V) 1 GByte Internal memory expansion Extended System Security (ESS): Without 20 Credits IP66 (NEMA 4X), with Seismic capability Manual in English
SIREC D400 Display Recorder Front dimensions 300 X 300 mm, for all applications, cycle time: 200 ms for mA, V, mV; 500 ms for TC/RTD/R, Rear side: Ethernet interface; RS485; USB interface; front side: CF card slot; USB AC interface 50 or 60 HZ, 90 to 240 V, transmitter power: 24 V DC max. 200 mA Allocation plug-in position 1 till 4: 16 analog inputs, none pulse inputs . Slot Assignment 5 & 6: Analog Inputs/Pulse Inputs: 8 Analog Inputs, No Analog Outputs Binary Outputs and Binary Inputs (Spread Over Three Slots): 4 Relays (240 V) 1 GByte Extended System Security (ESS) Internal Data Memory: Without 20 IP66 (NEMA 4X) credits, with Earthquake Resistant version English Language Manual.
Delivery: See availability
7ND4461-2AC16-1CE2 SIEMENS SIREC D400 Displayrecorder Front dimensions 300 x 300 mm, for all applications sc..

SIEMENS

Manufacturer Code: 7ND4461-2AC16-1CE2
Reference: 7ND4461-2AC16-1CE2
Catalog Number: -
SIREC D400 - Displayrecorder Front dimensions 300 x 300 mm, for all applications scanning rate: 200 ms of mA, V,mV; Rearsite: Ethernet; RS485; USB interfaces Front side: Slot for CF-Card; USB interface; AC 50 or 60 Hz, 90 to 240 V, Power supply: 24V DC max. 200 mA Allocation plug-in position 1 till 4: 16 analog inputs, none pulse inputs . Allocation plug-in position 5 and 6: 0 Analog Inputs Analog Outputs: 4AA Switching Outputs and Switching Inputs (devided into 3 plug-in positions): 4 Relays (240 V) 1 GByte Internal memory expansion Extended System Security (ESS): Without 20 Credits IP66 (NEMA 4X), with Seismic capability Manual in English
SIREC D400 Display Recorder Front dimensions 300 X 300 mm, for all applications, cycle time: 200 ms for mA, V, mV; 500 ms for TC/RTD/R, Rear side: Ethernet interface; RS485; USB interface; front side: CF card slot; USB AC interface 50 or 60 HZ, 90 to 240 V, transmitter power: 24 V DC max. 200 mA Allocation plug-in position 1 till 4: 16 analog inputs, none pulse inputs . Slot Assignment 5 & 6: Analog Inputs/Pulse Inputs: 0 Analog Inputs, Analog Outputs: 4 AO Binary Outputs and Binary Inputs (spread over three slots): 4 relays (240 V) 1 GByte Extended System Security (ESS) internal data memory: Without 20 IP66 credits (NEMA 4X), with seismic resistant version English language manual.
Delivery: See availability

products sitemap