SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7MH7112-2AD10 SIEMENS SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for u..

SIEMENS

Manufacturer Code: 7MH7112-2AD10
Reference: 7MH7112-2AD10
Catalog Number: -
SITRANS WFS320 solids flowmeter sensing head, Out-of-the-process sensing element for use with WF330, WF340 and WF350 flowmeters. A flowguide, sensing plate and integrator are required to complete the system. Classification: hazardous CSA, FM Class I Div. 1 Groups C & D;Class II, Gr. E, F & G, Ex nA IIC T6 Gc, ATEX II 2D - Ex tb IIIC T70 C Db IP64,IECEx FMG 13.0016X,Ex nA IIC T6 Gc, Ex TB IIIC T70 C Db IP64,EAC Ex Range (Range spring size/viscosity of damping fluid): D1/1000 Position 1 Gaskets: PTFE Coating, process side only: Epoxy - white/aluminum, external castings only Sensing Head Mounted LVDT Conditioner: not required
SITRANS WFS320 Sensing Head: Bulk Solids Flowmeter suitable for low to medium capacity applications. Min. accuracy ± 1%, capacity up to 300 t/h (330 STPH). Classification: CSA/FM Class I, Div. 1, Groups C, D, Class II, Div. 1, Groups E, F, G; ATEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; UKEX II 2D Ex tb IIIC T70°C Db, -40°C = Ta = +60°C, IP64; ATEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; UKEX II 3G Ex ec IIC T6 Gc, -40°C = Ta = +60°C, IP64; IECEx Ex tb IIIC T70°C Db, Ta = -40°C to +60°C, IP64; IECEx Ex ec IIC T6 Gc, Ta = -40°C to +60°C; EAC Ex Ex tb IIIC T70°C Db X; EAC Ex Ex nA IIC T6 Gc X Range: (spring size/ buffer liquid viscosity) D1/1,000, position 1. Sealing Gaskets: PTFE Coating: (Single Process Contact Side) Epoxy - white/aluminum, external castings only LVDT card in sensor head: None
Delivery: See availability
7ND4461-2AA16-1EE2 SIEMENS SIREC D400 Displayrecorder Front dimensions 300 x 300 mm, for all applications sc..

SIEMENS

Manufacturer Code: 7ND4461-2AA16-1EE2
Reference: 7ND4461-2AA16-1EE2
Catalog Number: -
SIREC D400 - Displayrecorder Front dimensions 300 x 300 mm, for all applications scanning rate: 200 ms of mA, V,mV; Rearsite: Ethernet; RS485; USB interfaces Front side: Slot for CF-Card; USB interface; AC 50 or 60 Hz, 90 to 240 V, Power supply: 24V DC max. 200 mA Allocation plug-in position 1 till 4: 16 analog inputs, none pulse inputs . Allocation plug-in position 5 and 6: 0 Analog Inputs Analog Outputs: none Switching Outputs and Switching Inputs (devided into 3 plug-in positions): 4 Relays (240 V) 1 GByte Internal memory expansion Extended System Security (ESS): Without 40 Credits IP66 (NEMA 4X), with Seismic capability Manual in English
SIREC D400 Display Recorder Front dimensions 300 X 300 mm, for all applications, cycle time: 200 ms for mA, V, mV; 500 ms for TC/RTD/R, Rear side: Ethernet interface; RS485; USB interface; front side: CF card slot; USB AC interface 50 or 60 HZ, 90 to 240 V, transmitter power: 24 V DC max. 200 mA Allocation plug-in position 1 till 4: 16 analog inputs, none pulse inputs . Slot Assignment 5 & 6: Analog Inputs/Pulse Inputs: 0 Analog Inputs, No Analog Outputs Binary Outputs and Binary Inputs (spread over three slots): 4 relays (240 V) 1 GByte Extended System Security (ESS) internal data memory: Without 40 IP66 credits (NEMA 4X), with Earthquake Resistant version English Language Manual.
Delivery: See availability
7ND4461-2AF18-2HE2 SIEMENS SIREC D400 Displayrecorder Front dimensions 300 x 300 mm, for all applications sc..

SIEMENS

Manufacturer Code: 7ND4461-2AF18-2HE2
Reference: 7ND4461-2AF18-2HE2
Catalog Number: -
SIREC D400 - Displayrecorder Front dimensions 300 x 300 mm, for all applications scanning rate: 200 ms of mA, V,mV; Rearsite: Ethernet; RS485; USB interfaces Front side: Slot for CF-Card; USB interface; AC 50 or 60 Hz, 90 to 240 V, Power supply: 24V DC max. 200 mA Allocation plug-in position 1 till 4: 16 analog inputs, none pulse inputs . Allocation plug-in position 5 and 6: 8 Analog Inputs Analog Outputs: 2AA Switching Outputs and Switching Inputs (devided into 3 plug-in positions): 4 Relays (240 V) 4 GByte Internal memory expansion Extended System Security (ESS): With 70 Credits IP66 (NEMA 4X), with Seismic capability Manual in English
SIREC D400 Display Recorder Front dimensions 300 X 300 mm, for all applications, cycle time: 200 ms for mA, V, mV; 500 ms for TC/RTD/R, Rear side: Ethernet interface; RS485; USB interface; front side: CF card slot; USB AC interface 50 or 60 HZ, 90 to 240 V, transmitter power: 24 V DC max. 200 mA Allocation plug-in position 1 till 4: 16 analog inputs, none pulse inputs . Slot Assignment 5 & 6: Analog Inputs/Pulse Inputs: 8 Analog Inputs, Analog Outputs: 2 AO Binary Outputs and Binary Inputs (spread over three slots): 4 relays (240 V) 4 GBytes internal data memory Extended System Security (ESS): With 70 IP66 credits (NEMA 4X), with seismic resistant version English Language Manual.
Delivery: See availability
7ML1106-2AB20-0R SIEMENS EchoMax XRS-5 Ultrasonic level transducer: continuous, non-contact, 8 m (26 ft) ran..

SIEMENS

Manufacturer Code: 7ML1106-2AB20-0R
Reference: 7ML1106-2AB20-0R
Catalog Number: -
EchoMax XRS-5 Ultrasonic level transducer: continuous, non-contact, 8 m (26 ft) range, for liquids and slurries. Mounting thread: R 1" ((BSPT), EN 10226) Cable length: 5 m (16.40 ft) Facing: PTFE (flange versions) Approvals: CSA Class I, Div. 2, Groups A, B, C, D; CSA Class II, Div. 1, Groups E, F, G; FM Class I, Zone 1, AEx m IIC, T6; FM Class II, III, Div. 1, Groups E, F, G T6; ATEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; ATEX II 2GD Ex tb IIIC T85°C Db; UKEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; UKEX II 2GD Ex tb IIIC T85°C Db; IECEx Ex mb IIC T6 Gb, Ta = -20°C to +65°C; IECEx Ex tb IIIC T85°C Db; INMETRO Ex mb IIC T6 Gb, IP66/IP68, -20°C ≤ Ta ≤ +65°C; INMETRO Ex tb IIIC T85°C Db, IP66/IP68; CE, UKCA, RCM, KC, EAC Ex . .
EchoMax XRS-5 Ultrasonic Level Sensor: Continuous, non-contact measurement, range 8 m (26 ft) for liquids and slurries. "Process connection thread: 1"" BSP." Connection cable length: 5 m. Coating: Teflon (only in the EN type mount flange execution). Approval: CSA Class I, Div. 2, Groups A, B, C, D; CSA Class II, Div. 1, Groups E, F, G; FM Class I, Zone 1, AEx m IIC, T6; FM Class II, III, Div. 1, Groups E, F, G T6; ATEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; ATEX II 2GD Ex tb IIIC T85°C Db; UKEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; UKEX II 2GD Ex tb IIIC T85°C Db; IECEx Ex mb IIC T6 Gb, Ta = -20°C to +65°C; IECEx Ex tb IIIC T85°C Db; INMETRO Ex mb IIC T6 Gb, IP66/IP68, -20°C ≤ Ta ≤ +65°C; INMETRO Ex tb IIIC T85°C Db, IP66/IP68; CE, UKCA, RCM, KC, EAC Ex Instructions manual: Multi-Language Quick Start. Mounting flange: JIS10K 4B.
Delivery: See availability

products sitemap