SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ME6820-2YC48-2LA0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-2LA0
Reference: 7ME6820-2YC48-2LA0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors No additional communication module installed Internal batter
Delivery: See availability
7ME6820-2YC48-2MT4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-2MT4
Reference: 7ME6820-2YC48-2MT4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) and a
Delivery: See availability
7ME6820-2YJ00-1KD2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ00-1KD2
Reference: 7ME6820-2YJ00-1KD2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor Encoder Interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: ANSI B16.5: Class 150 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 No verification according to OIML R 49 Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Advanced version integrated in the sensor Transmitter interface module for ITRON 200WP Radio with Sensus Protocol External battery with 1.5 m connection cable (4.9 ft) with IP68/NEMA 6P c
Delivery: See availability
7ME6820-2YJ00-2BA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ00-2BA3
Reference: 7ME6820-2YJ00-2BA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24 Power V AC/DC with battery backup and 3m (9.8 ft) power
Delivery: See availability
7ME6820-2YJ00-2LT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange,..

SIEMENS

Manufacturer Code: 7ME6820-2YJ00-2LT0
Reference: 7ME6820-2YJ00-2LT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Standard Calibration (No Initial Verification) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, 5m (16.5m) Fixed Cable Internal Battery (Battery Not Included).
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) Internal battery (battery not
Delivery: See availability
7ME6820-2YJ02-1CC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ02-1CC0
Reference: 7ME6820-2YJ02-1CC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery (Battery not included)
Delivery: See availability
7ME6820-2YJ02-1LB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ02-1LB1
Reference: 7ME6820-2YJ02-1LB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type & Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Sensor Termination) Built-in internal battery
Delivery: See availability
7ME6820-2YJ02-2BS4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ02-2BS4
Reference: 7ME6820-2YJ02-2BS4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) 115/230V AC power with battery backup and 3m (9.8 ft)
Delivery: See availability
7MF8010-2DM31-5HC1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2DM31-5HC1
Reference: 7MF8010-2DM31-5HC1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according ISO 2852 /DIN 32676: 1 Inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...2,5 bar abs. overload pressure: 10 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Clamp connection according to ISO 2852/ DIN 32676: 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...2.5 bar abs. Overload pressure: 16 bar No explosion protection
Delivery: See availability
7MF8010-2DN31-2FC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2DN31-2FC2
Reference: 7MF8010-2DN31-2FC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according ISO 2852 /DIN 32676: 1 1/2 Inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: -1...1,5 bar overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Clamp connection according to ISO 2852/ DIN 32676: 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Case version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut Measuring range: -1...1.5 bar Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YJ03-2CT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ03-2CT2
Reference: 7ME6820-2YJ03-2CT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and analog cable(2.5m) External battery with 1.5
Delivery: See availability
7ME6820-2YJ03-2LD3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YJ03-2LD3
Reference: 7ME6820-2YJ03-2LD3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Encoder Interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol 12/24 V AC/DC power supply wi
Delivery: See availability
7ME6820-2YJ05-1CC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-1CC1
Reference: 7ME6820-2YJ05-1CC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ05-1NA2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-1NA2
Reference: 7ME6820-2YJ05-1NA2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1=200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Wired External Battery 1.5 m (4.9 ft) connec
Delivery: See availability
7ME6820-2YJ02-2MD4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ02-2MD4
Reference: 7ME6820-2YJ02-2MD4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus 115/230 V AC Power Protocol with B
Delivery: See availability
7ME6820-2YJ03-1PA0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ03-1PA0
Reference: 7ME6820-2YJ03-1PA0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Separated, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Internal Battery (Battery No included)
Delivery: See availability
7MF8010-1BD31-4HB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1BD31-4HB2
Reference: 7MF8010-1BD31-4HB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with screw necks: DN 25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...1,6 bar abs. overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 25 Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable protector, IP65 (small measuring range: 0...1.6 bar abs. Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1BH31-4HA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1BH31-4HA2
Reference: 7MF8010-1BH31-4HA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with screw necks: DN 65 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...1 bar abs. overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 65 Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable protector, IP65 (small measuring range: 0...1 bar abs. Overload pressure: 3 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1BH31-5HA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1BH31-5HA2
Reference: 7MF8010-1BH31-5HA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with screw necks: DN 65 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...1 bar abs. overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 65 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measuring ranges less than 10 bar measuring range: 0...1 bar abs. Overload pressure: 3 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2DQ31-4HB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2DQ31-4HB2
Reference: 7MF8010-2DQ31-4HB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according ISO 2852 /DIN 32676: 2 1/2 Inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...1,6 bar abs. overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded joint on both sides)/ quick releases: Clamp connection according to ISO 2852/ DIN 32676: 2 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measurement range: 0...1.6 bar abs. Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2DQ31-5HA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2DQ31-5HA2
Reference: 7MF8010-2DQ31-5HA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according ISO 2852 /DIN 32676: 2 1/2 Inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...1 bar abs. overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded joint on both sides)/ quick releases: Clamp connection according to ISO 2852/ DIN 32676: 2 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...1 bar abs. Overload pressure: 3 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2QM31-2GB1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2QM31-2GB1
Reference: 7MF8010-2QM31-2GB1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: -1...15 bar overload pressure: 60 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. PNEUMO): 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut Measurement range: –1...15 bar Overload pressure: 50 bar No explosion protection
Delivery: See availability
7ME6820-2YJ05-2BS1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange,..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2BS1
Reference: 7ME6820-2YJ05-2BS1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, 5m Fixed Cable (16.
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) Built-in internal battery
Delivery: See availability
7ME6820-2YJ05-2PB4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2PB4
Reference: 7ME6820-2YJ05-2PB4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of 115/230 V AC power with battery backup
Delivery: See availability
7ME6820-2YJ06-1BB0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ06-1BB0
Reference: 7ME6820-2YJ06-1BB0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of line) Internal battery (battery not included)
Delivery: See availability
7ME6820-2YJ06-1DA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ06-1DA4
Reference: 7ME6820-2YJ06-1DA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 115/230 V AC Power with battery backup and 3m (9.8
Delivery: See availability
7MF8010-2QP31-3CC1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2QP31-3CC1
Reference: 7MF8010-2QP31-3CC1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...2,5 bar overload pressure: 10 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. NEUMO): 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: 0...2.5 bar Overload pressure: 16 bar No explosion protection
Delivery: See availability
7MF8010-2QP31-5BE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2QP31-5BE2
Reference: 7MF8010-2QP31-5BE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...600 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. NEUMO): 2 inches Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...600 mbar Overload pressu
Delivery: See availability
7MF8010-2VN31-2FA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2VN31-2FA2
Reference: 7MF8010-2VN31-2FA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, with screw necks W501: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: -1...0 bar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, with W501 threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut Measuring range: -1...0 bar Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2
Delivery: See availability
7ME6820-2YJ06-2NC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ06-2NC0
Reference: 7ME6820-2YJ06-2NC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery (Battery not included)
Delivery: See availability
7MF8010-2VP31-3DA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2VP31-3DA2
Reference: 7MF8010-2VP31-3DA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, with screw necks W501: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...10 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, with W501 threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. NEUMO): 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. measuring range: 0...10 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a
Delivery: See availability
7MF8010-2VP31-4CE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2VP31-4CE2
Reference: 7MF8010-2VP31-4CE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, with screw necks W501: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...6 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, with W501 threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. NEUMO): 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...6 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx
Delivery: See availability
7ME6820-2YJ42-1LD4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ42-1LD4
Reference: 7ME6820-2YJ42-1LD4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus 115/230 V AC protocol for p
Delivery: See availability
7ME6820-2YJ42-1ND4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ42-1ND4
Reference: 7ME6820-2YJ42-1ND4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus 115/230 V AC protocol for po
Delivery: See availability
7ML5632-8CG20-1GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CG20-1GC0
Reference: 7ML5632-8CG20-1GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III
Delivery: See availability
7ML5632-8CH30-1GD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CH30-1GD0
Reference: 7ML5632-8CH30-1GD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr. A, B, C, D, E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1350 mm (53.15") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4
Delivery: See availability
7ME6820-2YC03-1LT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1LT0
Reference: 7ME6820-2YC03-1LT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and analog cable(2.5m) Internal battery (battery not
Delivery: See availability
7ME6820-2YC03-1ND4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1ND4
Reference: 7ME6820-2YC03-1ND4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Q3/Q1 = 80 MI-001 verification Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 20 m (65.6) on the sensor with IP68/NEMA6P 6-pole connectors Transmitter interface module for ITRON 200WP Radio with Sensus 115/230 V AC Power Protocol with
Delivery: See availability
7ME6820-2YJ47-1CD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange,..

SIEMENS

Manufacturer Code: 7ME6820-2YJ47-1CD0
Reference: 7ME6820-2YJ47-1CD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (b
Delivery: See availability
7MF8010-2WM31-4BC1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2WM31-4BC1
Reference: 7MF8010-2WM31-4BC1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, clamp-connection W601: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...250 mbar overload pressure: 1 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, W601 clamp connection: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with grommet, IP65 (small measuring range: 0...250 mbar Overload pressure: 2 bar No explosion protection
Delivery: See availability
7ME6820-2YJ43-1AA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-1AA3
Reference: 7ME6820-2YJ43-1AA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors No Additional Communication Module Installed 12/24V AC/DC Power with Battery Backup and 3m Power Cable ( 9.8 ft) for external connection (without bat
Delivery: See availability
7ME6820-2YJ43-1DT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-1DT0
Reference: 7ME6820-2YJ43-1DT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) Internal batt
Delivery: See availability
7ME6820-2YJ43-2DB4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-2DB4
Reference: 7ME6820-2YJ43-2DB4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (Terminated 115/230 V AC power with battery backup a
Delivery: See availability
7ME6820-2YJ44-1ES1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-1ES1
Reference: 7ME6820-2YJ44-1ES1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) Built-in internal battery
Delivery: See availability
7ME6820-2YC00-2CB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-2CB1
Reference: 7ME6820-2YC00-2CB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (Terminated Built-in internal battery
Delivery: See availability
7ME6820-2YJ44-2LS1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-2LS1
Reference: 7ME6820-2YJ44-2LS1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=160 MI-001 Verification Regional Specific Version: US (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) Built-in internal battery
Delivery: See availability
7ME6820-2YC00-2PT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-2PT2
Reference: 7ME6820-2YC00-2PT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) External battery with 1.5 m (4
Delivery: See availability
7ME6820-2YC02-1BS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC02-1BS2
Reference: 7ME6820-2YC02-1BS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1=63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) External battery with 1.5 m (4.9 ft) connection cable with
Delivery: See availability
7ME6820-2YC02-1KC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC02-1KC2
Reference: 7ME6820-2YC02-1KC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor RS 232 Serial Port with MODBUS RTU External Battery with 1.5 m (4.9 ft) Connection Cable with IP68/NEMA 6P Connectors, Battery not included
Delivery: See availability
7ME6820-2YC02-2DA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC02-2DA4
Reference: 7ME6820-2YC02-2DA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 115/230 V AC Power with battery backup and 3m (9.8 ft) power
Delivery: See availability
7ME6820-2YC02-2MA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC02-2MA1
Reference: 7ME6820-2YC02-2MA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7ME6820-2YC03-1BA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1BA3
Reference: 7ME6820-2YC03-1BA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24V Power AC/DC with battery backup and 3m (9.8 ft) power
Delivery: See availability
7ME6820-2YJ45-2AS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ45-2AS2
Reference: 7ME6820-2YJ45-2AS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) External Battery with 1.5m (4.9ft) Connection Cable with IP68/NEMA 6P connectors, battery not includ
Delivery: See availability
7ME6820-2YJ45-2ET4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ45-2ET4
Reference: 7ME6820-2YJ45-2ET4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) 115/230 V AC po
Delivery: See availability
7ME6820-2YJ46-1KA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ46-1KA3
Reference: 7ME6820-2YJ46-1KA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor No Additional Communication Module Installed 12/24V AC/DC Power with Battery Backup and 3m Power Cable ( 9.8 ft) for external connection (without
Delivery: See availability
7ME6820-2YJ46-1MA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ46-1MA3
Reference: 7ME6820-2YJ46-1MA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24 Power V AC/DC with battery backu
Delivery: See availability
7ME6820-2YJ46-2ET0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ46-2ET0
Reference: 7ME6820-2YJ46-2ET0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) Internal batter
Delivery: See availability
7ME6820-2YJ46-2LD3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ46-2LD3
Reference: 7ME6820-2YJ46-2LD3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Encoder Interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol 12/24 V AC/DC power supp
Delivery: See availability
7ML5632-8DC00-1GD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DC00-1GD0
Reference: 7ML5632-8DC00-1GD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 350 mm (13.78") Thermal insulator: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epox
Delivery: See availability
7ME6820-2YC07-1BD4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC07-1BD4
Reference: 7ME6820-2YC07-1BD4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Q3/Q1 = 100 MI-001 vérification Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transmitter interface module for ITRON 200WP Radio with Sensus 115/230 V AC Power Protocol with Battery B
Delivery: See availability
7ME6820-2YC07-2BA2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC07-2BA2
Reference: 7ME6820-2YC07-2BA2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Wired External Battery 1.5 m (4.9 ft) connection with IP68/NEMA
Delivery: See availability
7ME6820-2YN02-2EB2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN02-2EB2
Reference: 7ME6820-2YN02-2EB2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: AS4087:PN 16 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1=63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Line Termination) External battery with 1.5 m (4.9 ft) connection c
Delivery: See availability
7ME6820-2YN02-2LB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN02-2LB1
Reference: 7ME6820-2YN02-2LB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: AS4087: PN 16 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Line Termination) Built-in internal battery
Delivery: See availability
7ME6820-2YN02-2NA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN02-2NA3
Reference: 7ME6820-2YN02-2NA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: AS4087:PN 16 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24V AC/ Power DC with battery backup and 3m (9.8 ft)
Delivery: See availability
7ML5632-8CJ00-0JD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CJ00-0JD0
Reference: 7ML5632-8CJ00-0JD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1500 mm (59.06") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CSA, FM, CE, UKCA, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 1500 mm (59.06") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ML5632-8CJ01-0GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CJ01-0GB0
Reference: 7ML5632-8CJ01-0GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1500 mm (59.06") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr. A, B, C, D, E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1500 mm (59.06") Thermal insulation: Without thermal insulation Seals on process side: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Cl
Delivery: See availability
7ML5632-8CJ10-1KC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CJ10-1KC0
Reference: 7ML5632-8CJ10-1KC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1500 mm (59.06") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose CSA, FM, CE, UKCA, RCM with WHG approval Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1500 mm (59.06") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68
Delivery: See availability
7ME6820-2YC04-1LA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-1LA3
Reference: 7ME6820-2YC04-1LA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24V Power AC/DC with battery backup and 3m (9.8 ft) po
Delivery: See availability
7ML5632-8CK10-1GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CK10-1GA0
Reference: 7ML5632-8CK10-1GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1750 mm (68.90") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1750 mm (68.90") Thermal insulator: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA
Delivery: See availability
7ME6820-2YC05-1BD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YC05-1BD0
Reference: 7ME6820-2YC05-1BD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery not inc
Delivery: See availability
7ME6820-2YC05-1KC3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC05-1KC3
Reference: 7ME6820-2YC05-1KC3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor Seriel RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Q3/Q1 = 200 MI-001 verification Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Advanced version integrated in the sensor RS 232 serial port with MODBUS RTU 12/24 V AC/DC power supply with battery backup and 3m power cable ( 9.8 ft) for external connection (without battery)
Delivery: See availability

products sitemap