SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7MF8010-2AD31-3BC2 SIEMENS Compact pressure transmitter, with separate tubular seal, for the food, pharmaceu..

SIEMENS

Manufacturer Code: 7MF8010-2AD31-3BC2
Reference: 7MF8010-2AD31-3BC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: in-line seal according DIN 11851 with screw necks: DN 25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...250 mbar overload pressure: 1 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick closures: Sanitary connection according to DIN 11851 with threaded nozzle: DN 25 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: 0...250 mbar Overload pressure: 2 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YJ04-1PD2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ04-1PD2
Reference: 7ME6820-2YJ04-1PD2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Encoder Interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol External battery with
Delivery: See availability
7ME6820-2YJ04-2BC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ04-2BC0
Reference: 7ME6820-2YJ04-2BC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery (Battery not included)
Delivery: See availability
7ME6820-2YC46-2MT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC46-2MT2
Reference: 7ME6820-2YC46-2MT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) External battery
Delivery: See availability
7ME6820-2YC46-2PT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC46-2PT0
Reference: 7ME6820-2YC46-2PT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) Internal battery
Delivery: See availability
7ME6820-2YC47-2BA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC47-2BA4
Reference: 7ME6820-2YC47-2BA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 115/230V AC Power supply with battery backup and 3m (
Delivery: See availability
7MF8010-2QN31-2ED2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2QN31-2ED2
Reference: 7MF8010-2QN31-2ED2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: -400...0 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. PNEUMO): 1 1/2 in. Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut Measuring range: -400...0 mbar Overload pressure: 6 bar Explosion protection according to ATEX 100
Delivery: See availability
7ME6820-2YJ05-2BS0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2BS0
Reference: 7ME6820-2YJ05-2BS0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) Internal battery (battery not included)
Delivery: See availability
7ME6820-2YJ05-2KC3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2KC3
Reference: 7ME6820-2YJ05-2KC3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor Seriel RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor RS 232 Serial Port with MODBUS RTU 12/24V AC/DC Power Supply with Battery Backup and 3m Power Cable ( 9.8 ft) for external connection (without battery)
Delivery: See availability
7ML5632-8EG30-0GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8EG30-0GA0
Reference: 7ML5632-8EG30-0GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 3" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 3" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4
Delivery: See availability
7ME6820-2YJ42-1DC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ42-1DC2
Reference: 7ME6820-2YJ42-1DC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU External Battery with 1.5 m (4.9 ft) patch cord with
Delivery: See availability
7MF8010-2WN31-3GB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2WN31-3GB2
Reference: 7MF8010-2WN31-3GB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, clamp-connection W601: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: -1...15 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, W601 clamp connection: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 1/2 in. Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: –1...15 bar Overload pressure: 50 bar Explosion protection according to ATEX 100 a,
Delivery: See availability
7ME6820-2YJ42-2NB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ42-2NB3
Reference: 7ME6820-2YJ42-2NB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: US (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (Terminated 12/24 V AC/DC power supply with batter
Delivery: See availability
7ME6820-2YJ43-1CA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-1CA1
Reference: 7ME6820-2YJ43-1CA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7MF8010-1EM31-5CC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1EM31-5CC2
Reference: 7MF8010-1EM31-5CC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: IDF-Norm with slotted union nut : 1 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...2,5 bar overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: IDF Standard with Fitting Nut: 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...2.5 bar Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC00-1AT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-1AT2
Reference: 7ME6820-2YC00-1AT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 No verification according to OIML R 49 Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: In integrated basic version sensors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) External battery with connection cable 1.5 m (4.9 ft) with IP68/NEMA 6P connectors,
Delivery: See availability
7ME6820-2YJ44-1CS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-1CS2
Reference: 7ME6820-2YJ44-1CS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) External battery with 1.5 m (4.9 ft) c
Delivery: See availability
7ME6820-2YJ44-1LD4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-1LD4
Reference: 7ME6820-2YJ44-1LD4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus 115/230 V AC protocol for po
Delivery: See availability
7MF8010-1EP31-5EE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1EP31-5EE2
Reference: 7MF8010-1EP31-5EE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: IDF-Norm with slotted union nut : 2 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -600...0 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: IDF Standard with Fitting Nut:: 2 inches Filling Fluid: FDA Listed Food Output Signal: 4-20 mA Box Version (Stainless Steel 1.4404)/Electrical Connection: Stainless Steel Field Box with Grommet, IP67(Small) (Indoor Venting for Measurement Ranges Less Than 10 Bar Measurement Range: -600...0 mbar Overload pressure: 6 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC00-1LS0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange,..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-1LS0
Reference: 7ME6820-2YC00-1LS0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Standard Calibration (No Initial Verification) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m Fixed Cable (16.
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) Internal battery (battery not included)
Delivery: See availability
7ME6820-2YC00-2AB2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-2AB2
Reference: 7ME6820-2YC00-2AB2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On RS 485 Integrated Basic Version Sensors Standard with MODBUS RTU (with Line Termination) External Battery with 1.5 m (4.9 ft) Connection Cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6820-2YC00-2MT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-2MT2
Reference: 7ME6820-2YC00-2MT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) External battery with 1.5 m (4
Delivery: See availability
7ME6820-2YJ44-2NT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange,..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-2NT0
Reference: 7ME6820-2YJ44-2NT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20m (65.5m) Internal Battery (Battery Not Included).
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=160 MI-001 Verification Regional Specific Version: US (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) Internal
Delivery: See availability
7ME6820-2YJ45-1NS4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ45-1NS4
Reference: 7ME6820-2YJ45-1NS4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 20m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) 115/230V AC power with batter
Delivery: See availability
7ME6340-5DB13-2HB1 SIEMENS SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN..

SIEMENS

Manufacturer Code: 7ME6340-5DB13-2HB1
Reference: 7ME6340-5DB13-2HB1
Catalog Number: -
SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN300, 12 Inch EN 1092-1, PN 10 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE max 150°C (302°F) Hastelloy C without grounding electrodes MAG 6000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 11-30V DC/11-24V AC 50/60 Hz HART Metric cable glands, Polyamid terminal box or MAG 6000i integral mount
SITRANS FM MAG 3100 Extremely precise electromagnetic flow sensor, with flange, diameter from DN 15 to DN 300 (from 1/2" to 12"). Suitable for continuous volumetric flow measurement of liquids (conductors), it is primarily used in the chemical industry, process industry, pulp and paper, water and wastewater. . Nominal diameter: DN 300 (12") Flange and nominal pressure standard: EN 1092-1: PN 10 (DN 200... 300 (8"… 12")) ASTM A 105 carbon steel flanges, corrosion resistant coating category C4 Coating material: PTFE max 150°C (302°F) Hastelloy C without grounding electrodes Transmitter with indicator: MAG 6000 I, polyamide, 11 - 30 V DC/ 11 - 24 V AC Communication: HART Metric cable gland, polyamide terminal box or compact MAG 6000i
Delivery: See availability
7MF8010-2AG31-2BD2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2AG31-2BD2
Reference: 7MF8010-2AG31-2BD2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: in-line seal according DIN 11851 with screw necks: DN 50 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: 0...400 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 50 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut measurement range: 0...400 mbar Overload pressure: 6 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2AG31-5HE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2AG31-5HE2
Reference: 7MF8010-2AG31-5HE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: in-line seal according DIN 11851 with screw necks: DN 50 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...6 bar abs. overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 50 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...6 bar abs. Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC48-1AD2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-1AD2
Reference: 7ME6820-2YC48-1AD2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor Encoder Interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Approval/verification: No verification according to OIML R 49 (Q3/Q1 = 250) Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: In sensors of integrated basic version Emitter interface module for ITRON 200WP Radio with Sensus Protocol External battery with cable 1.5 m (4.9
Delivery: See availability
7ME6820-2YC48-1CD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-1CD0
Reference: 7ME6820-2YC48-1CD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter and Mounting Type: Separate Basic Version, Fixed cable Do - 10 m (32.8) on the sensor with IP68/NEMA6P 6-pole connectors Transmitter interface module for ITRON 200WP Radio w
Delivery: See availability
7ME6820-2YC48-1LC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-1LC2
Reference: 7ME6820-2YC48-1LC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pin connectors RS 232 serial port with MODBUS RTU External battery with 1
Delivery: See availability
7ME6820-2YC48-1NC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-1NC0
Reference: 7ME6820-2YC48-1NC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pin connectors RS 232 serial port with MODBUS RTU Internal battery (b
Delivery: See availability
7ME6820-2YC48-2PT3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-2PT3
Reference: 7ME6820-2YC48-2PT3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) and a
Delivery: See availability
7MF8010-2VM31-2HA1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2VM31-2HA1
Reference: 7MF8010-2VM31-2HA1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, with screw necks W501: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: 0...1 bar abs. overload pressure: 3 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, with W501 threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 in. Filling fluid: FDA-listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut measurement range: 0...1 bar abs. Overload pressure: 3 bar No explosion protection
Delivery: See availability
7MF8010-2VM31-4FE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2VM31-4FE2
Reference: 7MF8010-2VM31-4FE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, with screw necks W501: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -1...5 bar overload pressure: 20 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, with W501 threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 in. Filling fluid: FDA-listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: -1...5 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx i
Delivery: See availability
7ME6820-2YJ07-1EA0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ07-1EA0
Reference: 7ME6820-2YJ07-1EA0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: ANSI B16.5: Class 150 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Q3/Q1 = 100 MI-001 vérification Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors No additional communication module installed Internal battery (battery not included)
Delivery: See availability
7MF8010-1GN31-5DC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1GN31-5DC2
Reference: 7MF8010-1GN31-5DC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: SMS-Norm with slotted union nut : 1 1 /2 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...25 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: SMS Standard with Fitting Nut: 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...25 bar Overload pressure: 50 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC04-1EA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-1EA4
Reference: 7ME6820-2YC04-1EA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 115/230 V AC Power with battery backup and 3m (9.8 ft) p
Delivery: See availability
7ME6820-2YJ47-2MT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ47-2MT0
Reference: 7ME6820-2YJ47-2MT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Advanced Version Separated, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) Inter
Delivery: See availability
7MF8010-1FN31-5CB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1FN31-5CB2
Reference: 7MF8010-1FN31-5CB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: IDF-Norm with screw necks: 1 1/2 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...1,6 bar overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: IDF Standard with Threaded Nozzle: 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...1.6 bar Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC02-1MB2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC02-1MB2
Reference: 7ME6820-2YC02-1MB2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of External battery with 1.5 m (4.9 ft) connectio
Delivery: See availability
7ME6820-2YC02-2KA2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC02-2KA2
Reference: 7ME6820-2YC02-2KA2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor No Additional Communication Module Installed External Battery with 1.5 m (4.9 ft) Patch Cord with IP68/NEMA 6P Connectors, Battery not included
Delivery: See availability
7ME6820-2YJ46-1PA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ46-1PA3
Reference: 7ME6820-2YJ46-1PA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24 Power V AC/DC with battery backu
Delivery: See availability
7ML5632-8CG20-1GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CG20-1GB0
Reference: 7ML5632-8CG20-1GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr. A, B, C, D, E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III
Delivery: See availability
7ML5632-8CG31-0HB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CG31-0HB0
Reference: 7ML5632-8CG31-0HB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8CH00-1GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CH00-1GB0
Reference: 7ML5632-8CH00-1GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr. A, B, C, D, E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1350 mm (53.15") Thermal insulation: Without thermal insulation Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coat
Delivery: See availability
7MF8010-1GM31-5FD2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1GM31-5FD2
Reference: 7MF8010-1GM31-5FD2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: SMS-Norm with slotted union nut : 1 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -1...3 bar overload pressure: 20 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: SMS Standard with Fitting Nut: 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar Measurement range: -1...3 bar Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC03-1DA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1DA1
Reference: 7ME6820-2YC03-1DA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7ME6820-2YC03-1KA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1KA1
Reference: 7ME6820-2YC03-1KA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7ME6820-2YC03-2CC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-2CC1
Reference: 7ME6820-2YC03-2CC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ47-1CC4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ47-1CC4
Reference: 7ME6820-2YJ47-1CC4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU 115/230 V AC power with battery backup and 3m (9.8
Delivery: See availability
7ME6820-2YC04-2BS3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-2BS3
Reference: 7ME6820-2YC04-2BS3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) 12/24V AC/DC power with battery backup and 3m (9.8 ft) po
Delivery: See availability
7ME6820-2YC04-2KD1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-2KD1
Reference: 7ME6820-2YC04-2KD1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor Encoder Interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Built-in Internal Battery
Delivery: See availability
7ME6820-2YC04-2MD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-2MD0
Reference: 7ME6820-2YC04-2MD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery not
Delivery: See availability
7ME6820-2YJ48-1KC4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ48-1KC4
Reference: 7ME6820-2YJ48-1KC4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor Seriel RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor RS 232 Serial Port with MODBUS RTU 115/230 V AC Power with Battery Backup and 3m (9.8 ft) power cord for externa
Delivery: See availability
7ME6820-2YJ48-2ES2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ48-2ES2
Reference: 7ME6820-2YJ48-2ES2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) Exte
Delivery: See availability
7ME6820-2YC05-2DA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC05-2DA3
Reference: 7ME6820-2YC05-2DA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24V Power AC/DC with battery backup and 3m (9.8 ft) powe
Delivery: See availability
7ME6820-2YC06-1AD1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-1AD1
Reference: 7ME6820-2YC06-1AD1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor Encoder Interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Built-in Internal Battery
Delivery: See availability
7ME6820-2YC06-2AB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-2AB1
Reference: 7ME6820-2YC06-2AB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: EN 1092-1:PN 16 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1=250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: On RS 485 Integrated Basic Version Sensors Standard with MODBUS RTU (with Line Termination) Built-in Internal Battery
Delivery: See availability
7ME6820-2YN00-2BD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN00-2BD0
Reference: 7ME6820-2YN00-2BD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery not included)
Delivery: See availability
7ME6820-2YN00-2MB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN00-2MB3
Reference: 7ME6820-2YN00-2MB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pin RS 485 Connectors Standard with MODBUS RTU (with Termination of 12/24 V AC/DC power with battery backup and 3m (9.8 ft)
Delivery: See availability
7ML5632-8DC00-1GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DC00-1GC0
Reference: 7ML5632-8DC00-1GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr. A, B, C, D, E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 350 mm (13.78") Thermal insulator: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epox
Delivery: See availability
7ML5632-8DC21-0GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DC21-0GA0
Reference: 7ML5632-8DC21-0GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 350 mm (13.78") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Cla
Delivery: See availability
7MF8010-1KL31-3HA1 SIEMENS Compact pressure transmitter, with flush membrane, for the food, pharmaceutical a..

SIEMENS

Manufacturer Code: 7MF8010-1KL31-3HA1
Reference: 7MF8010-1KL31-3HA1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company): d=68, for varivent- housing DN 40...DN 125, and 1 1/2 inch...6 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...1 bar abs. overload pressure: 3 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Varivent connection (Tuchenhagen brand): d = 68, for Varivent DN 40...DN 125 box, and 1 1/2 inches... 6 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: 0...1 bar ABS. Overload pressure: 3 bar No explosion protection
Delivery: See availability
7MF8010-1KL31-4FE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1KL31-4FE2
Reference: 7MF8010-1KL31-4FE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company): d=68, for varivent- housing DN 40...DN 125, and 1 1/2 inch...6 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -1...5 bar overload pressure: 20 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Varivent connection (Tuchenhagen brand): d = 68, for Varivent DN 40...DN 125 box, and 1 1/2 inches... 6 inches Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: -1...5 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1KL31-5FE1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1KL31-5FE1
Reference: 7MF8010-1KL31-5FE1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company): d=68, for varivent- housing DN 40...DN 125, and 1 1/2 inch...6 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -1...5 bar overload pressure: 20 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Varivent connection (Tuchenhagen brand): d = 68, for Varivent DN 40...DN 125 box, and 1 1/2 inches... 6 inch Filling Fluid: FDA Listed Food Output Signal: 4-20 mA Box Version (Stainless Steel 1.4404)/Electrical Connection: Stainless Steel Field Box with Grommet, IP67(Small) (Indoor Venting for Measurement Ranges Less Than 10 Bar Measurement Range: -1...5 bar Overload Pressure: 30 bar No Explosion Protection
Delivery: See availability
7MF8010-1PM31-4DC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PM31-4DC2
Reference: 7MF8010-1PM31-4DC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...25 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...25 bar Overload pressure: 50 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC07-2ES4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC07-2ES4
Reference: 7ME6820-2YC07-2ES4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) 115/230V AC power with battery backup and 3m (9.8 ft) p
Delivery: See availability
7ML5632-8DB00-1FC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DB00-1FC0
Reference: 7ML5632-8DB00-1FC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 250 mm (9.84") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/ FM Class II, III Div.1 Gr. E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 250 mm (9.84") Thermal insulator: Without thermal insulator Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry,
Delivery: See availability
7MF8010-1KF31-5BB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1KF31-5BB2
Reference: 7MF8010-1KF31-5BB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company) d= 50, for varivent housing DN 25 and 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...160 mbar overload pressure: 1 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process connection type: flush membrane with front/quick releases: Varivent connection (Tuchenhagen brand): d = 50, for Varivent DN 25 box and 1 inch Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with grommet, IP67(small) (indoor ventilation for measuring ranges less than 10 bar measuring range: 0...160 mbar Overload pressure: 2 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC06-2CA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-2CA4
Reference: 7ME6820-2YC06-2CA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 115/230 V AC Power with battery backup and 3m (9.8 ft) powe
Delivery: See availability
7ME6820-2YC06-2KT3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-2KT3
Reference: 7ME6820-2YC06-2KT3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Sensor Integrated Version 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and Analog Cable (2.5m) 12/24 V AC/DC Power with Backup 3m (9.8 ft) battery and power cord for external connection (
Delivery: See availability
7ME6820-2YN02-1ET0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN02-1ET0
Reference: 7ME6820-2YN02-1ET0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) and Analog Cable(2.5m) Internal Battery (Battery Not Inc
Delivery: See availability
7ML5632-8DD20-1GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DD20-1GC0
Reference: 7ML5632-8DD20-1GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 500 mm (19.69") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 500 mm (19.69") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Cla
Delivery: See availability
7MF8010-1PN31-2HD1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PN31-2HD1
Reference: 7MF8010-1PN31-2HD1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: 0...4 bar abs. overload pressure: 10 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 1/2 in. Filling fluid: FDA-listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut measurement range: 0...4 bar abs. Overload pressure: 16 bar No explosion protection
Delivery: See availability
7MF8010-1PN31-4FC1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PN31-4FC1
Reference: 7MF8010-1PN31-4FC1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -1...1,5 bar overload pressure: 10 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: -1...1.5 bar Overload pressure: 16 bar No explosion protection
Delivery: See availability
7MF8010-1PN31-5DB1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PN31-5DB1
Reference: 7MF8010-1PN31-5DB1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...16 bar overload pressure: 60 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...16 bar Overload pressure: 50 bar No explosion protection
Delivery: See availability
7ME6820-2YC08-1EB2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC08-1EB2
Reference: 7ME6820-2YC08-1EB2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors as Standard with MODBUS RTU (with line termination) External
Delivery: See availability
7ME6820-2YC40-1CT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC40-1CT0
Reference: 7ME6820-2YC40-1CT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 No verification according to OIML R 49 Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with cable Antenna(5m) and analog cable(2.5m) Internal ba
Delivery: See availability
7ME6820-2YC40-2AB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC40-2AB3
Reference: 7ME6820-2YC40-2AB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On RS 485 Integrated Basic Version Sensors Standard with MODBUS RTU (with Line Termination) 12/24 V AC/DC Power Supply with Battery Backup and 3m (9.8 ft) power cord for external connection (with
Delivery: See availability

products sitemap