SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7MF8010-1XB31-4HD2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1XB31-4HD2
Reference: 7MF8010-1XB31-4HD2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm male thread acc. DIN 3852, form A, G 3/4 inch, minimum measuring span 1 bar Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...4 bar abs. overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Connections with Front Connection Nozzle for Thread according to DIN 3852, Form A, G 3/4 in., minimum measurement range 1 bar Filling Fluid: FDA Listed Food Output Signal: 4-20 mA Box Version (Stainless Steel 1.4404)/Electrical Connection: Stainless Steel Field Box with Grommet, IP65 (small measurement range: 0...4 bar abs. Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC44-2CS0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-2CS0
Reference: 7ME6820-2YC44-2CS0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) Internal battery (battery not included)
Delivery: See availability
7ME6820-2YC44-2EC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-2EC1
Reference: 7ME6820-2YC44-2EC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery Incorporated
Delivery: See availability
7ME6820-2YC44-2LB4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-2LB4
Reference: 7ME6820-2YC44-2LB4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Version Separated, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (Terminated 115/230 V AC power with battery backup and 3m (9.8
Delivery: See availability
7ME6820-2YC45-1DD3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC45-1DD3
Reference: 7ME6820-2YC45-1DD3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder Interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol 12/24 V AC/DC power supply w
Delivery: See availability
7MF8010-2AH31-5FD1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2AH31-5FD1
Reference: 7MF8010-2AH31-5FD1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: in-line seal according DIN 11851 with screw necks: DN 60 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -1...3 bar overload pressure: 20 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 65 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measuring ranges less than 10 bar Measuring range: -1...3 bar Overload pressure: 16 bar No explosion protection
Delivery: See availability
7ME6820-2YJ00-1MC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ00-1MC0
Reference: 7ME6820-2YJ00-1MC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: ANSI B16.5: Class 150 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 No verification according to OIML R 49 Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors RS 232 serial port with MODBUS RTU Internal battery ( Battery not included)
Delivery: See availability
7ME6820-2YJ00-2LS0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ00-2LS0
Reference: 7ME6820-2YJ00-2LS0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) Internal battery (battery not included)
Delivery: See availability
7ME6820-2YJ02-1AB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ02-1AB3
Reference: 7ME6820-2YJ02-1AB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: On RS 485 Integrated Basic Version Sensors Standard with MODBUS RTU (with Line Termination) 12/24 V AC/DC Power with Battery and Cable Backup 3m (9.8 ft) power for external connection (without ba
Delivery: See availability
7MF8010-1AG31-4DC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1AG31-4DC2
Reference: 7MF8010-1AG31-4DC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with slotted union nut: DN 50 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...25 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Sanitary connection according to DIN 11851 with Fitting nut: DN 50 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...25 bar Overload pressure: 50 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2CF31-3HB2 SIEMENS Compact pressure transmitter, with separate tubular seal, for the food, pharmaceu..

SIEMENS

Manufacturer Code: 7MF8010-2CF31-3HB2
Reference: 7MF8010-2CF31-3HB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according DIN 32676: DN 40 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...1,6 bar abs. overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Clamp connection according to DIN 32676: DN 40 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: 0...1.6 bar ABS. Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YJ02-2KD1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ02-2KD1
Reference: 7ME6820-2YJ02-2KD1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor Encoder Interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Built-in Internal Battery
Delivery: See availability
7MF8010-1BD31-3GA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1BD31-3GA2
Reference: 7MF8010-1BD31-3GA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with screw necks: DN 25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: -1...9 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 25 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: -1...9 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1BD31-5HA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1BD31-5HA2
Reference: 7MF8010-1BD31-5HA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with screw necks: DN 25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...1 bar abs. overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 25 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measuring ranges less than 10 bar measuring range: 0...1 bar abs. Overload pressure: 3 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1BE31-4JA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1BE31-4JA2
Reference: 7MF8010-1BE31-4JA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with screw necks: DN 32 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0... 10 bar abs. overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 32 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable protector, IP65 (small measuring range: 0...10 bar abs. Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2CH31-5BE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2CH31-5BE2
Reference: 7MF8010-2CH31-5BE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according DIN 32676: DN 65 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...600 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Clamp connection according to DIN 32676: DN 65 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (internal ventilation for measuring ranges less than 10 bar measuring range: 0...600 mbar Overload pressure: 6 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YJ03-2AS4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ03-2AS4
Reference: 7ME6820-2YJ03-2AS4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) 115/230 V AC Power with Battery Backup and Power Cable 3m (9.8 ft) for external connection (without battery)
Delivery: See availability
7ME6820-2YJ03-2CS3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange,..

SIEMENS

Manufacturer Code: 7ME6820-2YJ03-2CS3
Reference: 7ME6820-2YJ03-2CS3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8 ft) for External Connection (No Battery).
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1=80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) 12/24V AC/DC power with battery backup and 3m (9.8 ft
Delivery: See availability
7ME6820-2YJ03-2ES1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ03-2ES1
Reference: 7ME6820-2YJ03-2ES1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM & Hastelloy Electrode Coating, Corrosion Resistant Coating Category C4 Q3/Q1=80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Built-in internal battery
Delivery: See availability
7ME6820-2YJ04-2BB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ04-2BB1
Reference: 7ME6820-2YJ04-2BB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pin RS 485 Connectors Standard with MODBUS RTU (with Termination of Built-in internal battery
Delivery: See availability
7ML5632-8EF00-1FA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8EF00-1FA0
Reference: 7ML5632-8EF00-1FA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 3" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 3" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1000 mm (39.37") Thermal insulation: Without thermal insulation Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry
Delivery: See availability
7ML5632-8EG30-0FA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8EG30-0FA0
Reference: 7ML5632-8EG30-0FA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 3" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/ FM Class II, III Div.1 Gr. E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 3" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x
Delivery: See availability
7ME6340-5DB13-2AA3 SIEMENS SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN..

SIEMENS

Manufacturer Code: 7ME6340-5DB13-2AA3
Reference: 7ME6340-5DB13-2AA3
Catalog Number: -
SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN300, 12 Inch EN 1092-1, PN 10 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE max 150°C (302°F) Hastelloy C without grounding electrodes Sensor for remote transmitter (order transmitter separately) No bus communication Metric cable glands, Stainless steel terminal box (mandatory for stainless steel MAG 6000 transmitter)
SITRANS FM MAG 3100 Extremely precise electromagnetic flow sensor, with flange, diameter from DN 15 to DN 300 (from 1/2" to 12"). Suitable for continuous volumetric flow measurement of liquids (conductors), it is primarily used in the chemical industry, process industry, pulp and paper, water and wastewater. . Nominal diameter: DN 300 (12") Flange and nominal pressure standard: EN 1092-1: PN 10 (DN 200... 300 (8"… 12")) ASTM A 105 carbon steel flanges, corrosion resistant coating category C4 Coating material: PTFE max 150°C (302°F) Hastelloy C without grounding electrodes Transmitter with indicator: Sensor for separately mounted transmitter (order transmitter separately) No bus communication Presse-étoupes métrique, acier inoxydable boîte de connexion (obligatoire pour les transmetteurs
Delivery: See availability
7ME6820-2YC48-1CC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-1CC1
Reference: 7ME6820-2YC48-1CC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter and Mounting Type: Separate Basic Version, Fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors RS 232 serial port with MODBUS RTU Built-in internal bat
Delivery: See availability
7ME6820-2YC48-1EC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-1EC0
Reference: 7ME6820-2YC48-1EC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter and Mounting Type: Separate Basic Version, Fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors RS 232 serial port with MODBUS RTU Internal battery (bat
Delivery: See availability
7ME6820-2YC48-2PS4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-2PS4
Reference: 7ME6820-2YC48-2PS4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) 115/23
Delivery: See availability
7MF8010-1AD31-3HE2 SIEMENS Compact pressure transmitter, with flush membrane, for the food, pharmaceutical a..

SIEMENS

Manufacturer Code: 7MF8010-1AD31-3HE2
Reference: 7MF8010-1AD31-3HE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with slotted union nut: DN 25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...6 bar abs. overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick closures: Sanitary connection according to DIN 11851 with Fitting nut: DN 25 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with round connector M12 IP65 Stainless steel fixing fitting nut. Measuring range: 0...6 bar ABS. Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2QM31-4EE2 SIEMENS Compact pressure transmitter, with separate tubular seal, for the food, pharmaceu..

SIEMENS

Manufacturer Code: 7MF8010-2QM31-4EE2
Reference: 7MF8010-2QM31-4EE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -600...0 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. PNEUMO): 1 in. Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: -600...0 mbar Overload pressure: 6 bar Explosion protection according to ATEX 100 a, II 2 G
Delivery: See availability
7MF8010-2QM31-5EE1 SIEMENS Compact pressure transmitter, with separate tubular seal, for the food, pharmaceu..

SIEMENS

Manufacturer Code: 7MF8010-2QM31-5EE1
Reference: 7MF8010-2QM31-5EE1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -600...0 mbar overload pressure: 3 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. PNEUMO): 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar Measurement range: -600...0 mbar Overload pressur
Delivery: See availability
7MF8010-2QN31-4DC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2QN31-4DC2
Reference: 7MF8010-2QN31-4DC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...25 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. PNEUMO): 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...25 bar Overload pressure: 50 bar Explosion protection according to ATEX 100 a, II 2
Delivery: See availability
7ME6820-2YJ05-2MB0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2MB0
Reference: 7ME6820-2YJ05-2MB0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of line) Internal battery (battery not i
Delivery: See availability
7ME6820-2YJ05-2PB0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange,..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2PB0
Reference: 7ME6820-2YJ05-2PB0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of line) Internal battery (battery not in
Delivery: See availability
7MF8010-2VM31-4FC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2VM31-4FC2
Reference: 7MF8010-2VM31-4FC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, with screw necks W501: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -1...1,5 bar overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, with W501 threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: -1...1.5 bar Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2 G, EEx
Delivery: See availability
7ME6820-2YJ07-1AB0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YJ07-1AB0
Reference: 7ME6820-2YJ07-1AB0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: On RS 485 Integrated Basic Version Sensors as Standard with MODBUS RTU (with Line Termination) Internal Battery (Battery Not Included)
Delivery: See availability
7ME6820-2YJ04-2ET3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange,..

SIEMENS

Manufacturer Code: 7ME6820-2YJ04-2ET3
Reference: 7ME6820-2YJ04-2ET3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM & Hastelloy Electrode Coating, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.8 ft) for External Connection (No Battery).
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) and analog cable (2.5m) 12/24V AC/DC power supply
Delivery: See availability
7ME6820-2YJ04-2NC4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ04-2NC4
Reference: 7ME6820-2YJ04-2NC4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU 115/230 V AC Power supply with battery backup and 3m (9.8 ft)
Delivery: See availability
7ME6820-2YJ43-1BT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-1BT2
Reference: 7ME6820-2YJ43-1BT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) External battery
Delivery: See availability
7ME6820-2YJ43-1KS0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-1KS0
Reference: 7ME6820-2YJ43-1KS0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Internal Battery (Battery Not Included)
Delivery: See availability
7ME6820-2YJ43-1PB4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-1PB4
Reference: 7ME6820-2YJ43-1PB4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Separated, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (Terminated 115/230 V AC power with battery backup a
Delivery: See availability
7MF8010-1EP31-5EC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1EP31-5EC2
Reference: 7MF8010-1EP31-5EC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: IDF-Norm with slotted union nut : 2 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -250...0 mbar overload pressure: 1 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: IDF Standard with Fitting Nut:: 2 inches Filling Fluid: FDA Listed Food Output Signal: 4-20 mA Box Version (Stainless Steel 1.4404)/Electrical Connection: Stainless Steel Field Box with Grommet, IP67(Small) (Indoor Venting for Measurement Ranges Less Than 10 Bar Measurement Range: -250...0 mbar Overload pressure: 2 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC00-2KT1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-2KT1
Reference: 7ME6820-2YC00-2KT1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Sensor Integrated Version 3G/UMTS Module for MAG8000 with Antenna Cable(5m) and Analog Cable(2.5m) Built-in Internal Battery
Delivery: See availability
7ME6820-2YC00-2MS3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-2MS3
Reference: 7ME6820-2YC00-2MS3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) 12/24V AC/DC power supply with battery backup and 3m
Delivery: See availability
7ME6820-2YJ44-2ED1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-2ED1
Reference: 7ME6820-2YJ44-2ED1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder Interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Built-in internal bat
Delivery: See availability
7ME6820-2YJ45-1NS0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ45-1NS0
Reference: 7ME6820-2YJ45-1NS0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 20m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) Internal battery (battery not
Delivery: See availability
7MF8010-2WM31-4HE1 SIEMENS Compact pressure transmitter, with separate tubular seal, for the food, pharmaceu..

SIEMENS

Manufacturer Code: 7MF8010-2WM31-4HE1
Reference: 7MF8010-2WM31-4HE1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, clamp-connection W601: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...6 bar abs. overload pressure: 60 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, W601 clamp connection: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measurement range: 0...6 bar abs. Overload pressure: 30 bar No explosion protection
Delivery: See availability
7ME6820-2YC02-1MA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC02-1MA3
Reference: 7ME6820-2YC02-1MA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24V Power AC/DC with battery backup and 3m (9.8 ft)
Delivery: See availability
7ME6820-2YC02-2AT4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC02-2AT4
Reference: 7ME6820-2YC02-2AT4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: In Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and Analog Cable (2.5m) 115/230 V AC Power Supply with Backup 3m (9.8 ft) battery and power cord for external connec
Delivery: See availability
7ME6820-2YJ46-1NT4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ46-1NT4
Reference: 7ME6820-2YJ46-1NT4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) 115/230 V
Delivery: See availability
7MF8010-1GM31-5FB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1GM31-5FB2
Reference: 7MF8010-1GM31-5FB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: SMS-Norm with slotted union nut : 1 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -1...0,6 bar overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: SMS Standard with Fitting Nut: 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar Measurement range: -1...0.6 bar Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1GN31-5DA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1GN31-5DA2
Reference: 7MF8010-1GN31-5DA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: SMS-Norm with slotted union nut : 1 1 /2 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...10 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: SMS Standard with Fitting Nut: 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...10 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC03-1CT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1CT2
Reference: 7ME6820-2YC03-1CT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and analog cable(2.5m) External battery with 1.5 m (
Delivery: See availability
7ME6820-2YC03-1ET2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1ET2
Reference: 7ME6820-2YC03-1ET2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) and analog cable(2.5m) External battery with 1.5 m (4.
Delivery: See availability
7ME6820-2YC03-1NC4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1NC4
Reference: 7ME6820-2YC03-1NC4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU 115/230 V AC Power supply with battery backup and 3m (9.8 ft) po
Delivery: See availability
7ME6820-2YC03-2AB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-2AB3
Reference: 7ME6820-2YC03-2AB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version RS 485 Sensors Standard with MODBUS RTU (with Line Termination) 12/24 V AC/DC Power with Battery and Cable Backup 3m (9.8 ft) power for external connection (without battery)
Delivery: See availability
7ME6820-2YC03-2CB2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-2CB2
Reference: 7ME6820-2YC03-2CB2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of External battery with 1.5 m (4.9 ft) connection cabl
Delivery: See availability
7ME6820-2YC03-2EB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-2EB1
Reference: 7ME6820-2YC03-2EB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of Built-in internal battery
Delivery: See availability
7ME6820-2YJ46-2NC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ46-2NC2
Reference: 7ME6820-2YJ46-2NC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Power Bank with 1.5 m (4.9 ft) patch cord with IP68/NEM
Delivery: See availability
7ME6820-2YJ47-1AC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ47-1AC1
Reference: 7ME6820-2YJ47-1AC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors RS 232 Serial Port with MODBUS RTU Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ47-1CC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ47-1CC0
Reference: 7ME6820-2YJ47-1CC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery ( Battery not included)
Delivery: See availability
7ML5632-8CJ01-0FB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CJ01-0FB0
Reference: 7ML5632-8CJ01-0FB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1500 mm (59.06") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/ FM Class II, III Div.1 Gr. E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1500 mm (59.06") Thermal insulation: Without thermal insulation Seals on process side: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy
Delivery: See availability
7ME6820-2YC04-1EA0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-1EA0
Reference: 7ME6820-2YC04-1EA0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Internal Battery (Battery No included)
Delivery: See availability
7ME6820-2YC04-1MT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-1MT2
Reference: 7ME6820-2YC04-1MT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and analog cable(2.5m) External battery with 1.
Delivery: See availability
7ME6820-2YC04-2KC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-2KC2
Reference: 7ME6820-2YC04-2KC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor RS 232 Serial Port with MODBUS RTU External Battery with 1.5 m (4.9 ft) Connection Cable with IP68/NEMA 6P Connectors, Battery not included
Delivery: See availability
7ME6820-2YC04-2MC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-2MC1
Reference: 7ME6820-2YC04-2MC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ48-1DC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ48-1DC2
Reference: 7ME6820-2YJ48-1DC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pin connectors RS 232 serial port with MODBUS RTU External battery
Delivery: See availability
7ME6820-2YC06-1CC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-1CC0
Reference: 7ME6820-2YC06-1CC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery (Battery not included)
Delivery: See availability
7ML5632-8DA31-0GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DA31-0GA0
Reference: 7ML5632-8DA31-0GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Alum
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Clas
Delivery: See availability
7MF8010-1KF31-4HE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1KF31-4HE2
Reference: 7MF8010-1KF31-4HE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company) d= 50, for varivent housing DN 25 and 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...6 bar abs. overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process connection type: flush membrane with front/quick releases: Varivent connection (Tuchenhagen brand): d = 50, for Varivent DN 25 box and 1 inch Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with grommet, IP65 (small measurement range: 0...6 bar abs. Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC06-2AA2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-2AA2
Reference: 7ME6820-2YC06-2AA2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors No Additional Communication Module Installed External Battery with 1.5 m (4.9 ft) Patch Cord with IP68/NEMA 6P Connectors, Battery not included
Delivery: See availability
7ME6820-2YC06-2CA0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-2CA0
Reference: 7ME6820-2YC06-2CA0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Internal Battery (Battery No included)
Delivery: See availability
7ME6820-2YC06-2MD3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-2MD3
Reference: 7ME6820-2YC06-2MD3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Encoder Interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol 12/24 V AC/DC power supply wi
Delivery: See availability
7ME6820-2YC07-1DC3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC07-1DC3
Reference: 7ME6820-2YC07-1DC3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU 12/24 Power V AC/DC with battery backup and 3m (9.8 ft) power cabl
Delivery: See availability
7ME6820-2YN02-1CS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow se..

SIEMENS

Manufacturer Code: 7ME6820-2YN02-1CS2
Reference: 7ME6820-2YN02-1CS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated, flange-operated, electromagnetic flow sensor diameter from DN 25 to DN 1200 (from 1" to 48"), approved for verified transactions. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Battery Exter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Battery External with 1.5 m (4.9 ft) connection cable wit
Delivery: See availability
7ML5632-8DD30-1HB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DD30-1HB0
Reference: 7ML5632-8DD30-1HB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 500 mm (19.69") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 500 mm (19.69") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability

products sitemap