SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7MF8010-1KL31-4FB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1KL31-4FB2
Reference: 7MF8010-1KL31-4FB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company): d=68, for varivent- housing DN 40...DN 125, and 1 1/2 inch...6 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -1...0,6 bar overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Varivent connection (Tuchenhagen brand): d = 68, for Varivent DN 40...DN 125 box, and 1 1/2 inches... 6 inches Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: -1...0.6 bar Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1KL31-5FB1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1KL31-5FB1
Reference: 7MF8010-1KL31-5FB1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company): d=68, for varivent- housing DN 40...DN 125, and 1 1/2 inch...6 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -1...0,6 bar overload pressure: 10 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Varivent connection (Tuchenhagen brand): d = 68, for Varivent DN 40...DN 125 box, and 1 1/2 inches... 6 inch Filling Fluid: FDA Listed Food Output Signal: 4-20 mA Box Version (1.4404 Stainless Steel)/Electrical Connection: Stainless Steel Field Box with Grommet, IP67(Small) (Indoor Venting for Measurement Ranges Less Than 10 Bar Measurement Range: -1...0.6 bar Overload Pressure: 10 bar No Explosion Protection
Delivery: See availability
7MF8010-1PM31-4CE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PM31-4CE2
Reference: 7MF8010-1PM31-4CE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...6 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...6 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC07-2ED3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC07-2ED3
Reference: 7ME6820-2YC07-2ED3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder Interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Q3/Q1 = 100 MI-001 vérification Regional specific version: USA (m3, m3/h, 60 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on the sensor with IP68/NEMA6P 6-pole connectors Transmitter interface module for ITRON 200WP Radio with Sensus Protocol 12/24 V AC/DC power supply w
Delivery: See availability
7ME6820-2YC08-1EA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC08-1EA1
Reference: 7ME6820-2YC08-1EA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors No Communication Module Additional installed Built-in internal batt
Delivery: See availability
7MF8010-1PN31-2HA1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PN31-2HA1
Reference: 7MF8010-1PN31-2HA1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: 0...1 bar abs. overload pressure: 3 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 1/2 in. Filling fluid: FDA-listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut measurement range: 0...1 bar abs. Overload pressure: 3 bar No explosion protection
Delivery: See availability
7MF8010-1PN31-4EE1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PN31-4EE1
Reference: 7MF8010-1PN31-4EE1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -600...0 mbar overload pressure: 3 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with grommet, IP65 (small Measuring range: -600...0 mbar Overload pressure: 6 bar No explosion protection
Delivery: See availability
7ME6820-2YC40-1CD4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC40-1CD4
Reference: 7ME6820-2YC40-1CD4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 No Verification to OIML R 49 Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Sensus Protocol Radio 115/230 V AC Power with Battery
Delivery: See availability
7ML5632-8DF10-0JD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DF10-0JD0
Reference: 7ML5632-8DF10-0JD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CSA, FM, CE, UKCA, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulator: With thermal insulator (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7MF8010-1PP31-4HE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PP31-4HE2
Reference: 7MF8010-1PP31-4HE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...6 bar abs. overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. ext. in inches BS 4825 part 1 (not for NEUMO) : 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...6 bar abs. Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1PQ31-4FE1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PQ31-4FE1
Reference: 7MF8010-1PQ31-4FE1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 2 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -1...5 bar overload pressure: 20 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 2 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: -1...5 bar Overload pressure: 30 bar No explosion protection
Delivery: See availability
7MF8010-1PQ31-5FD1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PQ31-5FD1
Reference: 7MF8010-1PQ31-5FD1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 2 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -1...3 bar overload pressure: 20 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 2 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar Measurement range: -1...3 bar Overload pressure: 16 bar No explosion protection
Delivery: See availability
7ME6820-2YC42-1BC3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC42-1BC3
Reference: 7ME6820-2YC42-1BC3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Power Supply 12/24V AC/DC with battery backup and 3m (9.8 ft)
Delivery: See availability
7ME6820-2YC42-1KB0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC42-1KB0
Reference: 7ME6820-2YC42-1KB0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated into RS 485 Sensor Standard with MODBUS RTU (with Line Termination) Internal Battery (Battery Not Included)
Delivery: See availability
7ME6820-2YC42-1MA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC42-1MA4
Reference: 7ME6820-2YC42-1MA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 115/230 V AC Power supply with battery backu
Delivery: See availability
7ME6820-2YC42-2BA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC42-2BA1
Reference: 7ME6820-2YC42-2BA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7ME6820-2YC42-2CT3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC42-2CT3
Reference: 7ME6820-2YC42-2CT3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable (2.5m) 12/24V AC/DC power s
Delivery: See availability
7ME6820-2YC43-1AB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC43-1AB3
Reference: 7ME6820-2YC43-1AB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: On RS 485 Integrated Basic Version Sensors Standard with MODBUS RTU (with Line Termination) 12/24 V AC/DC Power Supply with Battery Backup and 3m (9.8 ft) power cord for external connection
Delivery: See availability
7ML5632-8DH10-0FB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DH10-0FB0
Reference: 7ML5632-8DH10-0FB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/ FM Class II, III Div.1 Gr. E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 1350 mm (53.15") Thermal insulator: With thermal insulator (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Li
Delivery: See availability
7ME6820-2YC43-2KC4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC43-2KC4
Reference: 7ME6820-2YC43-2KC4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor Seriel RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Q3/Q1 = 80 MI-001 verification Regional specific version: USA (m3, m3/h, 60 Hz) Transmitter type and mounting: Advanced version integrated in the sensor RS 232 serial port with MODBUS RTU 115/230 V AC power with battery backup and 3m power cable ( 9.8 ft) for external connection (without battery)
Delivery: See availability
7ME6820-2YC44-1BB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-1BB1
Reference: 7ME6820-2YC44-1BB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Terminating Built-in internal battery
Delivery: See availability
7ML5632-8DH20-0FC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DH20-0FC0
Reference: 7ML5632-8DH20-0FC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/ FM Class II, III Div.1 Gr..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1350 mm (53.15") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coate
Delivery: See availability
7ML5632-8DK10-1JB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DK10-1JB0
Reference: 7ML5632-8DK10-1JB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1750 mm (68.90") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM, CE, UKCA, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 1750 mm (68.90") Thermal insulator: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8DL01-0CB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DL01-0CB0
Reference: 7ML5632-8DL01-0CB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, UKCA, RCM, ATEX, UKEX II 1/2D Ex ia/tb Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulation: Without thermal insulation Seals on process side: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7MF8010-1XA31-4FD2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1XA31-4FD2
Reference: 7MF8010-1XA31-4FD2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm male thread acc. DIN 3852, form A, G 1/2 inch, minimum measuring span 1.6 bar Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -1...3 bar overload pressure: 20 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process connection type: Flush connections with front Connection nozzle for Thread according to DIN 3852, Form A, G 1/2 inch, minimum measurement range 1.6 bar Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: -1...3 bar Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC44-1DA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-1DA4
Reference: 7ME6820-2YC44-1DA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 115/230 V AC Power supply with battery backup
Delivery: See availability
7ME6820-2YC44-1KA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-1KA3
Reference: 7ME6820-2YC44-1KA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Q3/Q1 = 160 MI-001 verification Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Advanced version integrated in the sensor No additional communication module installed 12/24 V AC/DC power supply with battery backup and 3m power cable ( 9.8 ft) for external connection (w
Delivery: See availability
7ME6820-2YC44-1NS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-1NS2
Reference: 7ME6820-2YC44-1NS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) External battery with 1.5 m (4.9 ft)
Delivery: See availability
7ME6820-2YC44-2CD3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-2CD3
Reference: 7ME6820-2YC44-2CD3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Encoder Interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol 12/24 V AC/DC power supply
Delivery: See availability
7ML5632-8EA21-0HC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8EA21-0HC0
Reference: 7ML5632-8EA21-0HC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 3" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 3" Sanitary Clamp Special Version: (length measured from process connection face): Compact design 98 mm (3.86") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Seals on process side: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe Approvals: General Purpose (CSA, FM) Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68
Delivery: See availability
7ML5632-8EB00-1HD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8EB00-1HD0
Reference: 7ML5632-8EB00-1HD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 3" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 250 mm (9.84") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 3" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 250 mm (9.84") Thermal insulator: Without thermal insulator Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ME6820-2YC45-2LS3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC45-2LS3
Reference: 7ME6820-2YC45-2LS3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) 12/24V AC/DC power supply with battery backu
Delivery: See availability
7ME6820-2YC45-2ND0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC45-2ND0
Reference: 7ME6820-2YC45-2ND0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6 Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (batter
Delivery: See availability
7ME6820-2YC46-1CC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC46-1CC1
Reference: 7ME6820-2YC46-1CC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery Incorporated
Delivery: See availability
7ML5632-8EB21-0GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8EB21-0GB0
Reference: 7ML5632-8EB21-0GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 3" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 250 mm (9.84") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr.5 cable inlet, IP65 ..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 3" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 250 mm (9.84") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class I
Delivery: See availability
7ML5632-8EC21-0GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8EC21-0GA0
Reference: 7ML5632-8EC21-0GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 3" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 3" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 350 mm (13.78") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat. no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class
Delivery: See availability
7MF8010-1XE31-2EC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1XE31-2EC2
Reference: 7MF8010-1XE31-2EC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm male thread acc. DIN 3852, form A, G 2 inch, minimum measuring span 0.16 bar Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: -250...0 mbar overload pressure: 1 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: Flush connections with front Connection nozzle for Thread according to DIN 3852, Form A, G 2 inches, minimum measurement range 0.16 bar Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with round connector M12 IP65 Polyamide fixing fitting nut Measurement range: -250...0 mbar Overload pressure: 2 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2AD31-4HC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2AD31-4HC2
Reference: 7MF8010-2AD31-4HC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: in-line seal according DIN 11851 with screw necks: DN 25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...2,5 bar abs. overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 25 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measurement range: 0...2.5 bar abs. Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ML5632-8ED10-1FA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8ED10-1FA0
Reference: 7ML5632-8ED10-1FA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 3" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 500 mm (19.69") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/ FM Class II, III Div.1 Gr..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 3" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 500 mm (19.69") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Al
Delivery: See availability
7MF8010-2AF31-4DA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2AF31-4DA2
Reference: 7MF8010-2AF31-4DA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: in-line seal according DIN 11851 with screw necks: DN 40 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...10 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 40 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...10 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC47-1BD2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC47-1BD2
Reference: 7ME6820-2YC47-1BD2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder Interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol External battery with 1.5 m
Delivery: See availability
7ME6820-2YC47-1PA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC47-1PA1
Reference: 7ME6820-2YC47-1PA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7ME6820-2YC47-2LS0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC47-2LS0
Reference: 7ME6820-2YC47-2LS0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) Internal battery (battery not included)
Delivery: See availability
7ME6820-2YC47-2ND4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC47-2ND4
Reference: 7ME6820-2YC47-2ND4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus 115/230 V AC protocol for power
Delivery: See availability
7ME6820-2YC48-1LB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-1LB1
Reference: 7ME6820-2YC48-1LB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole RS 485 connectors as standard with MODBUS RTU (with line termination
Delivery: See availability
7ME6820-2YC48-2BT1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-2BT1
Reference: 7ME6820-2YC48-2BT1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) and analog c
Delivery: See availability
7ME6820-2YC48-2DT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC48-2DT0
Reference: 7ME6820-2YC48-2DT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) and anal
Delivery: See availability
7ME6340-5DC13-2JF2 SIEMENS SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN..

SIEMENS

Manufacturer Code: 7ME6340-5DC13-2JF2
Reference: 7ME6340-5DC13-2JF2
Catalog Number: -
SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN300, 12 Inch EN 1092-1, PN 16 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE max 150°C (302°F) Hastelloy C without grounding electrodes MAG 6000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 115-230V AC 50/60 Hz PROFIBUS PA Profil 3 1/2 inch NPT cable glands, Polyamid terminal box or MAG 6000i integral mount
SITRANS FM MAG 3100 Extremely precise electromagnetic flow sensor, with flange, diameter from DN 15 to DN 300 (from 1/2" to 12"). Suitable for continuous volumetric flow measurement of liquids (conductors), it is primarily used in the chemical industry, process industry, pulp and paper, water and wastewater. . Nominal diameter: DN 300 (12") Flange and nominal pressure standard: EN 1092-1: PN 16 (DN 65... 300 (2 1/2"… 12")) ASTM A 105 Carbon Steel Flanges, Category C4 Corrosion Resistant Coating Coating Material: PTFE max 150°C (302°F) Hastelloy C without grounding electrodes Transmitter with indicator: MAG 6000 I, (polyamide) 115 - 230 V AC Communication: PROFIBUS PA Profile 3 (MAG 6000/MAG 6000 I only) 1/2 in. cable gland NPT, polyamide terminal box or compact MAG 6000i
Delivery: See availability
7ME6820-2YJ00-2ND0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ00-2ND0
Reference: 7ME6820-2YJ00-2ND0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery not i
Delivery: See availability
7MF8010-1AH31-3EE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1AH31-3EE2
Reference: 7MF8010-1AH31-3EE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with slotted union nut: DN 65 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: -600...0 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Sanitary connection according to DIN 11851 with Fitting nut: DN 65 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with round connector M12 IP65 Stainless steel fixing fitting nut. Measuring range: -600...0 mbar Overload pressure: 6 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YJ02-2DD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ02-2DD0
Reference: 7ME6820-2YJ02-2DD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery no
Delivery: See availability
7MF8010-2CH31-5BD2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2CH31-5BD2
Reference: 7MF8010-2CH31-5BD2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according DIN 32676: DN 65 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...400 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Clamp connection according to DIN 32676: DN 65 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (internal ventilation for measuring ranges less than 10 bar measuring range: 0...400 mbar Overload pressure: 6 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2DM31-3HB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2DM31-3HB2
Reference: 7MF8010-2DM31-3HB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according ISO 2852 /DIN 32676: 1 Inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...1,6 bar abs. overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: c) tubular separator seal (threaded connection on both sides)/ quick releases: Clamp connection according to ISO 2852/ DIN 32676: 1 in. Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: 0...1.6 bar ABS. Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YJ03-2LD1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ03-2LD1
Reference: 7ME6820-2YJ03-2LD1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Encoder Interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Built-in internal battery
Delivery: See availability
7ME6820-2YJ04-1KD3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ04-1KD3
Reference: 7ME6820-2YJ04-1KD3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor Encoder Interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: ANSI B16.5: Class 150 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Q3/Q1 = 160 MI-001 verification Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Advanced version integrated in the sensor Transmitter interface module for ITRON 200WP Radio with Sensus Protocol 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cord for ex
Delivery: See availability
7MF8010-1BF31-3HB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1BF31-3HB2
Reference: 7MF8010-1BF31-3HB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: connection o.cc.according DIN 11851 with screw necks: DN 40 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...1,6 bar abs. overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ quick releases: Sanitary connection according to DIN 11851 with threaded nozzle: DN 40 Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with round connector M12 IP65 Stainless steel fixing fitting nut. Measuring range: 0...1.6 bar ABS. Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2DP31-5BD2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2DP31-5BD2
Reference: 7MF8010-2DP31-5BD2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection: clamp-connection according ISO 2852 /DIN 32676: 2 Inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...400 mbar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process connection type: c) tubular separator seal (threaded joint on both sides)/ quick releases: Clamp connection according to ISO 2852/ DIN 32676: 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with grommet, IP67(small) (indoor ventilation for measuring ranges less than 10 bar measuring range: 0...400 mbar Overload pressure: 6 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2QM31-3FB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2QM31-3FB2
Reference: 7MF8010-2QM31-3FB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: -1...0,6 bar overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. PNEUMO): 1 in. Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: -1...0.6 bar Overload pressure: 10 bar Explosion protection according to ATEX 1
Delivery: See availability
7ME6820-2YJ05-1LA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-1LA3
Reference: 7ME6820-2YJ05-1LA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type & Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24V Power AC/DC with battery backup and 3m
Delivery: See availability
7ME6820-2YJ05-2DD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2DD0
Reference: 7ME6820-2YJ05-2DD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery not in
Delivery: See availability
7ME6820-2YJ05-2MA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2MA3
Reference: 7ME6820-2YJ05-2MA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24V Power AC/DC with battery backup and 3m (9.8
Delivery: See availability
7MF8010-2QP31-2CA1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2QP31-2CA1
Reference: 7MF8010-2QP31-2CA1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: 0...1 bar overload pressure: 3 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. NEUMO): 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut measurement range: 0...1 bar Overload pressure: 10 bar No explosion protection
Delivery: See availability
7ME6820-2YJ06-2CC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ06-2CC1
Reference: 7ME6820-2YJ06-2CC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ06-2EB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ06-2EB3
Reference: 7ME6820-2YJ06-2EB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM & Hastelloy Electrode Coating, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pin RS 485 Connectors Standard with MODBUS RTU (with Termination of 12/24 V AC/DC power with battery backup and
Delivery: See availability
7ME6820-2YJ06-2LB1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ06-2LB1
Reference: 7ME6820-2YJ06-2LB1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of Built-in internal battery
Delivery: See availability
7ME6820-2YJ07-1CA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ07-1CA1
Reference: 7ME6820-2YJ07-1CA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ08-1LT3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ08-1LT3
Reference: 7ME6820-2YJ08-1LT3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: ANSI B16.5: Class 150 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Approval/verification: No verification according to OIML R 49 (Q3/Q1 = 250) Specific regional version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) an
Delivery: See availability
7MF8010-2VP31-2CD2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2VP31-2CD2
Reference: 7MF8010-2VP31-2CD2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, with screw necks W501: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: 0...4 bar overload pressure: 20 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, with W501 threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. NEUMO): 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut measurement range: 0...4 bar Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2
Delivery: See availability
7ME6820-2YJ42-2AC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ42-2AC1
Reference: 7ME6820-2YJ42-2AC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors RS 232 Serial Port with MODBUS RTU Built-in Internal Battery
Delivery: See availability

products sitemap