SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5652-5NB00-0HA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5NB00-0HA0
Reference: 7ML5652-5NB00-0HA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: Waterproof batten 4" ASME, 150 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: Waterproof batten 4" ASME, 150 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-5ND00-0KA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5ND00-0KA0
Reference: 7ML5652-5ND00-0KA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 150 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flang
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 150 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-5PD00-0CA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5PD00-0CA1
Reference: 7ML5652-5PD00-0CA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length:
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Exte
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 300 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5728-2GC31-5FF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2GC31-5FF0
Reference: 7ML5728-2GC31-5FF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5652-6AA00-0HA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6AA00-0HA0
Reference: 7ML5652-6AA00-0HA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 16 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5728-2CA21-2FD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2CA21-2FD0
Reference: 7ML5728-2CA21-2FD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Racket: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Racket: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-2CA21-4BB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2CA21-4BB0
Reference: 7ML5728-2CA21-4BB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-2CA21-5CE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2CA21-5CE0
Reference: 7ML5728-2CA21-5CE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-2JB21-2BF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2JB21-2BF0
Reference: 7ML5728-2JB21-2BF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Rectangular Shovel, 50 x 150 mm (1.97 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 48 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Rectangular Shovel, 50 x 150 mm (1.97 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-2CB31-2CB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2CB31-2CB0
Reference: 7ML5728-2CB31-2CB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Racket: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Racket: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-2CB31-3DE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2CB31-3DE0
Reference: 7ML5728-2CB31-3DE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-1JB31-2AF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1JB31-2AF0
Reference: 7ML5728-1JB31-2AF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Scoop Size: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-1JB31-3CC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1JB31-3CC0
Reference: 7ML5728-1JB31-3CC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Scoop Size: Rectangular Shovel, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Scoop Size: Rectangular Shovel, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-1LB31-5AC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1LB31-5AC0
Reference: 7ML5728-1LB31-5AC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Shovel: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Shovel: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3JB31-5CE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JB31-5CE0
Reference: 7ML5728-3JB31-5CE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5632-8AB00-1FB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AB00-1FB0
Reference: 7ML5632-8AB00-1FB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 250 mm (9.84") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 250 mm (9.84") Thermal insulation: Without thermal insulator Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65
Delivery: See availability
7ML5632-8AB10-1GD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AB10-1GD0
Reference: 7ML5632-8AB10-1GD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 250 mm (9.84") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 ca
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 250 mm (9.84") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G
Delivery: See availability
7ML5632-8AB20-1FC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AB20-1FC0
Reference: 7ML5632-8AB20-1FC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 250 mm (9.84") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 250 mm (9.84") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2"
Delivery: See availability
7ML5728-3CC21-5CD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3CC21-5CD0
Reference: 7ML5728-3CC21-5CD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3CC31-2CA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3CC31-2CA0
Reference: 7ML5728-3CC31-2CA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-2LC31-3EF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2LC31-3EF0
Reference: 7ML5728-2LC31-3EF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Shovel: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Shovel: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-2LC31-5EE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2LC31-5EE0
Reference: 7ML5728-2LC31-5EE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5632-8BH10-0EA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BH10-0EA0
Reference: 7ML5632-8BH10-0EA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet,
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1350 mm (53.15") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6 approval...
Delivery: See availability
7ML5632-8BJ01-0GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BJ01-0GC0
Reference: 7ML5632-8BJ01-0GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1500 mm (59.06") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via ad
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1500 mm (59.06") Thermal insulation: Without thermal insulation Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM
Delivery: See availability
7ML5632-8AE10-1FA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AE10-1FA0
Reference: 7ML5632-8AE10-1FA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 750 mm (29.53") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 750 mm (29.53") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid
Delivery: See availability
7ML5632-8AF00-0KA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AF00-0KA0
Reference: 7ML5632-8AF00-0KA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CE, C-TICK) with WHG approval Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5652-3AB00-0KC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-3AB00-0KC0
Reference: 7ML5652-3AB00-0KC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5632-8AF10-1KB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AF10-1KB0
Reference: 7ML5632-8AF10-1KB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) with WHG approval Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5652-3BD00-0DB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-3BD00-0DB1
Reference: 7ML5652-3BD00-0DB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shi
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5632-8AF20-0GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AF20-0GB0
Reference: 7ML5632-8AF20-0GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1000 mm (39.37") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 C
Delivery: See availability
7ML5652-3BD00-0FC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-3BD00-0FC0
Reference: 7ML5652-3BD00-0FC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Length: Standard
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Length: Standard Leng
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5632-8AG00-1ED0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG00-1ED0
Reference: 7ML5632-8AG00-1ED0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe Approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6 approval... T4, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated,
Delivery: See availability
7ML5652-3BD00-0KB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-3BD00-0KB0
Reference: 7ML5652-3BD00-0KB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 1" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-3DD00-0CB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-3DD00-0CB1
Reference: 7ML5652-3DD00-0CB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 1 1/2" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended screen - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 1 1/2" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended screen - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 1 1/2"(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5632-8AH00-0FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AH00-0FD0
Reference: 7ML5632-8AH00-0FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1350 mm (53.15") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68
Delivery: See availability
7ML5728-1CC21-2DF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1CC21-2DF0
Reference: 7ML5728-1CC21-2DF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Shovel: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Shovel: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-1EA21-4AE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1EA21-4AE0
Reference: 7ML5728-1EA21-4AE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5652-6HD00-0FB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6HD00-0FB1
Reference: 7ML5652-6HD00-0FB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 80, PN 40 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 80, PN 40 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shie
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 80, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5728-1GA21-5AB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1GA21-5AB0
Reference: 7ML5728-1GA21-5AB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop size: Rectangular shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop size: Rectangular shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5652-6JD00-0CC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6JD00-0CC0
Reference: 7ML5652-6JD00-0CC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 100, PN 16 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 100, PN 16 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: St
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 100, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5728-1GB21-2AA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1GB21-2AA0
Reference: 7ML5728-1GB21-2AA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-1GB21-3BE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1GB21-3BE0
Reference: 7ML5728-1GB21-3BE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-1AB21-4AF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1AB21-4AF0
Reference: 7ML5728-1AB21-4AF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Scoop Size: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Scoop Size: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-1GB21-4AB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1GB21-4AB0
Reference: 7ML5728-1GB21-4AB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Size Racket: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Size Racket: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-1AB31-5CC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1AB31-5CC0
Reference: 7ML5728-1AB31-5CC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Rectangular Shovel, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Rectangular Shovel, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-2GA21-5AB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2GA21-5AB0
Reference: 7ML5728-2GA21-5AB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop size: Rectangular shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop size: Rectangular shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-2AB31-3CA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2AB31-3CA0
Reference: 7ML5728-2AB31-3CA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-2GB31-5FD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2GB31-5FD0
Reference: 7ML5728-2GB31-5FD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-2GC21-5CA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2GC21-5CA0
Reference: 7ML5728-2GC21-5CA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-2AC21-5BE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2AC21-5BE0
Reference: 7ML5728-2AC21-5BE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-3GC21-5DE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GC21-5DE0
Reference: 7ML5728-3GC21-5DE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-3GC31-3AE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3GC31-3AE0
Reference: 7ML5728-3GC31-3AE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5632-8CE00-1GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CE00-1GC0
Reference: 7ML5632-8CE00-1GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 750 mm (29.53") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 750 mm (29.53") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epo
Delivery: See availability
7ML5632-8BB30-1FC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BB30-1FC0
Reference: 7ML5632-8BB30-1FC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 250 mm (9.84") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 250 mm (9.84") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy
Delivery: See availability
7ML5632-8BC10-0GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BC10-0GB0
Reference: 7ML5632-8BC10-0GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 350 mm (13.78") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, t
Delivery: See availability
7ML5632-8BC10-1EC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BC10-1EC0
Reference: 7ML5632-8BC10-1EC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 350 mm (13.78") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe Approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6 approval...
Delivery: See availability
7ML5632-8BC30-0FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BC30-0FD0
Reference: 7ML5632-8BC30-0FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 350 mm (13.78") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coat
Delivery: See availability
7ML5632-8BD01-0FA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BD01-0FA0
Reference: 7ML5632-8BD01-0FA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 500 mm (19.69") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 500 mm (19.69") Thermal insulator: Without thermal insulator Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy C
Delivery: See availability
7ML5632-8BD30-0FB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BD30-0FB0
Reference: 7ML5632-8BD30-0FB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 500 mm (19.69") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 500 mm (19.69") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy
Delivery: See availability
7ML5632-8BE30-1HA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BE30-1HA0
Reference: 7ML5632-8BE30-1HA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 750 mm (29.53") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 750 mm (29.53") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe Approvals: General Purpose (CSA, FM) Case & Lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5632-8BG00-1CC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BG00-1CC0
Reference: 7ML5632-8BG00-1CC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulation: Without thermal insulation Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68
Delivery: See availability
7ML5652-0BD00-0DA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0DA0
Reference: 7ML5652-0BD00-0DA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Shield Le
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Shield Length
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0BD00-0JB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0JB1
Reference: 7ML5652-0BD00-0JB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Delivery: See availability
7ML5652-0CB00-0DC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CB00-0DC0
Reference: 7ML5652-0CB00-0DC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Len
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CC00-0DA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0DA0
Reference: 7ML5652-0CC00-0DA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Shield
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Shield Len
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0DC00-0GC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DC00-0GC1
Reference: 7ML5652-0DC00-0GC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter -
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cab
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-1BA00-0DC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BA00-0DC0
Reference: 7ML5652-1BA00-0DC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Standard, 350 mm (13.78") rod Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Sh
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Standard, 350 mm (13.78") rod Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BD00-0HC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0HC1
Reference: 7ML5652-1BD00-0HC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-5PB00-0HD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5PB00-0HD0
Reference: 7ML5652-5PB00-0HD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 300 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-5QB00-0CD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5QB00-0CD1
Reference: 7ML5652-5QB00-0CD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended scree
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended screen -
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5728-1CA21-2DB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1CA21-2DB0
Reference: 7ML5728-1CA21-2DB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5652-5QB00-0JC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5QB00-0JC0
Reference: 7ML5652-5QB00-0JC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-5QD00-0HD2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5QD00-0HD2
Reference: 7ML5652-5QD00-0HD2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-6AD00-0CC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6AD00-0CC1
Reference: 7ML5652-6AD00-0CC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extend
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended s
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5728-1JC31-2CB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1JC31-2CB0
Reference: 7ML5728-1JC31-2CB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Racket: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Racket: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-1JC31-3DE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1JC31-3DE0
Reference: 7ML5728-1JC31-3DE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-2CB31-4CA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2CB31-4CA0
Reference: 7ML5728-2CB31-4CA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-2CB31-5DC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2CB31-5DC0
Reference: 7ML5728-2CB31-5DC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-1LB21-3DF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1LB21-3DF0
Reference: 7ML5728-1LB21-3DF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Scoop Size: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Scoop Size: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-2CC21-5EB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2CC21-5EB0
Reference: 7ML5728-2CC21-5EB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Racket: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Racket: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-1LB31-3AC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1LB31-3AC0
Reference: 7ML5728-1LB31-3AC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-2EA21-4DF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2EA21-4DF0
Reference: 7ML5728-2EA21-4DF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Shovel: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Shovel: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-1EB21-2CB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1EB21-2CB0
Reference: 7ML5728-1EB21-2CB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Racket: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Racket: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-1EB21-3DE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1EB21-3DE0
Reference: 7ML5728-1EB21-3DE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-2LB21-5DC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2LB21-5DC0
Reference: 7ML5728-2LB21-5DC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3EB21-3EB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB21-3EB0
Reference: 7ML5728-3EB21-3EB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-3EB21-4FE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB21-4FE0
Reference: 7ML5728-3EB21-4FE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-3EB31-5EC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3EB31-5EC0
Reference: 7ML5728-3EB31-5EC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 115 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5652-6DB00-0KA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6DB00-0KA1
Reference: 7ML5652-6DB00-0KA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 40 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 40 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 40, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-6EB00-0HA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6EB00-0HA0
Reference: 7ML5652-6EB00-0HA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 50, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-6EC00-0DD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6EC00-0DD0
Reference: 7ML5652-6EC00-0DD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 50, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-6EC00-0KC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6EC00-0KC1
Reference: 7ML5652-6EC00-0KC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm fla
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 50, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-6FD00-0CA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6FD00-0CA1
Reference: 7ML5652-6FD00-0CA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 40 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length:
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 40 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Ext
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 50, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5632-8AF10-0GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AF10-0GA0
Reference: 7ML5632-8AF10-0GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cab
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam.
Delivery: See availability
7ML5632-8AG00-0CA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG00-0CA0
Reference: 7ML5632-8AG00-0CA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5632-8AG01-0JB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG01-0JB0
Reference: 7ML5632-8AG01-0JB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulation: Without thermal insulation Seals on process side: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8AC10-0GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AC10-0GA0
Reference: 7ML5632-8AC10-0GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cabl
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 350 mm (13.78") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam.
Delivery: See availability
7ML5652-6AB00-0GA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6AB00-0GA0
Reference: 7ML5652-6AB00-0GA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Alum
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm
Delivery: See availability
7ML5632-8AG10-1CA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG10-1CA0
Reference: 7ML5632-8AG10-1CA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1250 mm (49.21") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x 1/2" NPT via adapter - Cable e
Delivery: See availability
7ML5632-8AC10-1KD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AC10-1KD0
Reference: 7ML5632-8AC10-1KD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) with WHG approval Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 350 mm (13.78") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability

products sitemap