SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5728-2NC31-3CA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2NC31-3CA0
Reference: 7ML5728-2NC31-3CA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 5 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 5 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-1EC21-2BE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1EC21-2BE0
Reference: 7ML5728-1EC21-2BE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 1 1/min connection to the process assembly flanged: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 1 1/min connection to the process assembly flanged: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-2NC31-5FA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2NC31-5FA0
Reference: 7ML5728-2NC31-5FA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 5 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 5 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-3AB31-2AC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AB31-2AC0
Reference: 7ML5728-3AB31-2AC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-3AB31-3BF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AB31-3BF0
Reference: 7ML5728-3AB31-3BF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-2GB21-5AB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2GB21-5AB0
Reference: 7ML5728-2GB21-5AB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop size: Rectangular shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop size: Rectangular shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-2GB31-2DB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2GB31-2DB0
Reference: 7ML5728-2GB31-2DB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-2GC31-2DE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2GC31-2DE0
Reference: 7ML5728-2GC31-2DE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5632-8AK01-0CA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AK01-0CA0
Reference: 7ML5632-8AK01-0CA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1750 mm (68.90") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1750 mm (68.90") Thermal insulation: Without thermal insulation Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5632-8AL20-1GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AL20-1GA0
Reference: 7ML5632-8AL20-1GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet,
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 2000 mm (78.74") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Cas
Delivery: See availability
7ML5632-8BA00-1JA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BA00-1JA0
Reference: 7ML5632-8BA00-1JA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Compact design 98 mm (3.86") Thermal insulator: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5728-3JA21-3DD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JA21-3DD0
Reference: 7ML5728-3JA21-3DD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3JA21-4FA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JA21-4FA0
Reference: 7ML5728-3JA21-4FA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CSA/FM Dust Resistant Explosive Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CSA/FM Dust Resistant Explosive Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-3JA21-5DC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3JA21-5DC0
Reference: 7ML5728-3JA21-5DC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 48 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5632-8CG10-0FC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CG10-0FC0
Reference: 7ML5632-8CG10-0FC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: With thermal insulator (for process connection temperatures above +85 °C (+185 F)) Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Ep
Delivery: See availability
7ML5632-8CG10-1KA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8CG10-1KA0
Reference: 7ML5632-8CG10-1KA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) with WHG approval Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NPT cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulator: With thermal insulator (for process connection temperatures above +85 °C (+185 F)) Process side seals: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Delivery: See availability
7ML5652-6JC00-0GA2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6JC00-0GA2
Reference: 7ML5652-6JC00-0GA2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 100, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & L
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 100, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid:
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 100, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm
Delivery: See availability
7ML5652-6KB00-0JC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6KB00-0JC1
Reference: 7ML5652-6KB00-0JC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 100, PN 40 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 100, PN 40 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 100, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5728-1AB21-2AA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1AB21-2AA0
Reference: 7ML5728-1AB21-2AA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-2AB31-4CC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2AB31-4CC0
Reference: 7ML5728-2AB31-4CC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Scoop Size: Rectangular Shovel, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Scoop Size: Rectangular Shovel, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5632-8BJ10-1DB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BJ10-1DB0
Reference: 7ML5632-8BJ10-1DB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1500 mm (59.06") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T 100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1500 mm (59.06") Thermal insulator: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure (explosion-proof) with intrinsically safe (IS) probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T
Delivery: See availability
7ML5652-5PA00-0JD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5PA00-0JD0
Reference: 7ML5652-5PA00-0JD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" Sealed Strip, 300 lb Special Version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" Sealed Strip, 300 lb Special Version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 300 lb Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-5PD00-0KA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5PD00-0KA0
Reference: 7ML5652-5PD00-0KA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flan
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 300 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-5QD00-0DC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5QD00-0DC2
Reference: 7ML5652-5QD00-0DC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2"
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 4" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 4" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flange
Delivery: See availability
7ML5652-6AB00-0FB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6AB00-0FB0
Reference: 7ML5652-6AB00-0FB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shield L
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shield Lengt
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-6AC00-0CC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6AC00-0CC1
Reference: 7ML5652-6AC00-0CC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length:
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Exte
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-6AC00-0GB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6AC00-0GB1
Reference: 7ML5652-6AC00-0GB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Li
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: A
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230
Delivery: See availability
7ML5728-1JB31-5EC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1JB31-5EC0
Reference: 7ML5728-1JB31-5EC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-1JC21-2DD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1JC21-2DD0
Reference: 7ML5728-1JC21-2DD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 80 C (176 F) Auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 80 C (176 F) Auxiliary power: AC 48 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-1LB31-4AF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1LB31-4AF0
Reference: 7ML5728-1LB31-4AF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Scoop Size: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Scoop Size: Rectangular Shovel, 50 x 98 mm (1.97 x 3.86 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-2LA21-3AB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2LA21-3AB0
Reference: 7ML5728-2LA21-3AB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Racket: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Racket: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-2LA21-3ED0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2LA21-3ED0
Reference: 7ML5728-2LA21-3ED0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5652-6BB00-0CD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6BB00-0CD1
Reference: 7ML5652-6BB00-0CD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 40 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended scr
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 40 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended screen
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-6BC00-0GD2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6BC00-0GD2
Reference: 7ML5652-6BC00-0GD2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 40 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Li
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 40 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: A
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380
Delivery: See availability
7ML5652-6BD00-0CC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6BD00-0CC2
Reference: 7ML5652-6BD00-0CC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 40 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length:
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 25, PN 40 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Ext
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 25, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-6CB00-0EA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6CB00-0EA0
Reference: 7ML5652-6CB00-0EA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coat
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 40, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm thr
Delivery: See availability
7ML5652-6CB00-0KC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6CB00-0KC1
Reference: 7ML5652-6CB00-0KC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 16 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 40, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-6CC00-0HD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6CC00-0HD0
Reference: 7ML5652-6CC00-0HD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 16 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 40, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-6DA00-0FA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6DA00-0FA0
Reference: 7ML5652-6DA00-0FA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 40 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Shi
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 40 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Shield
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 40, PN 40 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-6DB00-0FA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6DB00-0FA1
Reference: 7ML5652-6DB00-0FA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 40 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Ac
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 40, PN 40 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 40, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-6EA00-0HB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6EA00-0HB0
Reference: 7ML5652-6EA00-0HB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 50, PN 16 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-6ED00-0JC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6ED00-0JC0
Reference: 7ML5652-6ED00-0JC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 16 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 50, PN 16 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-6FC00-0DC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6FC00-0DC2
Reference: 7ML5652-6FC00-0DC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 40 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 50, PN 40 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NP
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 50, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flan
Delivery: See availability
7ML5728-1LC31-3AD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1LC31-3AD0
Reference: 7ML5728-1LC31-3AD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). Process temperature: Up to 80 C (176 F) auxiliary power: DC 24 V, 1 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 24 V DC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-2NA21-5AE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2NA21-5AE0
Reference: 7ML5728-2NA21-5AE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 5 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 5 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5632-8AH30-0FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AH30-0FD0
Reference: 7ML5632-8AH30-0FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: Remote mount electronics with 5 m (197") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1350 mm (53.15") Thermal insulator: Separate electronics with 5 m (197") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated,
Delivery: See availability
7ML5632-8AJ00-0CB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AJ00-0CB0
Reference: 7ML5632-8AJ00-0CB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1500 mm (59.06") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 1500 mm (59.06") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8AK00-1DC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AK00-1DC0
Reference: 7ML5632-8AK00-1DC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1750 mm (68.90") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Flameproof Enclosure With IS Probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T 100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1750 mm (68.90") Thermal insulation: Without thermal insulation Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure (explosion-proof) with intrinsically safe (IS) probe CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x
Delivery: See availability
7ML5652-6HD00-0JC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-6HD00-0JC1
Reference: 7ML5652-6HD00-0JC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 80, PN 40 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, flat flange type A: DN 80, PN 40 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 80, PN 40 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5728-2AA21-4BC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2AA21-4BC0
Reference: 7ML5728-2AA21-4BC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Scoop Size: Rectangular Shovel, 50 x 150 mm (1.97 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Scoop Size: Rectangular Shovel, 50 x 150 mm (1.97 x 5.91 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-2AB31-5DF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2AB31-5DF0
Reference: 7ML5728-2AB31-5DF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 230 V, 1 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Rectangular Shovel, 98 x 150 mm (3.86 x 5.91 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-3AA21-4DD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AA21-4DD0
Reference: 7ML5728-3AA21-4DD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Size Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-3AA21-5FA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AA21-5FA0
Reference: 7ML5728-3AA21-5FA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Measuring Shovel: Articulated Shovel, 65 x 210 mm (2.56 x 8.27 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Hinged vane, 65 x 210 mm (2.56 x 8.27 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-3AB21-3CA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AB21-3CA0
Reference: 7ML5728-3AB21-3CA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-3AC31-5CD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AC31-5CD0
Reference: 7ML5728-3AC31-5CD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Size Blade: Rectangular Blade, 50 x 250 mm (1.97 x 9.84 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5632-8BC01-0KB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BC01-0KB0
Reference: 7ML5632-8BC01-0KB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 350 mm (13.78") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CE, C-TICK) with WHG approval Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 350 mm (13.78") Thermal insulation: Without thermal insulation Seals on process side: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8BD10-1CB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BD10-1CB0
Reference: 7ML5632-8BD10-1CB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 500 mm (19.69") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 500 mm (19.69") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5652-5FD00-0DD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5FD00-0DD1
Reference: 7ML5652-5FD00-0DD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Sealed Strip, 600 lb Special Version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M2
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Sealed Strip, 600 lb Special Version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 1 1/2" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5632-8BE00-0GD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BE00-0GD0
Reference: 7ML5632-8BE00-0GD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 750 mm (29.53") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 750 mm (29.53") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum,
Delivery: See availability
7ML5652-5FD00-0HC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5FD00-0HC0
Reference: 7ML5652-5FD00-0HC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Sealed Strip, 600 lb Special Version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Sealed Strip, 600 lb Special Version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 1 1/2" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5632-8BF00-1JB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BF00-1JB0
Reference: 7ML5632-8BF00-1JB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5652-5GB00-0FB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5GB00-0FB1
Reference: 7ML5652-5GB00-0FB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" Sealed Slat, 150 lb Special Version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shield
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" Sealed Slat, 150 lb Special Version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shield Leng
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-5GC00-0ED2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5GC00-0ED2
Reference: 7ML5652-5GC00-0ED2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 150 lb Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, ep
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 150 lb Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm fla
Delivery: See availability
7ML5652-5GD00-0EC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5GD00-0EC0
Reference: 7ML5652-5GD00-0EC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 150 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum,
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 150 lb Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epox
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm thread
Delivery: See availability
7ML5652-5HB00-0EA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5HB00-0EA1
Reference: 7ML5652-5HB00-0EA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epo
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy c
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 2" ASME, 300 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm thread
Delivery: See availability
7ML5652-5HB00-0KD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5HB00-0KD0
Reference: 7ML5652-5HB00-0KD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 300 lb Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 2" ASME, 300 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-5JA00-0FA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5JA00-0FA0
Reference: 7ML5652-5JA00-0FA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 600 lb Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Activ
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 600 lb Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Sh
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 2" ASME, 600 lb Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-5JC00-0JB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5JC00-0JB1
Reference: 7ML5652-5JC00-0JB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" watertight slat, 600 lb Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 2" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-5KC00-0DA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-5KC00-0DA0
Reference: 7ML5652-5KC00-0DA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 3" watertight slat, 150 lb Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated,
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 3" watertight slat, 150 lb Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, raised face: 3" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flange
Delivery: See availability
7ML5728-1GB31-4EA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1GB31-4EA0
Reference: 7ML5728-1GB31-4EA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5728-1GC21-3BE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1GC21-3BE0
Reference: 7ML5728-1GC21-3BE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-1GC31-2EB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1GC31-2EB0
Reference: 7ML5728-1GC31-2EB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 115 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Measuring Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 115 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5728-2NC31-5EF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2NC31-5EF0
Reference: 7ML5728-2NC31-5EF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 5 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: DC 24 V, 5 1/min connection to process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 300 mm (11.81 inches) Scoop Size: Rectangular Shovel, 98 x 250 mm (3.86 x 9.84 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 24 V DC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 300 mm (11.81 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5632-8AF10-0EB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AF10-0EB0
Reference: 7ML5632-8AF10-0EB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Flameproof Enclosure With IS Probe With WHG Approval CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) probe, with WHG CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6 approval... T4,
Delivery: See availability
7ML5652-0DC00-0GA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DC00-0GA0
Reference: 7ML5652-0DC00-0GA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter -
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cab
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5728-3AB31-2AB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AB31-2AB0
Reference: 7ML5728-3AB31-2AB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5632-8AG01-0GC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG01-0GC0
Reference: 7ML5632-8AG01-0GC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapte
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1250 mm (49.21") Thermal insulation: Without thermal insulation Seals on process side: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM Class I probe, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM C
Delivery: See availability
7ML5652-1AD00-0KD2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AD00-0KD2
Reference: 7ML5652-1AD00-0KD2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5728-1JB31-4CF0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1JB31-4CF0
Reference: 7ML5728-1JB31-4CF0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Shovel: Rectangular Shovel, 50 x 250 mm (1.97 x 9.84 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 48 V, 1 1/min Process connection flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Shovel: Rectangular Shovel, 50 x 250 mm (1.97 x 9.84 inches) Approvals: EAC Ex ta/tb IIIC Da/Db
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 48 V AC, 1 rev/min Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch) Approval: EAC Ex ta/tb IIIC Da/Db .
Delivery: See availability
7ML5728-3AB31-3BE0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AB31-3BE0
Reference: 7ML5728-3AB31-3BE0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: IEC Ex ta/tb IIIC
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: IEC Ex ta/tb IIIC .
Delivery: See availability
7ML5728-2EB21-4AA0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2EB21-4AA0
Reference: 7ML5728-2EB21-4AA0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: CSA/FM Protected for Explosive Dust Atmosphere, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: CSA/FM Dust Ignition Proof, RCM .
Delivery: See availability
7ML5632-8AG10-0JB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8AG10-0JB0
Reference: 7ML5632-8AG10-0JB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1250 mm (49.21") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1250 mm (49.21") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5652-1BD00-0HA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0HA0
Reference: 7ML5652-1BD00-0HA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5728-3AB31-4DB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-3AB31-4DB0
Reference: 7ML5728-3AB31-4DB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 250 C (482 F) auxiliary power: AC 230 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 98 x 150 mm (3.86 x 5.91 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +250 C (+482 F) Power supply: 230 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 10 bar (145 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability
7ML5652-3AC00-0ED1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-3AC00-0ED1
Reference: 7ML5652-3AC00-0ED1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable e
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5632-8BF10-0CB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BF10-0CB0
Reference: 7ML5632-8BF10-0CB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8BH01-0HB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BH01-0HB0
Reference: 7ML5632-8BH01-0HB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1350 mm (53.15") Thermal insulation: Without thermal insulation Seals on process side: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65
Delivery: See availability
7ML5632-8BH10-1GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BH10-1GA0
Reference: 7ML5632-8BH10-1GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2X 1/2" NP
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" sanitary clamp Special version: (length measured from the process connection face): Rod extension, 1350 mm (53.15") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1,
Delivery: See availability
7ML5632-8BJ00-1GB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8BJ00-1GB0
Reference: 7ML5632-8BJ00-1GB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 1 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1500 mm (59.06") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D CSA/FM Class II, Div. 1, Gr. E, F, G CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L: 1 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1500 mm (59.06") Thermal insulation: Without thermal insulation Seals on process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy
Delivery: See availability
7ML5652-0DD00-0KB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DD00-0KB1
Reference: 7ML5652-0DD00-0KB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-1AB00-0CC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AB00-0CC0
Reference: 7ML5652-1AB00-0CC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 m
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm fl
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1AD00-0GB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AD00-0GB0
Reference: 7ML5652-1AD00-0GB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 C
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BB00-0KB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BB00-0KB0
Reference: 7ML5652-1BB00-0KB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BD00-0DB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0DB1
Reference: 7ML5652-1BD00-0DB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield leng
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-1DC00-0EB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1DC00-0EB1
Reference: 7ML5652-1DC00-0EB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable ent
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry,
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-3AB00-0DA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-3AB00-0DA1
Reference: 7ML5652-3AB00-0DA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 A
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5728-1CB21-4BD0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1CB21-4BD0
Reference: 7ML5728-1CB21-4BD0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 5 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 5 1/min Process connection to flanged assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 250 mm (9.84 inches) Measuring Blade: Rectangular Blade, 50 x 150 mm (1.97 x 5.91 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 250 mm (9.84 inch) Measuring vane: Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-1CC21-3EC0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-1CC21-3EC0
Reference: 7ML5728-1CC21-3EC0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 80 C (176 F) auxiliary power: AC 230 V, 5 1/min connection to the process flanged assembly: 4" ASME 150 lbs B16.5 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CSA/FM General Purpose, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +80 C (+176 F) Power supply: 230 V AC, 5 rev/min. Process connection Flanged: 4" ASME 150 lbs B16.5 raised faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CSA/FM General Purpose, RCM .
Delivery: See availability
7ML5728-2EA21-3ED0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2EA21-3ED0
Reference: 7ML5728-2EA21-3ED0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 1 1/min connection to the process flanged assembly: DN100 PN6, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Material connection to the process: Stainless steel, no. mat. 1.4305, 1.4541 (303/321) Extension: 200 mm (7.87 inches) Size Blade: Rectangular Blade, 98 x 250 mm (3.86 x 9.84 inches) Approvals: CE, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 6, EN1092-1, flat faced (1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 200 mm (7.87 inch) Measuring vane: Rectangular vane 98 x 250 mm (3.86 x 9.84 inch) Approvals: CE, RCM .
Delivery: See availability
7ML5728-2EB21-2AB0 SIEMENS SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detecti..

SIEMENS

Manufacturer Code: 7ML5728-2EB21-2AB0
Reference: 7ML5728-2EB21-2AB0
Catalog Number: -
SITRANS LPS200 Switch. Rotary vane level, angular extension design: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
. SITRANS LPS200 Rotary vane level switch, design with angular extension: level detection in aggressive applications. Bottom or side mounting, variant with axle with protection. Optional extensions up to 300 mm (11.81 inch). process temperature: Up to 150 C (302 F) auxiliary power: AC 115 V, 1 1/min Process connection to flange assembly DN100 PN16, EN1092-1 (1.4541/321) process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel, mat no. 1.4305, 1.4541 (303/321) Extension: 150 mm (5.91 inches) Size Blade: Rectangular Blade, 50 x 98 mm (1.97 x 3.86 inches) Approvals: ATEX II 1/2 D, C-TICK
SITRANS LPS200 Rotary paddle point level switch, angled extension design: level detection in aggressive applications. Bottom or side mount with enhanced shaft protection. Extension options to 300 mm (11.81 inch). Process temperature: Up to +150 C (+302 F) Power supply: 115 V AC, 1 rev/min. Process connection Flanged: DN100 PN 16, EN1092-1 flat faced(1.4541/321) Process pressure: Up to 5 bar (72.5 psi) Process connection material: Stainless steel 303/321 (1.4305/1.4541) Extension length: 150 mm (5.91 inch) Measuring vane: Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Approvals: ATEX II 1/2 D, RCM .
Delivery: See availability

products sitemap