SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5652-0BC00-0HB2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BC00-0HB2
Reference: 7ML5652-0BC00-0HB2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Enlarged display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Enlarged display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CC00-0DC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0DC1
Reference: 7ML5652-0CC00-0DC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Len
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0DC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0DC2
Reference: 7ML5652-0CC00-0DC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield l
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield lengt
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CC00-0DD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0DD0
Reference: 7ML5652-0CC00-0DD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Stan
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Standard
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CC00-0DD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0DD1
Reference: 7ML5652-0CC00-0DD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Enlar
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Enlarged
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0DD2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0DD2
Reference: 7ML5652-0CC00-0DD2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Exten
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0BD00-0EC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0EC2
Reference: 7ML5652-0BD00-0EC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP6
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Ac
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0BC00-0HC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BC00-0HC0
Reference: 7ML5652-0BC00-0HC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CC00-0EA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0EA0
Reference: 7ML5652-0CC00-0EA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0BD00-0ED0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0ED0
Reference: 7ML5652-0BD00-0ED0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Sh
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0BD00-0ED1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0ED1
Reference: 7ML5652-0BD00-0ED1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shi
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CA00-0CA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CA00-0CA0
Reference: 7ML5652-0CA00-0CA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CA00-0CB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CA00-0CB0
Reference: 7ML5652-0CA00-0CB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CA00-0CC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CA00-0CC0
Reference: 7ML5652-0CA00-0CC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CB00-0GB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CB00-0GB0
Reference: 7ML5652-0CB00-0GB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry,
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP6
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1AD00-0EC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AD00-0EC0
Reference: 7ML5652-1AD00-0EC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapte
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter -
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1AD00-0EC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AD00-0EC1
Reference: 7ML5652-1AD00-0EC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapte
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter -
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-1AD00-0EC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AD00-0EC2
Reference: 7ML5652-1AD00-0EC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Ca
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-1AD00-0ED0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AD00-0ED0
Reference: 7ML5652-1AD00-0ED0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Ent
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry,
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1AD00-0ED1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AD00-0ED1
Reference: 7ML5652-1AD00-0ED1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entr
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, I
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CB00-0GA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CB00-0GA0
Reference: 7ML5652-0CB00-0GA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter -
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cab
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CB00-0GA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CB00-0GA1
Reference: 7ML5652-0CB00-0GA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter -
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cab
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0EB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0EB0
Reference: 7ML5652-0CC00-0EB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shi
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CC00-0KA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0KA0
Reference: 7ML5652-0CC00-0KA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CC00-0EA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0EA1
Reference: 7ML5652-0CC00-0EA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry,
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0EA2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0EA2
Reference: 7ML5652-0CC00-0EA2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry,
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CD00-0DD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0DD0
Reference: 7ML5652-0CD00-0DD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length:
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Stan
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CD00-0DD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0DD1
Reference: 7ML5652-0CD00-0DD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: E
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Enlar
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CD00-0DD2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0DD2
Reference: 7ML5652-0CD00-0DD2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: E
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Exten
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EA0
Reference: 7ML5652-0CD00-0EA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable E
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EA1
Reference: 7ML5652-0CD00-0EA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable ent
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry,
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0FC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0FC2
Reference: 7ML5652-0CC00-0FC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Length: Extended Display - (400 mm
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Length: Extended Display - (400 mm thr
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CD00-0KB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0KB1
Reference: 7ML5652-0CD00-0KB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0DB00-0CC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DB00-0CC1
Reference: 7ML5652-0DB00-0CC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended screen - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended screen - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0DB00-0JB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DB00-0JB0
Reference: 7ML5652-0DB00-0JB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1AC00-0DA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AC00-0DA0
Reference: 7ML5652-1AC00-0DA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Act
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1AC00-0JD2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AC00-0JD2
Reference: 7ML5652-1AC00-0JD2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0DC00-0EC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DC00-0EC0
Reference: 7ML5652-0DC00-0EC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BC00-0DD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BC00-0DD1
Reference: 7ML5652-1BC00-0DD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield l
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield lengt
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0HC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0HC0
Reference: 7ML5652-0CC00-0HC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EA2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EA2
Reference: 7ML5652-0CD00-0EA2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable ent
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry,
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-1BD00-0HD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0HD1
Reference: 7ML5652-1BD00-0HD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0HC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0HC1
Reference: 7ML5652-0CC00-0HC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EB0
Reference: 7ML5652-0CD00-0EB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Ac
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BD00-0HD2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0HD2
Reference: 7ML5652-1BD00-0HD2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CC00-0HC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0HC2
Reference: 7ML5652-0CC00-0HC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EB1
Reference: 7ML5652-0CD00-0EB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Act
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-1BD00-0JA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0JA0
Reference: 7ML5652-1BD00-0JA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CC00-0HD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0HD0
Reference: 7ML5652-0CC00-0HD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EB2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EB2
Reference: 7ML5652-0CD00-0EB2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminium, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 A
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminium, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Activ
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-1BD00-0JA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0JA1
Reference: 7ML5652-1BD00-0JA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0HD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0HD1
Reference: 7ML5652-0CC00-0HD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EC0
Reference: 7ML5652-0CD00-0EC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable E
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0BC00-0JD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BC00-0JD0
Reference: 7ML5652-0BC00-0JD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BD00-0JA2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0JA2
Reference: 7ML5652-1BD00-0JA2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CC00-0HD2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0HD2
Reference: 7ML5652-0CC00-0HD2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0BC00-0KA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BC00-0KA0
Reference: 7ML5652-0BC00-0KA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0BC00-0KA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BC00-0KA1
Reference: 7ML5652-0BC00-0KA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0BD00-0GB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0GB1
Reference: 7ML5652-0BD00-0GB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 A
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0BD00-0GB2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0GB2
Reference: 7ML5652-0BD00-0GB2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 A
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CA00-0HA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CA00-0HA0
Reference: 7ML5652-0CA00-0HA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CA00-0HB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CA00-0HB0
Reference: 7ML5652-0CA00-0HB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CB00-0JC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CB00-0JC0
Reference: 7ML5652-0CB00-0JC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CB00-0JC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CB00-0JC1
Reference: 7ML5652-0CB00-0JC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0FD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0FD0
Reference: 7ML5652-0CC00-0FD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Standard Length - (125 mm thread, 105 m
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Standard Length - (125 mm thread, 105 mm fl
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CC00-0FD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0FD1
Reference: 7ML5652-0CC00-0FD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Extended Display - (250 mm Thread, 230
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators approvals: Ex protection for dust with intrinsically safe (IS) probe: CSA/FM Class II, Div.1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Extended Display - (250 mm Thread, 230 mm F
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CSA/FM Class II, Div.1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CD00-0KB2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0KB2
Reference: 7ML5652-0CD00-0KB2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0DB00-0CD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DB00-0CD0
Reference: 7ML5652-0DB00-0CD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0DB00-0JB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DB00-0JB1
Reference: 7ML5652-0DB00-0JB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0DC00-0EC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DC00-0EC1
Reference: 7ML5652-0DC00-0EC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EC1
Reference: 7ML5652-0CD00-0EC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable E
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0BC00-0JD1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BC00-0JD1
Reference: 7ML5652-0BC00-0JD1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-1AC00-0GD0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AC00-0GD0
Reference: 7ML5652-1AC00-0GD0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Ca
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BD00-0JB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0JB0
Reference: 7ML5652-1BD00-0JB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0DC00-0EC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DC00-0EC2
Reference: 7ML5652-0DC00-0EC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry,
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CC00-0JA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0JA0
Reference: 7ML5652-0CC00-0JA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CD00-0EC2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0EC2
Reference: 7ML5652-0CD00-0EC2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable ent
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry,
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0BD00-0GA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0GA1
Reference: 7ML5652-0BD00-0GA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Ca
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-1BD00-0JB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0JB1
Reference: 7ML5652-1BD00-0JB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0DC00-0JB1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DC00-0JB1
Reference: 7ML5652-0DC00-0JB1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0JA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0JA1
Reference: 7ML5652-0CC00-0JA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CD00-0ED0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0ED0
Reference: 7ML5652-0CD00-0ED0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Ac
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0BD00-0GA2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0BD00-0GA2
Reference: 7ML5652-0BD00-0GA2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Ca
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-1BD00-0JB2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0JB2
Reference: 7ML5652-1BD00-0JB2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0DC00-0JB2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DC00-0JB2
Reference: 7ML5652-0DC00-0JB2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CC00-0JA2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0JA2
Reference: 7ML5652-0CC00-0JA2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CD00-0ED1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0ED1
Reference: 7ML5652-0CD00-0ED1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Act
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CA00-0GB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CA00-0GB0
Reference: 7ML5652-0CA00-0GB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Ac
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BD00-0JC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0JC0
Reference: 7ML5652-1BD00-0JC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1AC00-0DA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AC00-0DA1
Reference: 7ML5652-1AC00-0DA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 A
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Activ
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CC00-0JB0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CC00-0JB0
Reference: 7ML5652-0CC00-0JB0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0CD00-0ED2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0ED2
Reference: 7ML5652-0CD00-0ED2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Act
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-0CA00-0GC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CA00-0GC0
Reference: 7ML5652-0CA00-0GC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable E
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Standard, 350 mm (13.78") rod Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) probe: CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B,C,D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1BD00-0JC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BD00-0JC1
Reference: 7ML5652-1BD00-0JC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-0CD00-0KC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0CD00-0KC0
Reference: 7ML5652-0CD00-0KC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 1000 mm (39.37") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-0DB00-0JC0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-0DB00-0JC0
Reference: 7ML5652-0DB00-0JC0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: 1 1/2" NPT (tapered), ANSI/ASME B1.20.1 Special version: (length from flange face) Rod extension, length 500 mm (19.69") Seals on process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose, CE, C-TICK Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1AC00-0DA2 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AC00-0DA2
Reference: 7ML5652-1AC00-0DA2
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 A
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Activ
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5652-1AC00-0KA1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1AC00-0KA1
Reference: 7ML5652-1AC00-0KA1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 3/4" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose with WHG Approval (CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5652-1BC00-0EA0 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1BC00-0EA0
Reference: 7ML5652-1BC00-0EA0
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter -
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) probe, with WHG APPROVAL: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6... T1, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cab
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe With WHG Approval: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T1, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shiled Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5652-1DC00-0CC1 SIEMENS Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level ..

SIEMENS

Manufacturer Code: 7ML5652-1DC00-0CC1
Reference: 7ML5652-1DC00-0CC1
Catalog Number: -
Pointek CLS300 RF Switch. capacitive level, variant for high temperatures. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended screen - (250 mm thread, 230
. Pointek CLS300 RF Capacitive Level Switch, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Special version: (length from flange face) Rod extension, length 750 mm (29.53") Seals on the process side: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust with intrinsically safe (IS) probe: CE, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended screen - (250 mm thread, 230 mm
Pointek CLS300 RF Capacitance point level switch, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof with IS Probe: CE, C-TICK, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shiled Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability

products sitemap