SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

6DR5112-0EP01-0BA1 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5112-0EP01-0BA1
Reference: 6DR5112-0EP01-0BA1
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA with HART-interface; single action; Enclosure Stainless steel without inspection window (not Ex d) . Type of explosion protection: Intrinsic Safety Connection thread el.: 1/2" NPT / pneu.: G1/4 without limit monitor Analog Output Module (AOM), optionally available with device plug M12 (D coding) (Order code: -Z D53) . Brief instructions French / Spanish / Italian . with mounted pressure gauge made of plastic, IP31, aluminum block, G1/4 aluminum block, G1/4
SIPART PS2 Intelligent electro-pneumatic position regulator, 4...20mA, HART, Ex/nEx, single effect, stainless steel box, without window, for linear pneumatic actuators and fraction of turn. Non-contact position detection (NCS) (wear-free). Not related to P01/P02 pressure sensor option. Standard Protection Mode (Ex): Intrinsic Safety (Ex i). SITRANS I200 Output Isolator, can be ordered separately (7NG4131-1AA00). Cable entry: 1/2" NPT thread. Pneumatic connection: G1/4" thread. No limit monitor. Analog Output Module (AOM), Analog Position Feedback 4 ... 20 mA. Order option with fixed connector M12 -Z D53. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions Spanish / French / Italian. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). G1/4 aluminium gauge block, single acting with IP31 plastic pressure gauge (MPa, bar)
Delivery: See availability
7ML5433-1EC20-1AK0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-1EC20-1AK0
Reference: 7ML5433-1EC20-1AK0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Class 1 Process Connection Types: (all types have TFM1600 PTFE lens): 316L st/st (1.4435 or 1.4404) & 304L st/st (1.4301) DN100 Hygienic nozzle/ slotted nut (instrument side) to DIN 11851 Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets): Aluminum, 2 X M20 x 1.5 A: Approvals: Non Sparklng, NEPSI Ex nA IIC T4 Gc Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL Class I Types of connection to the process (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404) and stainless steel. 304L (1.4301): Aseptic/hygienic connection/ DN100 slotted nut (instrument side) according to DIN 11851 Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 A: Approvals: Non-sparking: NEPSI Ex nA IIC T4 Gc Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
6DR5112-0EM31-0BA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5112-0EM31-0BA0
Reference: 6DR5112-0EM31-0BA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA with HART-interface; single action; Enclosure Stainless steel without inspection window (not Ex d) . Type of explosion protection: Intrinsic Safety Connection thread el.: M20x1.5 / pneu.: 1/4" NPT Mechanic Limit Switches (MLS) Qptionally available with device plug M12 (D coding) Order code: -Z D57 Analog Output Module (AOM), optionally available with device plug M12 (D coding) (Order code: -Z D53) . Brief instructions French / Spanish / Italian . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position regulator, 4...20mA, HART, Ex/nEx, single effect, stainless steel box, without window, for linear pneumatic actuators and fraction of turn. Non-contact position detection (NCS) (wear-free). Not related to P01/P02 pressure sensor option. Standard Protection Mode (Ex): Intrinsic Safety (Ex i). SITRANS I200 Output Isolator, can be ordered separately (7NG4131-1AA00). "Cable entry: M20 x 1.5 thread. Pneumatic connection: 1/4" NPT thread." Mechanic Limit Switches (MLS), 2 mechanical limit value switches and 1 digital output. Not suitable for operation with "natural" gas. Analog Output Module (AOM), Analog Position Feedback 4 ... 20 mA. Order option with fixed connector M12 -Z D53. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions Spanish / French / Italian. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Pressure Gauge Block / Booster.
Delivery: See availability
7ML5662-0BC00-0BA2 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-0BC00-0BA2
Reference: 7ML5662-0BC00-0BA2
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") .
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminium, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-0CB00-0FC1 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-0CB00-0FC1
Reference: 7ML5662-0CB00-0FC1
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Length: Extended Display - (250 mm Thread, 230 mm Flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-5AC00-0DC2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5AC00-0DC2
Reference: 7ML5662-5AC00-0DC2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1...
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-5AC00-0DD2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5AC00-0DD2
Reference: 7ML5662-5AC00-0DD2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1...
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case & Lid: Aluminium, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Enlarged Display - (400 mm Thread, 380 mm Flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-5AD00-0BC0 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5AD00-0BC0
Reference: 7ML5662-5AD00-0BC0
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-tick, Atex II 1/2 D, 2 D IP6X T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-5AD00-0BC1 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-5AD00-0BC1
Reference: 7ML5662-5AD00-0BC1
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: Welded flange, 316L stainless steel, raised face: 1" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") .
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminium, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-0CC00-0DC1 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-0CC00-0DC1
Reference: 7ML5662-0CC00-0DC1
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side joints: Graphite Probe material: stainless steel, mat no. 1...
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1 1/4" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-5AD00-0HA2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5AD00-0HA2
Reference: 7ML5662-5AD00-0HA2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-5DB00-0BA0 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5DB00-0BA0
Reference: 7ML5662-5DB00-0BA0
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 500 mm (19.69") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 500 mm (19.69") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1 1/2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-5DB00-0BA1 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5DB00-0BA1
Reference: 7ML5662-5DB00-0BA1
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 500 mm (19.69") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 500 mm (19.69") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1 1/2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-5DB00-0JC0 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5DB00-0JC0
Reference: 7ML5662-5DB00-0JC0
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 500 mm (19.69") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 500 mm (19.69") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1 1/2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM, CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-5DB00-0JC1 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5DB00-0JC1
Reference: 7ML5662-5DB00-0JC1
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 500 mm (19.69") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 500 mm (19.69") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1 1/2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM, CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-5DC00-0BA0 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5DC00-0BA0
Reference: 7ML5662-5DC00-0BA0
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process Side Seals: Graphite Probe Material: Stainless Steel, Mat No. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 1 1/2" Sealed Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process Side Seals: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1 1/2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-1DC00-0FD2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-1DC00-0FD2
Reference: 7ML5662-1DC00-0FD2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. 1, tam.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Extended Display - (400 mm Thread, 380 mm Flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-1DC00-0GA0 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-1DC00-0GA0
Reference: 7ML5662-1DC00-0GA0
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Shield Length: Standard Length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-1DC00-0GA1 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-1DC00-0GA1
Reference: 7ML5662-1DC00-0GA1
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/ FM Class I, II, III Div. 1 Gr.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Class III T4 Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-1DC00-0GA2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-1DC00-0GA2
Reference: 7ML5662-1DC00-0GA2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Class III T4 Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-1BC00-0JC2 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-1BC00-0JC2
Reference: 7ML5662-1BC00-0JC2
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") .
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Extended display - (400 mm thread, 380 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: R 1" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM, CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-5MC00-0FD2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5MC00-0FD2
Reference: 7ML5662-5MC00-0FD2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 3" Waterproof Slat, 600 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 3" Waterproof Slat, 600 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Extended Display - (400 mm Thread, 380 mm Flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 3" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-5GC00-0JA2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5GC00-0JA2
Reference: 7ML5662-5GC00-0JA2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Enlarged display - (400 mm thread, 380 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM, CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-5LD00-0FC2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5LD00-0FC2
Reference: 7ML5662-5LD00-0FC2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 3" Sealed Slat, 300 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 3" Sealed Slat, 300 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Length: Extended Display - (400 mm thread, 380 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 3" ASME, 300 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-1DC00-0GB0 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-1DC00-0GB0
Reference: 7ML5662-1DC00-0GB0
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shield Length: Standard Length - (125mm Thread, 105mm Flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-5GC00-0JB1 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5GC00-0JB1
Reference: 7ML5662-5GC00-0JB1
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 2" Waterproof Slat, 150 lb Probe Length: (length from flange face) Rod extension, length 750 mm (29.53") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Extended display - (250 mm thread, 230 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM, CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-5LD00-0FD2 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-5LD00-0FD2
Reference: 7ML5662-5LD00-0FD2
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 3" Sealed Slat, 300 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: Welded flange, Stainless steel, mat no. 1.4404/316L, with: ASME 3" Sealed Slat, 300 lb Probe Length: (length from flange face) Rod extension, length 1000 mm (39.37") Process Side Joints: Graphite Probe Material: Stainless Steel, Mat No. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Extended Display - (400 mm Thread, 380 mm Flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 3" ASME, 300 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged)
Delivery: See availability
7ML5662-1DD00-0CD0 SIEMENS . Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. L..

SIEMENS

Manufacturer Code: 7ML5662-1DD00-0CD0
Reference: 7ML5662-1DD00-0CD0
Catalog Number: -
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6...
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe length: (length from flange face) Rod extension, length 1000 mm (39.37") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminium, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Standard Length - (125 mm Thread, 105 mm Flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4, ATEX II 1/2 D I IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability

products sitemap