SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5432-0FD20-0AD0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5432-0FD20-0AD0
Reference: 7ML5432-0FD20-0AD0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries in the chemical industry. Process Connection Material:Stainless steel 1.4404/1.4435 Flanged Process Connection Types (Stainless steel 1.4404/1.4435): 50A 10K JIS B 2220 raised face Communication: 4...20mA HART,start-up at <3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2" NPT Antenna Lens Material: TFM 1600 Flush lens Approvals: Non-incendive: CSA/FM Class I, Div. 2, Groups A, B, C, D T5, FCC, Industry Canada Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids and slurries in chemical industry applications. Material, process connection: Stainless steel 1.4404/1.4435 Types of flanged process connection (stainless steel 1.4404/1.4435): 50A 10K JIS B 2220 with highlight Communications: 4...20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2" NPT Lens material (antenna): TFM 1600 recessed lens Approvals: Non-incendiary: CSA/FM Class I, Div. 2, Groups A,B, C, D T5, FCC, Industry Canada Pressure: See pressure/temperature reduction curves in the service instructions
Delivery: See availability
6DR5112-0EM30-0BA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5112-0EM30-0BA0
Reference: 6DR5112-0EM30-0BA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA with HART-interface; single action; Enclosure Stainless steel without inspection window (not Ex d) . Type of explosion protection: Intrinsic Safety Connection thread el.: M20x1.5 / pneu.: 1/4" NPT Mechanic Limit Switches (MLS) Qptionally available with device plug M12 (D coding) Order code: -Z D57 without option module . Brief instructions French / Spanish / Italian . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position regulator, 4...20mA, HART, Ex/nEx, single effect, stainless steel box, without window, for linear pneumatic actuators and fraction of turn. Non-contact position detection (NCS) (wear-free). Not related to P01/P02 pressure sensor option. Standard Protection Mode (Ex): Intrinsic Safety (Ex i). SITRANS I200 Output Isolator, can be ordered separately (7NG4131-1AA00). "Cable entry: M20 x 1.5 thread. Pneumatic connection: 1/4" NPT thread." Mechanic Limit Switches (MLS), 2 mechanical limit value switches and 1 digital output. Not suitable for operation with "natural" gas. No option module. . Short instructions Spanish / French / Italian. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Pressure Gauge Block / Booster.
Delivery: See availability
7ML5433-1DC20-0AE0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-1DC20-0AE0
Reference: 7ML5433-1DC20-0AE0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Class 1 Process Connection Types: (all types have TFM1600 PTFE lens)316L: st/st (1.4435 or 1.4404): DN100 Aseptic/Hygienic clamp according to DIN 11864/11853-3(Form A) Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Non Sparking, ATEX II 3G Ex nA IIC T4 Gc, CE, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL Class I Types of connection to the process (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Aseptic/hygienic clamp DN100 connection according to DIN 11864-3 (Form A) Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Increased Safety / Non Sparking: ATEX II 3G Ex ec IIC T4 Gc; UKEX II 3G Ex ec IIC T4 Gc; EAC Ex 2Ex nA IIC T4 Gc X; CE, UKCA, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5432-0FD20-0AF0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5432-0FD20-0AF0
Reference: 7ML5432-0FD20-0AF0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries in the chemical industry. Process Connection Material:Stainless steel 1.4404/1.4435 Flanged Process Connection Types (Stainless steel 1.4404/1.4435): 50A 10K JIS B 2220 raised face Communication: 4...20mA HART,start-up at <3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2" NPT Antenna Lens Material: TFM 1600 Flush lens Approvals: Increased Safety: IECEx/ATEX II 1/2 GD,1D, 2D Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex e ia mb IIC T4 Ga/Gb, Ex ia ta IIIC T100 C Da, CE, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids and slurries in chemical industry applications. Material, process connection: Stainless steel 1.4404/1.4435 Types of flanged process connection (stainless steel 1.4404/1.4435): 50A 10K JIS B 2220 with highlight Communications: 4...20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2" NPT Lens material (antenna): TFM 1600 recessed lens Approvals: Enhanced safety: ATEX II 1/2 GD, 1D, 2D, Ex eb mb ia IIC T4 Ga/Gb; UKEX II 1/2 GD, 1D, 2D, Ex eb mb ia IIC T4 Ga/Gb; IECEx Ex eb ia mb IIC T4 Ga/Gb; INMETRO Ex e ia mb IIC T4 Ga/Gb, INMETRO Ex ia ta IIIC T100°C Da, IP67/IP68; EAC Ex Ga/Gb Ex ia/e+mb IIC T4 X; CE, UKCA, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5033-2BA13-2B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BA13-2B
Reference: 7ML5033-2BA13-2B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Smartlinx Devicenet module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 100 ... 230 V AC Number of Measurement Points : Two-Point Version Data Communication (SmartLinx): SmartLinx DeviceNet Module Output Relays: 6 Relays (4 A Contacts, 2 C Contacts), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability
7ML5433-1YY20-0AD0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-1YY20-0AD0
Reference: 7ML5433-1YY20-0AD0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Class 1 Process Connection Types: 316L st/st (1.4435 or 1.4404) (all types have TFM1600 PTFE lens) EXCLUDE Process Connection - Electronics Head assembly spare only Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Non-incendive:CSA/FM Class I, Div. 2, Groups A,B,C,D T5, FCC, Industry Canada Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL Class I Types of connection to the process (all types have TFM1600 PTFE lens): WITHOUT connection to the process - Only spare head (electronic) assembly Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Non-incendive: CSA/FM, Class I, Div. 2, Groups A,B,C,D T5, FCC, Industry Canada Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5433-2FB20-0AD0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2FB20-0AD0
Reference: 7ML5433-2FB20-0AD0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: 316L st/st (1.4435 or 1.4404) (all types have TFM1600 PTFE lens) Type N (68 mm) Tuchenhagen Varivent EHEDG only Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Non-incendive:CSA/FM Class I, Div. 2, Groups A,B,C,D T5, FCC, Industry Canada Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Type N (68 mm) Tuchenhagen Varivent EHEDG only Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Non-incendive: CSA/FM,Class I, Div. 2, Groups A,B,C,D T5, FCC, Industry Canada Pressure: See pressure/temperature reduction curves in the service instructions
Delivery: See availability