SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5440-1CA00-1AB1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1CA00-1AB1
Reference: 7ML5440-1CA00-1AB1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5033-2BB03-2B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BB03-2B
Reference: 7ML5033-2BB03-2B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 12 to 30 VDC Number of measurement points: Single point version Data Communications (Smartlinx): Smartlinx Devicenet module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 12 ... 30 V DC Number of Measurement Points : Single Point Version Data Communication (SmartLinx): SmartLinx DeviceNet Module Output Relays: 6 Relays (4 A Contacts, 2 C Contacts), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability
7ML5433-2CC20-0AE0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2CC20-0AE0
Reference: 7ML5433-2CC20-0AE0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens)316L: st/st (1.4435 or 1.4404) DN100 Aseptic/Hygienic flanged to DIN 11864-2 (Form A) Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Non Sparking, ATEX II 3G Ex nA IIC T4 Gc, CE, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Aseptic/hygienic flanged connection DN100 according to DIN 11864-2 Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Increased Safety / Non Sparking: ATEX II 3G Ex ec IIC T4 Gc; UKEX II 3G Ex ec IIC T4 Gc; EAC Ex 2Ex nA IIC T4 Gc X; CE, UKCA, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
6DR5112-0EG30-0BA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5112-0EG30-0BA0
Reference: 6DR5112-0EG30-0BA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA with HART-interface; single action; Enclosure Stainless steel without inspection window (not Ex d) . Type of explosion protection: Intrinsic Safety Connection thread el.: M20x1.5 / pneu.: G 1/4 Mechanic Limit Switches (MLS) Qptionally available with device plug M12 (D coding) Order code: -Z D57 without option module . Brief instructions French / Spanish / Italian . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position regulator, 4...20mA, HART, Ex/nEx, single effect, stainless steel box, without window, for linear pneumatic actuators and fraction of turn. Non-contact position detection (NCS) (wear-free). Not related to P01/P02 pressure sensor option. Standard Protection Mode (Ex): Intrinsic Safety (Ex i). SITRANS I200 Output Isolator, can be ordered separately (7NG4131-1AA00). Cable entry: M20 x 1.5 thread. Pneumatic connection: G1/4 thread. Mechanic Limit Switches (MLS), 2 mechanical limit value switches and 1 digital output. Not suitable for operation with "natural" gas. No option module. . Short instructions Spanish / French / Italian. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Pressure Gauge Block / Booster.
Delivery: See availability
7ML5433-2DC20-1AA0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2DC20-1AA0
Reference: 7ML5433-2DC20-1AA0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens)316L: st/st (1.4435 or 1.4404): DN100 Aseptic/Hygienic clamp according to DIN 11864/11853-3(Form A) Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets): Aluminum, 2 X M20 x 1.5 A: Approvals: General Purpose,CE, CSA, FM, FCC, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Aseptic/hygienic clamp DN100 connection according to DIN 11864-3 (Form A) Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 A: Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, CSA, FM, FCC, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5440-1CA00-1AB2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1CA00-1AB2
Reference: 7ML5440-1CA00-1AB2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5433-2AA20-0AE0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2AA20-0AE0
Reference: 7ML5433-2AA20-0AE0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens): 316L st/st (1.4435 or 1.4404) 2 inch Sanitary Clamp according to ISO 2852 Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Non Sparking, ATEX II 3G Ex nA IIC T4 Gc, CE, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): 2 inch sanitary clamp according to ISO 2852 Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Increased Safety / Non Sparking: ATEX II 3G Ex ec IIC T4 Gc; UKEX II 3G Ex ec IIC T4 Gc; EAC Ex 2Ex nA IIC T4 Gc X; CE, UKCA, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5033-2BA12-2B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BA12-2B
Reference: 7ML5033-2BA12-2B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Smartlinx PROFIBUS DPVO module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 100 ... 230 V AC Number of measurement points: Two-point version Data communication (SmartLinx): SmartLinx PROFIBUS DPV0 module Output relays: 6 relays (4 A-contacts, 2 C contacts), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability

products sitemap