SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5440-0BB00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-0BB00-1BA2
Reference: 7ML5440-0BB00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 40m (131 ft) max range, -40 C degrees to +100 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature: 40 m max. range, -40 ... +100 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5033-2BA10-1B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BA10-1B
Reference: 7ML5033-2BA10-1B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Without module Output relays: 3 relays (2 Form A, 1 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 100 ... 230 V AC Number of measurement points: Two-point version Data communication (SmartLinx): Without module Output relays: 3 relays (2 contacts A, 1 contact C), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability
6DR5112-0EG30-0AA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5112-0EG30-0AA0
Reference: 6DR5112-0EG30-0AA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA with HART-interface; single action; Enclosure Stainless steel without inspection window (not Ex d) . Type of explosion protection: Intrinsic Safety Connection thread el.: M20x1.5 / pneu.: G 1/4 Mechanic Limit Switches (MLS) Qptionally available with device plug M12 (D coding) Order code: -Z D57 without option module . Brief instructions German / English / Chinese . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position regulator, 4...20mA, HART, Ex/nEx, single effect, stainless steel box, without window, for linear pneumatic actuators and fraction of turn. Non-contact position detection (NCS) (wear-free). Not related to P01/P02 pressure sensor option. Standard Protection Mode (Ex): Intrinsic Safety (Ex i). SITRANS I200 Output Isolator, can be ordered separately (7NG4131-1AA00). Cable entry: M20 x 1.5 thread. Pneumatic connection: G1/4 thread. Mechanic Limit Switches (MLS), 2 mechanical limit value switches and 1 digital output. Not suitable for operation with "natural" gas. No option module. . Short instructions English/German/Chinese. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Pressure Gauge Block / Booster.
Delivery: See availability
7ML5433-2AC20-0AN0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2AC20-0AN0
Reference: 7ML5433-2AC20-0AN0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens): 316L st/st (1.4435 or 1.4404) 4 inch Sanitary Clamp according to ISO 2852 Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb , Ex iaD 20 T90 IP67 DIP A20 TA 90C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): 4 inch sanitary clamp according to ISO 2852 Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Increased safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP A20 T A, 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5433-2CC20-0AA0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2CC20-0AA0
Reference: 7ML5433-2CC20-0AA0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens)316L: st/st (1.4435 or 1.4404) DN100 Aseptic/Hygienic flanged to DIN 11864-2 (Form A) Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: General Purpose,CE, CSA, FM, FCC, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Aseptic/hygienic flanged connection DN100 according to DIN 11864-2 Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, CSA, FM, FCC, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5433-2FA20-0AD0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2FA20-0AD0
Reference: 7ML5433-2FA20-0AD0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: 316L st/st (1.4435 or 1.4404) (all types have TFM1600 PTFE lens) Type F (50 mm) Tuchenhagen Varivent EHEDG only Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Non-incendive:CSA/FM Class I, Div. 2, Groups A,B,C,D T5, FCC, Industry Canada Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Type F (50 mm) Tuchenhagen Varivent EHEDG only Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Non-incendive: CSA/FM, Class I, Div. 2, Groups A,B,C,D T5, FCC, Industry Canada Pressure: See pressure/temperature reduction curves in the service instructions
Delivery: See availability
6DR5112-0EN31-0AA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5112-0EN31-0AA0
Reference: 6DR5112-0EN31-0AA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA with HART-interface; single action; Enclosure Stainless steel without inspection window (not Ex d) . Type of explosion protection: Intrinsic Safety Connection thread el.: 1/2" NPT / pneu.: 1/4" NPT Mechanic Limit Switches (MLS) Qptionally available with device plug M12 (D coding) Order code: -Z D57 Analog Output Module (AOM), optionally available with device plug M12 (D coding) (Order code: -Z D53) . Brief instructions German / English / Chinese . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position regulator, 4...20mA, HART, Ex/nEx, single effect, stainless steel box, without window, for linear pneumatic actuators and fraction of turn. Non-contact position detection (NCS) (wear-free). Not related to P01/P02 pressure sensor option. Standard Protection Mode (Ex): Intrinsic Safety (Ex i). SITRANS I200 Output Isolator, can be ordered separately (7NG4131-1AA00). Cable entry: 1/2" NPT thread. Pneumatic connection: 1/4" NPT thread." Mechanic Limit Switches (MLS), 2 mechanical limit value switches and 1 digital output. Not suitable for operation with "natural" gas. Analog Output Module (AOM), Analog Position Feedback 4 ... 20 mA. Order option with fixed connector M12 -Z D53. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions English/German/Chinese. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Pressure Gauge Block / Booster.
Delivery: See availability
7ML5033-2BA10-2B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BA10-2B
Reference: 7ML5033-2BA10-2B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Without module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 100 ... 230 V AC Number of measurement points: Two-point version Data communication (SmartLinx): Without module Output relays: 6 relays (4 A-contacts, 2 C contacts), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability

products sitemap