SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

6DR5626-0EQ13-0AA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5626-0EQ13-0AA0
Reference: 6DR5626-0EQ13-0AA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; FOUNDATION fieldbus operation; double acting; Enclosure stainless steel, flame-proof . Type of explosion protection: Explosion proof Connection thread: el.: M25 x 1,5, / mec.: G1/4, (only for EEx d explosion protection) Digital I/O Module (DIO) Optionally available with device plug M12 (D coding) Order code: -Z D55 Analog Output Module (AOM) and Analog Input Module (AIM) for external position transmitters. Internal potentiometer additionally orderable with -Z K11 . instruction manual: German, English . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position controller, FOUNDATION Fieldbus, Ex/nEx, double acting, stainless steel case, explosion-proof (Ex d), for linear pneumatic actuators and fraction turn. Standard Protection Mode (Ex): Explosion-proof enclosure (Ex d), Dust-proof protection by enclosure (Ex t). Connection thread el.: M25x1.5 / pneu.: G 1/4 Digital I/O Module (DIO), 1 digital input, 3 digital outputs (2 min. or max. limit values, 1 fault warning output) Analog Output Module (AOM) and Analog Input Module (AIM). It does not have internal position detection, although it can be ordered with -Z K11 and or K12 if required. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions English/German/Chinese. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Venting gauge block / Booster.
Delivery: See availability
7ML5440-1BA00-1BB2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1BA00-1BB2
Reference: 7ML5440-1BA00-1BB2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5033-2BA02-1B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BA02-1B
Reference: 7ML5033-2BA02-1B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Single point version Data Communications (Smartlinx): Smartlinx PROFIBUS DPVO module Output relays: 3 relays (2 Form A, 1 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 100 ... 230 V AC Number of measurement points: Version for one point Data communication (SmartLinx): SmartLinx PROFIBUS DPV0 module Output relays: 3 relays (2 A-contacts, 1 C contact), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability
7ML5433-1DC20-1AE0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-1DC20-1AE0
Reference: 7ML5433-1DC20-1AE0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Class 1 Process Connection Types: (all types have TFM1600 PTFE lens)316L: st/st (1.4435 or 1.4404): DN100 Aseptic/Hygienic clamp according to DIN 11864/11853-3(Form A) Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets): Aluminum, 2 X M20 x 1.5 A: Approvals: Non Sparking, ATEX II 3G Ex nA IIC T4 Gc, CE, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL Class I Types of connection to the process (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Aseptic/hygienic clamp DN100 connection according to DIN 11864-3 (Form A) Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 A: Approvals: Increased Safety / Non Sparking: ATEX II 3G Ex ec IIC T4 Gc; UKEX II 3G Ex ec IIC T4 Gc; EAC Ex 2Ex nA IIC T4 Gc X; CE, UKCA, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
6DR5626-0EQ13-0BA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5626-0EQ13-0BA0
Reference: 6DR5626-0EQ13-0BA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; FOUNDATION fieldbus operation; double acting; Enclosure stainless steel, flame-proof . Type of explosion protection: Explosion proof Connection thread: el.: M25 x 1,5, / mec.: G1/4, (only for EEx d explosion protection) Digital I/O Module (DIO) Optionally available with device plug M12 (D coding) Order code: -Z D55 Analog Output Module (AOM) and Analog Input Module (AIM) for external position transmitters. Internal potentiometer additionally orderable with -Z K11 . instructions manual: French, Spanish, Italian . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position controller, FOUNDATION Fieldbus, Ex/nEx, double acting, stainless steel case, explosion-proof (Ex d), for linear pneumatic actuators and fraction turn. Standard Protection Mode (Ex): Explosion-proof enclosure (Ex d), Dust-proof protection by enclosure (Ex t). Connection thread el.: M25x1.5 / pneu.: G 1/4 Digital I/O Module (DIO), 1 digital input, 3 digital outputs (2 min. or max. limit values, 1 fault warning output) Analog Output Module (AOM) and Analog Input Module (AIM). It does not have internal position detection, although it can be ordered with -Z K11 and or K12 if required. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions Spanish / French / Italian. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Venting gauge block / Booster.
Delivery: See availability
6DR5326-0EQ02-0BA4 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5326-0EQ02-0BA4
Reference: 6DR5326-0EQ02-0BA4
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-,3-,4-wire; 4...20mA; double acting; Enclosure stainless steel, flame-proof . Type of explosion protection: Explosion proof Connection thread M25 x 1,5 / G 1/4 (only for EEx d explosion protection) without limit monitor Analog Input Module (AIM) for external position transmitters. Internal potentiometer additionally orderable with -Z K11 Optionally available with device plug M12 (D coding) (Order code: -Z D54). . Instruction manual: French, Spanish, Italian . with mounted pressure gauge made of plastic, IP31, aluminum block, 1/4" NPT aluminum block, 1/4" NPT
SIPART PS2 Intelligent electro-pneumatic position regulator, 4...20mA (3/4 wires), nEx, double acting, stainless steel case, explosion-proof (Ex d), for linear pneumatic actuators and fraction turn. Standard Protection Mode (Ex): Explosion-proof enclosure (Ex d), Dust-proof protection by enclosure (Ex t). Connection thread el.: M25x1.5 / pneu.: G 1/4 No limit monitor. Analog Input Module (AIM) for connecting external position detection systems, e.g. an NCS sensor, a Position Transmitter 6DR4004-1ES/2ES/3ES/4ES or other sensors. It does not have internal position detection, although it can be ordered with -Z K11 and or K12 if required. . Short instructions Spanish / French / Italian. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Double-acting 1/4-18 NPT aluminum gauge block with IP31 plastic pressure gauge (MPa, psi)
Delivery: See availability

products sitemap