SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5432-0BH20-0AN0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5432-0BH20-0AN0
Reference: 7ML5432-0BH20-0AN0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries in the chemical industry. Process Connection Material:Stainless steel 1.4404/1.4435 Flanged Process Connection Types (Stainless steel 1.4404/1.4435): 4" Class 150 ASME B16.5 raised face Communication: 4...20mA HART,start-up at <3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2" NPT Antenna Lens Material: TFM 1600 Flush lens Approvals: Increased Safety: NEPSI Ex e ia mb IIC T4 GA/Gb, Ex iaD 20 T90 IP67 DIP A20 TA 90 C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids and slurries in chemical industry applications. Material, process connection: Stainless steel 1.4404/1.4435 Types of flanged process connection (stainless steel 1.4404/1.4435): 4" Class 150 ASME B16.5 with highlight Communications: 4...20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2" NPT Lens material (antenna): TFM 1600 recessed lens Approvals: Enhanced safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP A20 TA 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5440-1BA00-1AB2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1BA00-1AB2
Reference: 7ML5440-1BA00-1AB2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5033-2BA00-2B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BA00-2B
Reference: 7ML5033-2BA00-2B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Single point version Data Communications (Smartlinx): Without module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 100 ... 230 V AC Number of measurement points: Version for one point Data communication (SmartLinx): Without module Output relays: 6 relays (4 A-contacts, 2 C contacts), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability
7ML5433-1DC20-0AA0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-1DC20-0AA0
Reference: 7ML5433-1DC20-0AA0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Class 1 Process Connection Types: (all types have TFM1600 PTFE lens)316L: st/st (1.4435 or 1.4404): DN100 Aseptic/Hygienic clamp according to DIN 11864/11853-3(Form A) Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: General Purpose,CE, CSA, FM, FCC, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Aseptic/hygienic clamp DN100 connection according to DIN 11864-3 (Form A) Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, CSA, FM, FCC, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5433-2EA20-0AK0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2EA20-0AK0
Reference: 7ML5433-2EA20-0AK0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens): 316L st/st (1.4435 or 1.4404) & 304L st/st (1.4301) DN50 Hygienic nozzle/ slotted nut (instrument side) to DIN 11851 Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Non Sparklng, NEPSI Ex nA IIC T4 Gc Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Types of connection to the process (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404) and stainless steel. 304L (1.4301): Aseptic/hygienic/slotted nut DN50 (instrument side) connection according to DIN 11851 Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Non-sparking: NEPSI Ex nA IIC T4 Gc Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5433-2DB20-0AE0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2DB20-0AE0
Reference: 7ML5433-2DB20-0AE0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens)316L: st/st (1.4435 or 1.4404): DN80 Aseptic/Hygienic clamp according to DIN 11864-3(Form A) Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Non Sparking, ATEX II 3G Ex nA IIC T4 Gc, CE, RED, RCM Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Aseptic/hygienic clamp DN80 connection according to DIN 11864-3 (Form A) Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Increased Safety / Non Sparking: ATEX II 3G Ex ec IIC T4 Gc; UKEX II 3G Ex ec IIC T4 Gc; EAC Ex 2Ex nA IIC T4 Gc X; CE, UKCA, RED, RCM Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5433-2FB20-1AL0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2FB20-1AL0
Reference: 7ML5433-2FB20-1AL0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: 316L st/st (1.4435 or 1.4404) (all types have TFM1600 PTFE lens) Type N (68 mm) Tuchenhagen Varivent EHEDG only Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets): Aluminum, 2 X M20 x 1.5 A: Approvals: Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA 90C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Type N (68 mm) Tuchenhagen Varivent EHEDG only Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 A: Approvals: Intrinsic safety: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5440-0FA00-1BB2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-0FA00-1BB2
Reference: 7ML5440-0FA00-1BB2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 40m (131 ft) max range, -40 C degrees to +100 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature: 40 m max. range, -40 ... +100 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1BA00-1BB1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1BA00-1BB1
Reference: 7ML5440-1BA00-1BB1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): No LDI (User Interface)
Delivery: See availability

products sitemap