SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ML5432-0BH20-1AL0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5432-0BH20-1AL0
Reference: 7ML5432-0BH20-1AL0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries in the chemical industry. Process Connection Material:Stainless steel 1.4404/1.4435 Flanged Process Connection Types (Stainless steel 1.4404/1.4435): 4" Class 150 ASME B16.5 raised face Communication: 4...20mA HART,start-up at <3.6mA - Enclosure (with Cable inlets): Aluminum, 2 X M20 x 1.5 Antenna Lens Material: TFM 1600 Flush lens Approvals: Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA90 C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids and slurries in chemical industry applications. Material, process connection: Stainless steel 1.4404/1.4435 Types of flanged process connection (stainless steel 1.4404/1.4435): 4" Class 150 ASME B16.5 with highlight Communications: 4...20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 Lens material (antenna): TFM 1600 recessed lens Approvals: Intrinsic safety: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
6DR5622-0FS13-0AA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5622-0FS13-0AA0
Reference: 6DR5622-0FS13-0AA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; FOUNDATION fieldbus operation; double action; Enclosure Stainless steel without inspection window . Type of explosion protection: Increased Safety / Nonincendive, Intrinsic Safety Device plug M12 linked to main electronic board (A coding) / 1/4-18 NPT Device plug M12 linked to main electronic board (A coding) / 1/4-18 NPT Digital I/O Module (DIO) Optionally available with device plug M12 (D coding) Order code: -Z D55 Analog Output Module (AOM) and Analog Input Module (AIM) for external position transmitters. Internal potentiometer additionally orderable with -Z K11 . Brief instructions German / English / Chinese . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position regulator, FOUNDATION Fieldbus, Ex/nEx, double acting, stainless steel case, without window, for linear pneumatic actuators and fraction turn. Standard Protection Mode (Ex): Intrinsic Safety (Ex i), Enhanced Safety (Ex e). SITRANS I200 Output Isolator, can be ordered separately (7NG4131-1AA00). M12 fixed connector (A coding) for electronics, 1/4-18 NPT. The M12 overhead connector can be ordered separately with 6DR4004-5A. Digital I/O Module (DIO), 1 digital input, 3 digital outputs (2 min. or max. limit values, 1 "fault warning" output). Analog Output Module (AOM) and Analog Input Module (AIM). It does not have internal position detection, although it can be ordered with -Z K11 and or K12 if required. M12 fixed connector not available. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions English/German/Chinese. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Venting gauge block / Booster.
Delivery: See availability
7ML5440-0CA00-0BB2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-0CA00-0BB2
Reference: 7ML5440-0CA00-0BB2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 40m (131 ft) max range, -40 C degrees to +100 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature: 40 m max. range, -40 ... +100 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-0CA00-1AB1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-0CA00-1AB1
Reference: 7ML5440-0CA00-1AB1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 40m (131 ft) max range, -40 C degrees to +100 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature: 40 m max. range, -40 ... +100 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5033-2AA02-1B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2AA02-1B
Reference: 7ML5033-2AA02-1B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Single point version Data Communications (Smartlinx): Smartlinx PROFIBUS DPVO module Output relays: 3 relays (2 Form A, 1 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Standard box for wall mounting Product is in phase out but still available to order, Consider replacing with 7ML5033-xD Input voltage: 100 ... 230 V AC Number of measurement points: Version for one point Data communication (SmartLinx): SmartLinx PROFIBUS DPV0 module Output relays: 3 relays (2 A-contacts, 1 C contact), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability