SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ME6810-7MC41-3PT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-7MC41-3PT1
Reference: 7ME6810-7MC41-3PT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN900 / Qmax 22902 m3/h(m3), 36 Inch / Qmax 100837 GPM(Gx1 000), 900 / Qmax 549.6 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w.5m) Internal 2 D-cell battery pack installed and disconnected inside meter.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal diameter: DN 900 (36") DN900 / Qmx 22902 m3/h(m3), 36 Inch / Qmx 100837 GPM(Gx10 00), DN900 / Qmx 549.6 Ml/d(Ml) Flange and nominal pressure standard: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-7MC41-3PT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-7MC41-3PT2
Reference: 7ME6810-7MC41-3PT2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN900 / Qmax 22902 m3/h(m3), 36 Inch / Qmax 100837 GPM(Gx1 000), 900 / Qmax 549.6 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w.5m) External battery pack 1.5m power cable with plugs (battery not included).
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal diameter: DN 900 (36") DN900 / Qmx 22902 m3/h(m3), 36 Inch / Qmx 100837 GPM(Gx10 00), DN900 / Qmx 549.6 Ml/d(Ml) Flange and nominal pressure standard: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-7MD31-2CC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-7MD31-2CC0
Reference: 7ME6810-7MD31-2CC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN900 / Qmax 22902 m3/h(m3), 36 Inch / Qmax 100837 GPM(Gx1 000), 900 / Qmax 549.6 Ml/d(Ml) EN 1092-1, PN 16 non PED, Does not conform to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 10m Mounted sensor cables w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal diameter: DN 900 (36") DN900 / Qmx 22902 m3/h(m3), 36 Inch / Qmx 100837 GPM(Gx10 00), DN900 / Qmx 549.6 Ml/d(Ml) Flange and nominal pressure standard: EN 1092-1: PN 16 does not comply with the Pressure Apparatus Directive (DN 700...1200 (28"... 48")) EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: RS 232 serial port with MODBUS RTU Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-7MD31-2CC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-7MD31-2CC1
Reference: 7ME6810-7MD31-2CC1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN900 / Qmax 22902 m3/h(m3), 36 Inch / Qmax 100837 GPM(Gx1 000), 900 / Qmax 549.6 Ml/d(Ml) EN 1092-1, PN 16 non PED, Does not conform to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 10m Mounted sensor cables w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal diameter: DN 900 (36") DN900 / Qmx 22902 m3/h(m3), 36 Inch / Qmx 100837 GPM(Gx10 00), DN900 / Qmx 549.6 Ml/d(Ml) Flange and nominal pressure standard: EN 1092-1: PN 16 does not comply with the Pressure Apparatus Directive (DN 700...1200 (28"... 48")) EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: RS 232 serial port with MODBUS RTU Power: Built-in internal battery
Delivery: See availability

products sitemap