SENSORS AND COMMUNICATIONS

Sensors and communications form the nervous system of any modern industrial automation setup. These components include proximity sensors, photoelectric sensors, inductive sensors, capacitive sensors, ultrasonic sensors, and communication modules like fieldbus couplers, Ethernet switches, and serial converters. Key technical specs to consider are...

7ME6810-8BN41-3PB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-8BN41-3PB4
Reference: 7ME6810-8BN41-3PB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN1200 / Qmax 40715 m3/h(m3), 48 Inch / Qmax 258 MGD(MG), DN1200 / Qmax 977.1 Ml/d(Ml) AS 4087:2004 PN16 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 1200 (48") DN1200 / Qmx 40715 m3/h(m3), 48 Inch / Qmx 258 MGD(MG), DN1200 / Qmx 977.1 Ml/d(Ml) Flange Standard and Nominal Pressure: AS4087: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-8BN41-3PC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-8BN41-3PC0
Reference: 7ME6810-8BN41-3PC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN1200 / Qmax 40715 m3/h(m3), 48 Inch / Qmax 258 MGD(MG), DN1200 / Qmax 977.1 Ml/d(Ml) AS 4087:2004 PN16 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 1200 (48") DN1200 / Qmx 40715 m3/h(m3), 48 Inch / Qmx 258 MGD(MG), DN1200 / Qmx 977.1 Ml/d(Ml) Flange Standard and Nominal Pressure: AS4087: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 232 serial port with MODBUS RTU Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-4BC31-2AC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-4BC31-2AC4
Reference: 7ME6810-4BC31-2AC4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN125 / Qmx 400 m3/h(m3), 5 Inch / Qmx 1761 GPM(Gx100) , DN125 / Qmx 9.6 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal diameter: DN 125 (5") DN125 / Qmx 400 m3/h(m3), 5 Inch / Qmx 1761 GPM(Gx100) , DN125 / Qmx 9.6 Ml/d(Ml) Flange and pressure rating: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power Supply: 115 - 230 V AC Power with Battery Backup and 3m (9.8 ft) Power Cable for the External connection (without battery)
Delivery: See availability

products sitemap