SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN900 / Qmax 22902 m3/h(m3), 36 Inch / Qmax 100837 GPM(Gx1 000), 900 / Qmax 549.6 Ml/d(Ml) EN 1092-1, PN 10, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 900 (36") DN900 / Qmx 22902 m3/h(m3), 36 Inch / Qmx 100837 GPM(Gx10 00), DN900 / Qmx 549.6 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 10 (DN 200...1200 (8"... 48")) EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Sensor Cable with IP68/NEMA6P 6-Pole Connectors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)