SIEMENS

Siemens is a global powerhouse in industrial automation and electrification, present in over 190 countries. Their product portfolio is the most extensive on the market, covering everything from power distribution and control to digital factory solutions. For the electrical engineer, Siemens offers a comprehensive range of industrial control comp...

7ME6820-2YJ05-2AS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2AS2
Reference: 7ME6820-2YJ05-2AS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) External Battery with 1.5m (4.9ft) Patch Cord with Connectors IP68/NEMA 6P, battery not included
Delivery: See availability
7ME6820-2YJ05-2NB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ05-2NB3
Reference: 7ME6820-2YJ05-2NB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pin RS 485 Connectors Standard with MODBUS RTU (with Termination of 12/24 V AC/DC power with battery backup and
Delivery: See availability
7MF8010-1CF31-5HD2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1CF31-5HD2
Reference: 7MF8010-1CF31-5HD2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: clamp connection according DIN 32676: DN 40 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...4 bar abs. overload pressure: 10 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process connection type: flush membrane with front/quick releases: Clamp connection according to DIN 32676: DN 40 Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (internal ventilation for measuring ranges less than 10 bar measuring range: 0...4 bar abs. Overload pressure: 16 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-2QP31-2FE2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2QP31-2FE2
Reference: 7MF8010-2QP31-2FE2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection DIN 11864-1, form-A, with screw necks: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: -1...5 bar overload pressure: 20 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: aseptic fitting DIN 11864-1, Form A, with threaded nozzle: for pipes according to diameter. inch ext. BS 4825 Part 1 (not for connex. NEUMO): 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut Measurement range: -1...5 bar Overload pressure: 30 bar Explosion protection according to ATEX 100 a,
Delivery: See availability
7ME6820-2YJ06-2DD1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ06-2DD1
Reference: 7ME6820-2YJ06-2DD1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder Interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol Built-in internal battery
Delivery: See availability
7ME6820-2YJ07-1BA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ07-1BA1
Reference: 7ME6820-2YJ07-1BA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ08-1NA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ08-1NA3
Reference: 7ME6820-2YJ08-1NA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pin Connectors No Communication Module Additional installed 12/24V AC/DC po
Delivery: See availability
7MF8010-2VP31-5FC1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2VP31-5FC1
Reference: 7MF8010-2VP31-5FC1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, with screw necks W501: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -1...1,5 bar overload pressure: 10 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, with W501 threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. NEUMO): 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar Measurement range: -1...1.5 bar Overload pressure: 16 ba
Delivery: See availability
7ME6820-2YJ08-2DS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ08-2DS2
Reference: 7ME6820-2YJ08-2DS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with antenna cable(5m) External batter
Delivery: See availability
7ME6820-2YJ08-2KS0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ08-2KS0
Reference: 7ME6820-2YJ08-2KS0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Internal Battery (Battery Not Included)
Delivery: See availability
7ME6820-2YJ42-1CC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ42-1CC1
Reference: 7ME6820-2YJ42-1CC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery Incorporated
Delivery: See availability
7ME6820-2YJ42-1PC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ42-1PC2
Reference: 7ME6820-2YJ42-1PC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Power Bank with 1.5 m (4.9 ft) patch cord with IP
Delivery: See availability
7ME6820-2YJ42-2DC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ42-2DC0
Reference: 7ME6820-2YJ42-2DC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 63 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 63 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery ( Battery not included)
Delivery: See availability
7MF8010-2WM31-2FA1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2WM31-2FA1
Reference: 7MF8010-2WM31-2FA1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, clamp-connection W601: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: -1...0 bar overload pressure: 3 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, W601 clamp connection: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut Measurement range: -1...0 bar Overload pressure: 10 bar No explosion protection
Delivery: See availability
7MF8010-2WM31-5DC2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2WM31-5DC2
Reference: 7MF8010-2WM31-5DC2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, clamp-connection W601: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...25 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, W601 clamp connection: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. PNEUMO): 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar measurement range: 0...25 bar Overload pressure: 50 bar E
Delivery: See availability
7ME6820-2YJ43-1LD1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-1LD1
Reference: 7ME6820-2YJ43-1LD1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Encoder Interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol Built-in internal ba
Delivery: See availability
7ME6820-2YJ43-2CC0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-2CC0
Reference: 7ME6820-2YJ43-2CC0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Internal Battery ( Battery not included)
Delivery: See availability
7MF8010-2WP31-2BE1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-2WP31-2BE1
Reference: 7MF8010-2WP31-2BE1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology. with clamp-on remote seal 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: c)quick-release connection/ aseptic-connection: aseptic-connection SUEDMO, clamp-connection W601: for tubes according o.d: tubing inch BS 4825 part 1 (not NEUMO) : 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: 0...600 mbar overload pressure: 3 bar Without explosion protection
Compact pressure transmitter, with separate tubular seal, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: To 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: d) tubular separator seal (threaded connection on both sides)/ Aseptic connections: SUEDMO aseptic fitting, W601 clamp connection: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for connection. NEUMO): 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut measurement range: 0...600 mbar Overload pressure: 6 bar Without explosion protection
Delivery: See availability
7ME6820-2YC00-1DD2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-1DD2
Reference: 7ME6820-2YC00-1DD2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder Interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol External battery with 1.5 m (4.9
Delivery: See availability
7ME6820-2YJ43-2MT4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ43-2MT4
Reference: 7ME6820-2YJ43-2MT4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable(2.5m) 115/230 V
Delivery: See availability
7ME6820-2YJ44-2AS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-2AS2
Reference: 7ME6820-2YJ44-2AS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) External Battery with 1.5m (4.9ft) Patch Cord with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6820-2YJ44-2DD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-2DD0
Reference: 7ME6820-2YJ44-2DD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Rated Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1=160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors Emitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery
Delivery: See availability
7ME6820-2YJ44-2KD4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ44-2KD4
Reference: 7ME6820-2YJ44-2KD4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor Encoder Interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol 115/230 V AC Power with Battery Backup and 3m (9.8 ft) power cord for externa
Delivery: See availability
7ME6820-2YC00-2KA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC00-2KA1
Reference: 7ME6820-2YC00-2KA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 No verification according to OIML R 49 Regional specific version: USA (m3, m3/h, 60 Hz) Transmitter type and mounting: Advanced version integrated into the sensor No additional communication module installed Built-in internal battery
Delivery: See availability
7ME6820-2YJ45-1KD1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ45-1KD1
Reference: 7ME6820-2YJ45-1KD1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor Encoder Interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ45-2MT3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ45-2MT3
Reference: 7ME6820-2YJ45-2MT3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) and analog cable (2.5m) 12/24
Delivery: See availability
7ME6820-2YC03-1AA1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1AA1
Reference: 7ME6820-2YC03-1AA1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors No Additional Communication Module Installed Built-in Internal Battery
Delivery: See availability
7ME6820-2YC03-1KT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1KT0
Reference: 7ME6820-2YC03-1KT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated in Sensor 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and Analog Cable (2.5m ) Internal Battery (Battery Not Included)
Delivery: See availability
7ME6820-2YC03-1PD2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-1PD2
Reference: 7ME6820-2YC03-1PD2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs Encoder Interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol External battery with 1.5 m
Delivery: See availability
7ME6820-2YC03-2BC1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC03-2BC1
Reference: 7ME6820-2YC03-2BC1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Built-in Internal Battery
Delivery: See availability
7ME6820-2YJ47-1DB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ47-1DB3
Reference: 7ME6820-2YJ47-1DB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard & Pressure Rating: ANSI B16.5: Class 150 EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (Terminated 12/24 V AC/DC power supply with batt
Delivery: See availability
7ME6820-2YC04-1BA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-1BA4
Reference: 7ME6820-2YC04-1BA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 115/230 V AC Power with battery backup and 3m (9.8 ft) power
Delivery: See availability
7ME6820-2YC04-1DA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-1DA3
Reference: 7ME6820-2YC04-1DA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24V Power AC/DC with battery backup and 3m (9.8 ft) p
Delivery: See availability
7ME6820-2YC04-1NT0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-1NT0
Reference: 7ME6820-2YC04-1NT0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and analog cable(2.5m) Internal battery (batter
Delivery: See availability
7ME6820-2YC04-2AS4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-2AS4
Reference: 7ME6820-2YC04-2AS4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) 115/230 V AC Power with Battery Backup and Power Cable 3m (9.8 ft) for external connection (without battery)
Delivery: See availability
7ME6820-2YJ47-2CS2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ47-2CS2
Reference: 7ME6820-2YJ47-2CS2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) External battery with 1.5 m (4.9 ft) c
Delivery: See availability
7ME6820-2YJ47-2ES2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ47-2ES2
Reference: 7ME6820-2YJ47-2ES2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable( 5m) External battery with 1.5 m (4.9 ft) c
Delivery: See availability
7ME6820-2YC04-2ED0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC04-2ED0
Reference: 7ME6820-2YC04-2ED0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery not in
Delivery: See availability
7ME6820-2YC05-1AB4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC05-1AB4
Reference: 7ME6820-2YC05-1AB4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Q3/Q1 = 200 MI-001 verification Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: On integrated basic version RS 485 sensors as standard with MODBUS RTU (with line termination) 115/230 V AC power supply with battery backup and cable 3m (9.8 ft) power for external connection (no ba
Delivery: See availability
7ME6820-2YC05-1LB2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC05-1LB2
Reference: 7ME6820-2YC05-1LB2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of External battery with 1.5 m (4.9 ft) connection c
Delivery: See availability
7ME6820-2YJ48-1PT4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ48-1PT4
Reference: 7ME6820-2YJ48-1PT4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5
Delivery: See availability
7ME6820-2YJ48-2BT2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ48-2BT2
Reference: 7ME6820-2YJ48-2BT2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, 5m (16.4 ft) fixed sensor cable with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) and analog
Delivery: See availability
7ME6820-2YJ48-2DS3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YJ48-2DS3
Reference: 7ME6820-2YJ48-2DS3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch ANSI 16.5 Class 150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) 12/2
Delivery: See availability
7ME6820-2YN00-1DA0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN00-1DA0
Reference: 7ME6820-2YN00-1DA0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Internal Battery (Battery No included)
Delivery: See availability
7ME6820-2YN00-1ET1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN00-1ET1
Reference: 7ME6820-2YN00-1ET1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) and analog cable(2.5m) Built-in internal battery
Delivery: See availability
7ME6820-2YN00-2EC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN00-2EC2
Reference: 7ME6820-2YN00-2EC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU External Battery with 1.5 m (4.9 ft) patch cord with IP68/NEMA 6P connector
Delivery: See availability
7MF8010-1HP31-5HA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1HP31-5HA2
Reference: 7MF8010-1HP31-5HA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: SMS-Norm with screw necks: 2 inch PN25 Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: 0...1 bar abs. overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Process Connection Type: Flush Membrane with Front/Quick Releases: SMS Standard with Threaded Nozzle: 2 inches Filling Fluid: FDA Listed Food Output Signal: 4-20 mA Box Version (Stainless Steel 1.4404)/Electrical Connection: Stainless Steel Field Box with Cable Grommet, IP67(Small) (Indoor Venting for Measurement Ranges Less Than 10 Bar Measurement Range: 0...1 bar abs. Overload pressure: 3 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC05-2AB0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC05-2AB0
Reference: 7ME6820-2YC05-2AB0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 200 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor Serial RS 485 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 200 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On RS 485 Integrated Basic Version Sensors as Standard with MODBUS RTU (with Line Termination) Internal Battery (Battery Not Included)
Delivery: See availability
7ML5632-8DA10-0CD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DA10-0CD0
Reference: 7ML5632-8DA10-0CD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof CE, UKCA, RCM, ATEX, UKEX II 1/2D Ex ia/tb Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Compact design 98 mm (3.86") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ML5632-8DA10-1KC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DA10-1KC0
Reference: 7ML5632-8DA10-1KC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose CSA, FM, CE, UKCA, RCM with WHG approval Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Compact design 98 mm (3.86") Thermal insulation: With thermal insulation (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) with WHG approval Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68
Delivery: See availability
7ME6820-2YC06-1DC3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-1DC3
Reference: 7ME6820-2YC06-1DC3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU 12/24 Power V AC/DC with battery backup and 3m (9.8 ft) power cabl
Delivery: See availability
7ME6820-2YC06-1MA2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-1MA2
Reference: 7ME6820-2YC06-1MA2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Wired External Battery 1.5 m (4.9 ft) connection with
Delivery: See availability
7ME6820-2YN00-2NA2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN00-2NA2
Reference: 7ME6820-2YN00-2NA2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: AS4087: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed Wired External Battery 1.5 m (4.9 ft) connection with IP68/NEM
Delivery: See availability
7MF8010-1KF31-3FA2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1KF31-3FA2
Reference: 7MF8010-1KF31-3FA2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company) d= 50, for varivent housing DN 25 and 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: -1...0 bar overload pressure: 3 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick closures: Varivent connection (Tuchenhagen brand): d = 50, for Varivent DN 25 box and 1 inch Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: -1...0 bar Overload pressure: 10 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7MF8010-1KL31-2DB2 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1KL31-2DB2
Reference: 7MF8010-1KL31-2DB2
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: quick-release connection: varivent-connection (Tuchenhagen company): d=68, for varivent- housing DN 40...DN 125, and 1 1/2 inch...6 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: 0...16 bar overload pressure: 60 bar With Ex-protection according ATEX 100a, II 2 G, EEx ib IIC T6
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/quick releases: Varivent connection (Tuchenhagen brand): d = 68, for Varivent DN 40...DN 125 box, and 1 1/2 inches... 6 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut measurement range: 0...16 bar Overload pressure: 50 bar Explosion protection according to ATEX 100 a, II 2 G, EEx ib IIC T6
Delivery: See availability
7ME6820-2YC06-2ET2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC06-2ET2
Reference: 7ME6820-2YC06-2ET2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 250 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 250 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and analog cable(2.5m) External battery with 1.5 m (4.
Delivery: See availability
7ME6820-2YC07-1LB3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC07-1LB3
Reference: 7ME6820-2YC07-1LB3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Termination of 12/24 V AC/DC power with battery backup and 3m (9
Delivery: See availability
7ME6820-2YC07-2AA4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC07-2AA4
Reference: 7ME6820-2YC07-2AA4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 100 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Q3/Q1 = 100 MI-001 vérification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors No Additional Communication Module Installed 115/230V AC Power with Battery Backup and 3m (9.8 ft) Power Cord for external connection (without battery)
Delivery: See availability
7ME6820-2YN02-1KS4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YN02-1KS4
Reference: 7ME6820-2YN02-1KS4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch AS 4087 PN16 EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Q3/Q1 = 63 MI-001 verification Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: AS4087: PN 16 EPDM coating and Hastelloy electrodes, Corrosion resistant coating category C4 Q3/Q1 = 63 MI-001 verification Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Advanced version integrated in the sensor 3G / UMTS module for MAG8000 with antenna cable(5m) 115/230 V AC power with battery backup and power cable 3m (9.8 ft) for external connection (without battery)
Delivery: See availability
7ML5632-8DD01-0FB0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DD01-0FB0
Reference: 7ML5632-8DD01-0FB0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 500 mm (19.69") Thermal Isolator: Without thermal isolator Wetted Seals: FFKM (for process temperatures above -20 C (-4 F)) Probe Material: 316L Stainless Steel with PPS probe body Approvals: Dust Ignition Proof With IS Probe CSA/ FM Class II, III Div.1 Gr. E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 500 mm (19.69") Thermal insulator: Without thermal insulation Process side seals: FFKM (for process temperatures above -20 °C (-4 F)) Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy C
Delivery: See availability
7MF8010-1PM31-4GB1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PM31-4GB1
Reference: 7MF8010-1PM31-4GB1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: -1...15 bar overload pressure: 60 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small Measuring range: –1...15 bar Overload pressure: 50 bar No explosion protection
Delivery: See availability
7MF8010-1PM31-5FD1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PM31-5FD1
Reference: 7MF8010-1PM31-5FD1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -1...3 bar overload pressure: 20 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP67(small) (indoor ventilation for measurement ranges less than 10 bar Measurement range: -1...3 bar Overload pressure: 16 bar No explosion protection
Delivery: See availability
7MF8010-1PN31-4CE1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PN31-4CE1
Reference: 7MF8010-1PN31-4CE1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 1 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...6 bar overload pressure: 60 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 1 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...6 bar Overload pressure: 30 bar No explosion protection
Delivery: See availability
7ME6820-2YC08-1DB4 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC08-1DB4
Reference: 7ME6820-2YC08-1DB4
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy electrodes, corrosion-resistant coating of category C4 Acc. to OIML R49 Q3/Q1 = 250, without sealing Region version: Europe Display: m3, m3/h based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Approval/Verification: No Verification to OIML R 49 (Q3/Q1 = 250) Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors as Standard with MODBUS RTU (with line termination) 115/230
Delivery: See availability
7ME6820-2YC40-1KD0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC40-1KD0
Reference: 7ME6820-2YC40-1KD0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version compact Transmitter on sensor Encoder Interface Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 No verification according to OIML R 49 Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Advanced version integrated in the sensor Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Internal battery (battery not included)
Delivery: See availability
7ML5632-8DF00-0HD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DF00-0HD0
Reference: 7ML5632-8DF00-0HD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulator: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ML5632-8DF10-1HC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DF10-1HC0
Reference: 7ML5632-8DF10-1HC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1000 mm (39.37") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 1000 mm (39.37") Thermal insulator: With thermal insulator (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe Approvals: General Purpose (CSA, FM) Enclosure & Lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68
Delivery: See availability
7MF8010-1PP31-2FC1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PP31-2FC1
Reference: 7MF8010-1PP31-2FC1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65 Measuring range: -1...1,5 bar overload pressure: 10 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. ext. in inches BS 4825 part 1 (not for NEUMO) : 2 inches Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Polyamide fixing fitting nut Measuring range: -1...1.5 bar Overload pressure: 16 bar No explosion protection
Delivery: See availability
7MF8010-1PP31-5EB1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PP31-5EB1
Reference: 7MF8010-1PP31-5EB1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP67 Measuring range: -160...0 mbar overload pressure: 1 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. ext. in inches BS 4825 part 1 (not for NEUMO) : 2 inches Filling Fluid: FDA Listed Food Output Signal: 4-20 mA Box Version (Stainless Steel 1.4404)/Electrical Connection: Stainless Steel Field Box with Grommet, IP67(Small) (Indoor Venting for Measuring Ranges Less Than 10 Bar Measuring Range: -160...0 mbar Overload pressure: 2 bar No explosion protection
Delivery: See availability
7MF8010-1PQ31-3DC1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PQ31-3DC1
Reference: 7MF8010-1PQ31-3DC1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 2 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: housing with plug M12, IP65, union nut stainless stell Measuring range: 0...25 bar overload pressure: 60 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 2 1/2 in. Filling fluid: FDA listed foods output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Box with M12 IP65 round connector Stainless steel fixing fitting nut. Measuring range: 0...25 bar Overload pressure: 50 bar No explosion protection
Delivery: See availability
7MF8010-1PQ31-4DB1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1PQ31-4DB1
Reference: 7MF8010-1PQ31-4DB1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with slotted union nut: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 2 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...16 bar overload pressure: 60 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with fitting nut: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 2 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...16 bar Overload pressure: 50 bar No explosion protection
Delivery: See availability
7ME6820-2YC40-1MC2 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC40-1MC2
Reference: 7ME6820-2YC40-1MC2
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration (without initial verification) Region version: Europe Display: m3, m3/h based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 1.5m power cable with plugs for external batterypack (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 No Verification to OIML R 49 Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Battery External with 1.5 m (4.9 ft) connection cable wi
Delivery: See availability
7ME6820-2YC40-2DB0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC40-2DB0
Reference: 7ME6820-2YC40-2DB0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 No Verification to OIML R 49 Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (with Line termination) Internal battery (battery not included)
Delivery: See availability
7ME6820-2YC40-2LT1 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC40-2LT1
Reference: 7ME6820-2YC40-2LT1
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration (without initial verification) Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and pressure rating standard: EN 1092-1: PN 16 EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 No verification according to OIML R 49 Regional specific version: USA (m3, m3/h, 60 Hz) Transmitter type and mounting: Advanced version separated, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with cable Antenna(5m) and analog cable(2.5m) Built-in inter
Delivery: See availability
7ML5632-8DH00-1JD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DH00-1JD0
Reference: 7ML5632-8DH00-1JD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1350 mm (53.15") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: General Purpose (CSA, FM, CE, UKCA, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1350 mm (53.15") Thermal insulation: Without thermal insulation Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: General purpose (CE, C-TICK) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68
Delivery: See availability
7ML5632-8DK00-1FD0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DK00-1FD0
Reference: 7ML5632-8DK00-1FD0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1750 mm (68.90") Thermal Isolator: Without thermal isolator Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Dust Ignition Proof With IS Probe CSA/ FM Class II, III Div.1 Gr. E, F, G T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1750 mm (68.90") Thermal insulator: Without thermal insulator Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Ex protection for dust with intrinsically safe (IS) probe CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68
Delivery: See availability
7ME6820-2YC43-2NC3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC43-2NC3
Reference: 7ME6820-2YC43-2NC3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 80 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 20m Mounted sensor cables w. plugs Seriel RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange and Pressure Rating Standard: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 80 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 20 m (65.6) on Sensor with IP68/NEMA6P 6-Pole Connectors RS 232 Serial Port with MODBUS RTU Power Supply 12/24V AC/DC with battery backup and 3m (9.8
Delivery: See availability
7ML5632-8DK20-1GA0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DK20-1GA0
Reference: 7ML5632-8DK20-1GA0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 1750 mm (68.90") Thermal Isolator: Remote mount electronics with 2 m (79") of cable and mouting bracket Wetted Seals: FKM Probe Material: 316L Stainless Steel with PVDF probe body Approvals: Explosion Proof Enclosure With IS Probe CSA/ FM Class I, II, III Div.1 Gr..
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from process connection face): Rod extension, 1750 mm (68.90") Thermal insulator: Separate electronics with 2 m (79") cable and mounting bracket Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PVDF probe approvals: Explosion-proof enclosure with intrinsically safe (IS) CSA/FM probe Class I, Div. 1, Tam. A, B, C, D CSA/FM Class II, Div. 1, tam. E, F, G CSA/FM Class
Delivery: See availability
7ML5632-8DL10-0JC0 SIEMENS Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects le..

SIEMENS

Manufacturer Code: 7ML5632-8DL10-0JC0
Reference: 7ML5632-8DL10-0JC0
Catalog Number: -
Pointek CLS200 RF Capacitance point level switch, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Sanitary 316L (1.4404) stainless steel: 2 1/2" sanitary fitting clamp Probe length: (length from process connection face): Extended rod, 2000 mm (78.74") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: General Purpose (CSA, FM, CE, UKCA, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 .
. Pointek CLS200 RF Capacitive Level Switch, Variant with Sanitary Rod. Level and level/interface detection of liquids, solids, slurries and foam. Insertion length 5.5 m (18.04 ft) adjustable, sensitivity adjustable, with the ability to ignore build-up in the probe. Process connection: Stainless steel. Sanitary No. Mat. 1.4404/316L 2 1/2" Sanitary Clamp Special Version: (length measured from the process connection face): Rod extension, 2000 mm (78.74") Thermal insulation: With thermal insulator (for process connection temperatures above +85 °C (+185 F)) Seals on the process side: FKM Probe material: stainless steel, mat no. 1.4404/316L with PPS probe Approvals: General purpose (CE, C-TICK) Case and lid: Aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68
Delivery: See availability
7MF8010-1QQ31-4CD1 SIEMENS SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmac..

SIEMENS

Manufacturer Code: 7MF8010-1QQ31-4CD1
Reference: 7MF8010-1QQ31-4CD1
Catalog Number: -
SITRANS P Transmitter Compact for pressure and absolut pressure for food, pharmaceu- ticals and biotechnology, with diaphragm flush at front. 2-wire system, process tempera- ture up to 140 deg. Cel., accuracy 0.2 % of f.s.v. output signal: 4...20 mA, Process connection: Front-flush diaphragm/aseptic connection DIN 11864-1, form A, with screw necks: for tubes according o:d: tubing inch bs 4825 part 1 (not NEUMO): 2 1/2 inch Filling liquid: liquid FDA approved Output signal : 4-20 mA Housing(stainless steel1.4404)/ electrical connection: field housing stainless steel with cable gland, IP65 Measuring range: 0...4 bar overload pressure: 20 bar Without explosion protection
Compact pressure transmitter, with flush membrane, for the food, pharmaceutical and biotechnology industries, model SITRANS P, with: Connection: 2 wires. Maximum process temperature: Up to 140 C. Accuracy: 0.3%. Output signal: 4 to 20 mA. Type of connection to the process: flush membrane with front/ Aseptic connections: aseptic fitting DIN 11864-1, form A, with threaded nozzle: for pipes according to diameter. Inch ext. BS 4825 Part 1 (not for NEUMO) : 2 1/2 in. Filling fluid: FDA listed food output signal: 4-20 mA Box version (stainless steel 1.4404)/electrical connection: Stainless steel field box with cable grommet, IP65 (small measuring range: 0...4 bar Overload pressure: 16 bar No explosion protection
Delivery: See availability
7ME6820-2YC44-2MB0 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-2MB0
Reference: 7ME6820-2YC44-2MB0
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Serial RS 485 interface module Modbus RTU Internal battery supply (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole RS 485 Connectors Standard with MODBUS RTU (Terminated Internal battery (battery not included)
Delivery: See availability
7ME6820-2YC44-2PA3 SIEMENS SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custo..

SIEMENS

Manufacturer Code: 7ME6820-2YC44-2PA3
Reference: 7ME6820-2YC44-2PA3
Catalog Number: -
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flowmeter, flanged, custody transfer approved. Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and custody transfer metering. . DN50, 2 Inch EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Q3/Q1 = 160 MI-001 verification Region version: USA Display: m3, m3/h based 60 Hz filter Advanced version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 CT Battery-operated electromagnetic flow sensor, with flange, approved for transactions with verification. Suitable for continuous measurement of the volumetric flow of liquids (conductors) for water applications in the sectors of collection, distribution, billing of consumption and transactions with verification. . DN50, 2 Inch Flange Standard and Pressure Rating: EN 1092-1: PN 16 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Q3/Q1 = 160 MI-001 Verification Regional Specific Version: USA (m3, m3/h, 60 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors No Additional Communication Module Installed 12/24 Power V AC/DC with battery backup and 3m
Delivery: See availability

products sitemap

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.