SIEMENS

Siemens is a global powerhouse in industrial automation and electrification, present in over 190 countries. Their product portfolio is the most extensive on the market, covering everything from power distribution and control to digital factory solutions. For the electrical engineer, Siemens offers a comprehensive range of industrial control comp...

7ML5440-1FB00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1FB00-1BA2
Reference: 7ML5440-1FB00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
6DR5622-0GR03-0AA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5622-0GR03-0AA0
Reference: 6DR5622-0GR03-0AA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; FOUNDATION fieldbus operation; double action; Enclosure Stainless steel without inspection window . Type of explosion protection: Increased Safety / Nonincendive Device plug M12 linked to main electronic board (A coding) / G ¼ Device plug M12 linked to main electronic board (A coding) / G ¼ without limit monitor Analog Output Module (AOM) and Analog Input Module (AIM) for external position transmitters. Internal potentiometer additionally orderable with -Z K11 . Brief instructions German / English / Chinese . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position regulator, FOUNDATION Fieldbus, Ex/nEx, double acting, stainless steel case, without window, for linear pneumatic actuators and fraction turn. Standard Protection Mode (Ex): Increased Safety (Ex e). Fixed M12 connector (A coding) for electronics, G1/4. The M12 overhead connector can be ordered separately with 6DR4004-5A. No limit monitor. Analog Output Module (AOM) and Analog Input Module (AIM). It does not have internal position detection, although it can be ordered with -Z K11 and or K12 if required. M12 fixed connector not available. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions English/German/Chinese. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Venting gauge block / Booster.
Delivery: See availability
7ML5440-1DA00-1BB1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1DA00-1BB1
Reference: 7ML5440-1DA00-1BB1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5033-2BB00-2B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BB00-2B
Reference: 7ML5033-2BB00-2B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 12 to 30 VDC Number of measurement points: Single point version Data Communications (Smartlinx): Without module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 12 ... 30 V DC Number of Measurement Points: Version for One Point Data Communication (SmartLinx): Without Module Output Relays: 6 Relays (4 A-Contacts, 2 C-Contacts), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability
7ML5433-2FA20-1AN0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2FA20-1AN0
Reference: 7ML5433-2FA20-1AN0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: 316L st/st (1.4435 or 1.4404) (all types have TFM1600 PTFE lens) Type F (50 mm) Tuchenhagen Varivent EHEDG only Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets): Aluminum, 2 X M20 x 1.5 A: Approvals: Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb , Ex iaD 20 T90 IP67 DIP A20 TA 90C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Type F (50 mm) Tuchenhagen Varivent EHEDG only Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 A: Approvals: Enhanced safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP A20 T A, 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
6DR5622-0GR03-0AA2 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5622-0GR03-0AA2
Reference: 6DR5622-0GR03-0AA2
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; FOUNDATION fieldbus operation; double action; Enclosure Stainless steel without inspection window . Type of explosion protection: Increased Safety / Nonincendive Device plug M12 linked to main electronic board (A coding) / G ¼ Device plug M12 linked to main electronic board (A coding) / G ¼ without limit monitor Analog Output Module (AOM) and Analog Input Module (AIM) for external position transmitters. Internal potentiometer additionally orderable with -Z K11 . Brief instructions German / English / Chinese . with mounted pressure gauge made of plastic, IP31, aluminum block, G1/4 aluminum block, G1/4
SIPART PS2 Intelligent electro-pneumatic position regulator, FOUNDATION Fieldbus, Ex/nEx, double acting, stainless steel case, without window, for linear pneumatic actuators and fraction turn. Standard Protection Mode (Ex): Increased Safety (Ex e). Fixed M12 connector (A coding) for electronics, G1/4. The M12 overhead connector can be ordered separately with 6DR4004-5A. No limit monitor. Analog Output Module (AOM) and Analog Input Module (AIM). It does not have internal position detection, although it can be ordered with -Z K11 and or K12 if required. M12 fixed connector not available. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions English/German/Chinese. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). G1/4 aluminium gauge block, double acting with IP31 plastic pressure gauge (MPa, bar)
Delivery: See availability
7ML5440-1DA00-1BB2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1DA00-1BB2
Reference: 7ML5440-1DA00-1BB2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1FA00-0AB1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1FA00-0AB1
Reference: 7ML5440-1FA00-0AB1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): No LDI (User Interface)
Delivery: See availability

products sitemap

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.