SIEMENS

Siemens is a global powerhouse in industrial automation and electrification, present in over 190 countries. Their product portfolio is the most extensive on the market, covering everything from power distribution and control to digital factory solutions. For the electrical engineer, Siemens offers a comprehensive range of industrial control comp...

7ML5440-1DA00-0BB1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1DA00-0BB1
Reference: 7ML5440-1DA00-0BB1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-0FA00-0BB2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-0FA00-0BB2
Reference: 7ML5440-0FA00-0BB2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 40m (131 ft) max range, -40 C degrees to +100 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature: 40 m max. range, -40 ... +100 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): With LDI (User Interface)
Delivery: See availability
6DR5622-0GR11-0AA0 SIEMENS SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn a..

SIEMENS

Manufacturer Code: 6DR5622-0GR11-0AA0
Reference: 6DR5622-0GR11-0AA0
Catalog Number: -
SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; FOUNDATION fieldbus operation; double action; Enclosure Stainless steel without inspection window . Type of explosion protection: Increased Safety / Nonincendive Device plug M12 linked to main electronic board (A coding) / G ¼ Device plug M12 linked to main electronic board (A coding) / G ¼ Digital I/O Module (DIO) Optionally available with device plug M12 (D coding) Order code: -Z D55 Analog Output Module (AOM), optionally available with device plug M12 (D coding) (Order code: -Z D53) . Brief instructions German / English / Chinese . without mounted pressure gauge block
SIPART PS2 Intelligent electro-pneumatic position regulator, FOUNDATION Fieldbus, Ex/nEx, double acting, stainless steel case, without window, for linear pneumatic actuators and fraction turn. Standard Protection Mode (Ex): Increased Safety (Ex e). Fixed M12 connector (A coding) for electronics, G1/4. The M12 overhead connector can be ordered separately with 6DR4004-5A. Digital I/O Module (DIO), 1 digital input, 3 digital outputs (2 min. or max. limit values, 1 "fault warning" output). Analog Output Module (AOM), Analog Position Feedback 4 ... 20 mA. Order option with fixed connector M12 -Z D53. Separately orderable SITRANS I100 insulating power supply (7NG4124-1AA00). . Short instructions English/German/Chinese. Standard / Fail-Safe - Purge actuator in case of auxiliary power failure (single effect only). Without Venting gauge block / Booster.
Delivery: See availability
7ML5432-0GC20-0AM0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5432-0GC20-0AM0
Reference: 7ML5432-0GC20-0AM0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries in the chemical industry. Process Connection Material:Stainless steel 1.4404/1.4435 Flanged Process Connection Types (Stainless steel 1.4404/1.4435): DN100 PN10/16 EN 1092-1 type B1 raised face Communication: 4...20mA HART,start-up at <3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2" NPT Antenna Lens Material: TFM 1600 Flush lens Approvals: Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP A20 TA90 C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids and slurries in chemical industry applications. Material, process connection: Stainless steel 1.4404/1.4435 Types of flanged process connection (stainless steel 1.4404/1.4435): DN100 PN10/16 EN 1092-1 type B1 with highlight Communications: 4...20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2" NPT Lens material (antenna): TFM 1600 recessed lens Approvals: Flameproof: NEPSI Ex d ia mb IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP A20 TA 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5440-1DA00-0BB2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1DA00-0BB2
Reference: 7ML5440-1DA00-0BB2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): With LDI (User Interface)
Delivery: See availability

products sitemap

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.