SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN150 / Qmx 629 m3/h(m3), 6 Inch / Qmx 2769 GPM(Gx100) , DN150 / Qmx 15.12 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 150 (6") DN150 / Qmx 629 m3/h(m3), 6 Inch / Qmx 2769 GPM(Gx100) , DN150 / Qmx 15.12 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter Type and Mounting: Separate Basic Version, Fixed Cable Do - 30 m (98.4) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: No additional communication modules installed Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)