SIEMENS

Siemens is a global powerhouse in industrial automation and electrification, present in over 190 countries. Their product portfolio is the most extensive on the market, covering everything from power distribution and control to digital factory solutions. For the electrical engineer, Siemens offers a comprehensive range of industrial control comp...

7ME6810-2DJ31-3KC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KC4
Reference: 7ME6810-2DJ31-3KC4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 232 serial port with MODBUS RTU Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ31-3KD0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KD0
Reference: 7ME6810-2DJ31-3KD0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated in the sensor Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ31-3KD1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KD1
Reference: 7ME6810-2DJ31-3KD1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated in the sensor Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ31-3KD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KD2
Reference: 7ME6810-2DJ31-3KD2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated in the sensor Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ31-3KD3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KD3
Reference: 7ME6810-2DJ31-3KD3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated in the sensor Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ31-3KD4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KD4
Reference: 7ME6810-2DJ31-3KD4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ31-3KS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KS1
Reference: 7ME6810-2DJ31-3KS1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor 3G / UMTS module for MAG8000 with antenna cable(5m) Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ31-3KS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KS2
Reference: 7ME6810-2DJ31-3KS2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor 3G / UMTS module for MAG8000 with antenna cable(5m) Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ31-3KS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KS3
Reference: 7ME6810-2DJ31-3KS3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type and Mount: Advanced Version Integrated in Sensor 3G/UMTS Module for MAG8000 with Antenna Cable (5m) Power Supply: 12/24V AC/DC Power with Battery Backup and 3m (9.8ft) Power Cable for External Connection (without Battery)
Delivery: See availability
7ME6810-2DJ31-3KS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KS4
Reference: 7ME6810-2DJ31-3KS4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter and mounting type: Advanced version integrated into the sensor 3G / UMTS module for MAG8000 with antenna cable (5m) Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ31-3KT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KT0
Reference: 7ME6810-2DJ31-3KT0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated into the sensor 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ31-3KT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KT1
Reference: 7ME6810-2DJ31-3KT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated in the sensor 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ31-3KT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KT2
Reference: 7ME6810-2DJ31-3KT2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated in the sensor 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ31-3KT3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KT3
Reference: 7ME6810-2DJ31-3KT3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor 3G/UMTS module for MAG8000 with antenna cable (5m) and analog cable (2.5m ) Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ31-3KT4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3KT4
Reference: 7ME6810-2DJ31-3KT4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor 3G/UMTS module for MAG8000 with antenna cable (5m) and analog cable (2.5m ) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ31-3MA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MA0
Reference: 7ME6810-2DJ31-3MA0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: No additional communication module installed Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ31-3MA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MA1
Reference: 7ME6810-2DJ31-3MA1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: No additional communication module installed Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ31-3MA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MA2
Reference: 7ME6810-2DJ31-3MA2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: No Additional Communication Module Installed Power: External Battery with 1.5 m (4.9 ft) Patch Cable with IP68/NEMA 6P Connectors, Battery not included
Delivery: See availability
7ME6810-2DJ31-3MA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MA3
Reference: 7ME6810-2DJ31-3MA3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type & Mount: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pin Connectors Transfer Interface: No additional communication module installed Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ31-3MA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MA4
Reference: 7ME6810-2DJ31-3MA4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type & Mount: Separate Advanced Version, Fixed Cable C - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: No Additional Communication Module Installed Power: 115 - 230 V AC Power with Battery Backup and 3m (9.8 ft) Power Cable for External Connection (Without Battery)
Delivery: See availability
7ME6810-2DJ31-3MC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MC0
Reference: 7ME6810-2DJ31-3MC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type and Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power Supply: Internal Battery (Battery Not Included)
Delivery: See availability
7ME6810-2DJ31-3MC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MC3
Reference: 7ME6810-2DJ31-3MC3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type & Mount: Separate Advanced Version, Fixed Cable C - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ31-3MC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MC4
Reference: 7ME6810-2DJ31-3MC4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type & Mount: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power: 115 - 230 V AC Power with Battery Backup and 3m (9.8 ft) Power Cable for External Connection (without Battery)
Delivery: See availability
7ME6810-2DJ31-3MS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MS0
Reference: 7ME6810-2DJ31-3MS0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ31-3MS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MS1
Reference: 7ME6810-2DJ31-3MS1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ31-3MS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MS2
Reference: 7ME6810-2DJ31-3MS2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-2DJ31-3MS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MS3
Reference: 7ME6810-2DJ31-3MS3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS MAG8000 Module with Antenna Cable (5m) Power: 12/24V AC/DC Power with Battery Backup and 3m (9.8 ft) Power Cable for External Connection (without Battery)
Delivery: See availability
7ME6810-2DJ31-3MS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MS4
Reference: 7ME6810-2DJ31-3MS4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type & Mounting: Separate Advanced Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Power: 115 - 230 V AC Power with Battery Backup and 3m (9.8 ft) Power Cable for External Connection (Without Battery)
Delivery: See availability
7ME6810-2DJ31-3MT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MT0
Reference: 7ME6810-2DJ31-3MT0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ31-3MT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MT1
Reference: 7ME6810-2DJ31-3MT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on the sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ31-3MT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MT2
Reference: 7ME6810-2DJ31-3MT2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-2DJ31-3MT3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ31-3MT3
Reference: 7ME6810-2DJ31-3MT3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 10m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 10 m (32.8) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) and analog cable (2.5m ) Power supply: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-1AD1 SIEMENS Water meter SITRANS FM MAG 8000 DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), D..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-1AD1
Reference: 7ME6810-2DJ41-1AD1
Catalog Number: -
Water meter SITRANS FM MAG 8000 DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Europe (m3, m3/h, 50 Hz) Type of transmitter and mounting: In integrated basic version sensors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ41-1AD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-1AD2
Reference: 7ME6810-2DJ41-1AD2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Europe (m3, m3/h, 50 Hz) Type of transmitter and mounting: On integrated basic version sensors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ41-1BT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-1BT1
Reference: 7ME6810-2DJ41-1BT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ41-1BT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-1BT2
Reference: 7ME6810-2DJ41-1BT2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: External battery with 1.5m (4.9ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-2DJ41-2AA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AA0
Reference: 7ME6810-2DJ41-2AA0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: No Additional Communication Module Installed Power: Internal Battery (Battery Not Included)
Delivery: See availability
7ME6810-2DJ41-2AA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AA1
Reference: 7ME6810-2DJ41-2AA1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: No additional communication module installed Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ41-2AA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AA2
Reference: 7ME6810-2DJ41-2AA2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: No additional communication module installed Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ41-2AA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AA3
Reference: 7ME6810-2DJ41-2AA3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: No additional communication module installed Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2AA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AA4
Reference: 7ME6810-2DJ41-2AA4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: No additional communication module installed Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2AB0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AB0
Reference: 7ME6810-2DJ41-2AB0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: RS 485 standard with MODBUS RTU (with line termination) Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ41-2AB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AB2
Reference: 7ME6810-2DJ41-2AB2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: RS 485 standard with MODBUS RTU (with line termination) Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ41-2AB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AB3
Reference: 7ME6810-2DJ41-2AB3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: RS 485 standard with MODBUS RTU (with line termination) Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2AB4 SIEMENS Water meter SITRANS FM MAG 8000 DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), D..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AB4
Reference: 7ME6810-2DJ41-2AB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Base Version Sensors Transfer Interface: RS 485 standard with MODBUS RTU (with line termination) Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2AC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AC0
Reference: 7ME6810-2DJ41-2AC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power: Internal Battery (Battery Not Included)
Delivery: See availability
7ME6810-2DJ41-2AC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AC1
Reference: 7ME6810-2DJ41-2AC1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power Supply: Built-in Internal Battery
Delivery: See availability
7ME6810-2DJ41-2AC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AC2
Reference: 7ME6810-2DJ41-2AC2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ41-2AC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AC3
Reference: 7ME6810-2DJ41-2AC3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2AC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AC4
Reference: 7ME6810-2DJ41-2AC4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power: 115 - 230 V AC Power with Battery Backup and 3m (9.8 ft) Power Cord for External Connection (without Battery)
Delivery: See availability
7ME6810-2DJ41-2AD0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AD0
Reference: 7ME6810-2DJ41-2AD0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ41-2AD3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AD3
Reference: 7ME6810-2DJ41-2AD3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2AD4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AD4
Reference: 7ME6810-2DJ41-2AD4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2AS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AS0
Reference: 7ME6810-2DJ41-2AS0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Power: Internal Battery (Battery Not Included)
Delivery: See availability
7ME6810-2DJ41-2AS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AS1
Reference: 7ME6810-2DJ41-2AS1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Power: Built-in Internal Battery
Delivery: See availability
7ME6810-2DJ41-2AS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AS2
Reference: 7ME6810-2DJ41-2AS2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Base Version Sensors 3G/UMTS MAG8000 Module with Antenna Cable (5m) Power: External Battery with 1.5 m (4.9 ft) Patch Cord with IP68/NEMA 6P Connectors, Battery Not Included
Delivery: See availability
7ME6810-2DJ41-2AS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AS3
Reference: 7ME6810-2DJ41-2AS3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: On Integrated Basic Version Sensors 3G/UMTS MAG8000 Module with Antenna Cable (5m) Power: 12/24V AC/DC Power with Battery Backup and 3m (9.8ft) Power Cable for External Connection (No Battery)
Delivery: See availability
7ME6810-2DJ41-2AS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AS4
Reference: 7ME6810-2DJ41-2AS4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors 3G/UMTS MAG8000 Module with Antenna Cable (5m) Power: 115 - 230 V AC Power with Battery Backup and 3m (9.8 ft) Power Cable for External Connection (without Battery)
Delivery: See availability
7ME6810-2DJ41-2AT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AT0
Reference: 7ME6810-2DJ41-2AT0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors 3G/UMTS module for MAG8000 with antenna cable (5m) and analog cable (2.5m ) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ41-2AT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AT1
Reference: 7ME6810-2DJ41-2AT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and Analog Cable (2.5m ) Power: Built-in Internal Battery
Delivery: See availability
7ME6810-2DJ41-2AT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AT2
Reference: 7ME6810-2DJ41-2AT2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ41-2AT3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AT3
Reference: 7ME6810-2DJ41-2AT3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors 3G/UMTS module for MAG8000 with antenna cable (5m) and analog cable (2.5m) Power: 12/24V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2AT4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2AT4
Reference: 7ME6810-2DJ41-2AT4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors 3G/UMTS MAG8000 Module with Antenna Cable (5m) and Analog Cable (2.5m) Power: 115 - 230 V AC Power with Battery Backup and 3m (9.8 ft) Power Cable for External Connection (without Battery)
Delivery: See availability
7ME6810-2DJ41-2BA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BA0
Reference: 7ME6810-2DJ41-2BA0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: No additional communication module installed Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ41-2BA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BA1
Reference: 7ME6810-2DJ41-2BA1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: No additional communication module installed Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ41-2BA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BA2
Reference: 7ME6810-2DJ41-2BA2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: No additional communication module installed Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-2DJ41-2BA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BA3
Reference: 7ME6810-2DJ41-2BA3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pin connectors Transfer Interface: No additional communication module installed Power: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BA4
Reference: 7ME6810-2DJ41-2BA4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: No additional communication module installed Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BB0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BB0
Reference: 7ME6810-2DJ41-2BB0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pin connectors Transfer Interface: RS 485 standard with MODBUS RTU (with line termination) Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-2DJ41-2BB1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BB1
Reference: 7ME6810-2DJ41-2BB1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pin connectors Transfer Interface: RS 485 standard with MODBUS RTU (with line termination) Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ41-2BB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BB2
Reference: 7ME6810-2DJ41-2BB2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power: External battery with 1.5 m (4.9 ft) patch cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-2DJ41-2BB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BB3
Reference: 7ME6810-2DJ41-2BB3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: RS 485 standard with MODBUS RTU (with line termination) Power: 12/24V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BB4
Reference: 7ME6810-2DJ41-2BB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BC0
Reference: 7ME6810-2DJ41-2BC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate Basic Version, 5m (16.4 ft) Fixed Sensor Cable with IP68/NEMA6P 6-Pole Connectors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power: Internal Battery (Battery Not Included)
Delivery: See availability
7ME6810-2DJ41-2BC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BC1
Reference: 7ME6810-2DJ41-2BC1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: RS 232 serial port with MODBUS RTU Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ41-2BC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BC2
Reference: 7ME6810-2DJ41-2BC2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 232 serial port with MODBUS RTU Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-2DJ41-2BC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BC3
Reference: 7ME6810-2DJ41-2BC3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate base version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pin connectors Transfer Interface: RS 232 serial port with MODBUS RTU Power: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BC4 SIEMENS Water meter SITRANS FM MAG 8000 DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), D..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BC4
Reference: 7ME6810-2DJ41-2BC4
Catalog Number: -
Water meter SITRANS FM MAG 8000 DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Inter
Delivery: See availability
7ME6810-2DJ41-2BD0 SIEMENS Water meter SITRANS FM MAG 8000 DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), D..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BD0
Reference: 7ME6810-2DJ41-2BD0
Catalog Number: -
Water meter SITRANS FM MAG 8000 DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate Basic Version, 5m (16.4 ft) Fixed Sensor Cable with IP68/NEMA6P 6-Pole Connectors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: Internal Battery (Battery Not Included)
Delivery: See availability
7ME6810-2DJ41-2BD1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BD1
Reference: 7ME6810-2DJ41-2BD1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ41-2BD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BD2
Reference: 7ME6810-2DJ41-2BD2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-2DJ41-2BD3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BD3
Reference: 7ME6810-2DJ41-2BD3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: 12/24V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BD4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BD4
Reference: 7ME6810-2DJ41-2BD4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mounting: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BS0
Reference: 7ME6810-2DJ41-2BS0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mount: Separate Basic Version, 5m (16.4 ft) Fixed Cable on Sensor with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) Power: Internal Battery (Battery Not Included)
Delivery: See availability
7ME6810-2DJ41-2BS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BS1
Reference: 7ME6810-2DJ41-2BS1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) Power: Built-in internal battery
Delivery: See availability
7ME6810-2DJ41-2BS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BS2
Reference: 7ME6810-2DJ41-2BS2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) Power: External battery with 1.5 m (4.9 ft) patch cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-2DJ41-2BS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BS3
Reference: 7ME6810-2DJ41-2BS3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) Power: 12/24V AC/DC power with battery backup and 3m (9.8ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BS4
Reference: 7ME6810-2DJ41-2BS4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) Power: 115 - 230V AC power with battery backup and 3m (9.8ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BT0
Reference: 7ME6810-2DJ41-2BT0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate Basic Version, 5m (16.4 ft) Fixed Sensor Cable with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable (5m) and Analog Cable (2.5m) Power Supply: Internal Battery (Battery Not Included)
Delivery: See availability
7ME6810-2DJ41-2BT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BT1
Reference: 7ME6810-2DJ41-2BT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate Basic Version, 5m (16.4 ft) Fixed Sensor Cable with IP68/NEMA6P 6-Pole Connectors 3G/UMTS Module for MAG8000 with Antenna Cable(5m) and Analog Cable(2.5m) Power: Built-in Internal Battery
Delivery: See availability
7ME6810-2DJ41-2BT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BT2
Reference: 7ME6810-2DJ41-2BT2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate Basic Version, 5m (16.4 ft) Fixed Sensor Cable with IP68/NEMA6P 6-Pole Connectors 3G/UMTS MAG8000 Module with Antenna Cable(5m) and Analog Cable(2.5m) Power: External Battery with 1.5m (4.9ft) Connection Cable with IP68/NEMA 6P Connectors, Battery not included
Delivery: See availability
7ME6810-2DJ41-2BT3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BT3
Reference: 7ME6810-2DJ41-2BT3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed sensor cable with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: 12/24V AC/DC power supply with battery backup and 3m (9.8ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2BT4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2BT4
Reference: 7ME6810-2DJ41-2BT4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not includ
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate basic version, 5m (16.4 ft) fixed sensor cable with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power: 115 - 230V AC power with battery backup and 3m (9.8ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-2DJ41-2CA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-2DJ41-2CA0
Reference: 7ME6810-2DJ41-2CA0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) ANSI 16.5 Cl.150 EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 25 (1") DN25 / Qmx 17 m3/h(m3), 1 Inch / Qmx 74 GPM(G), DN25 / Qmx 0.408 Ml/d(Ml) Flange Standard and Nominal Pressure: ANSI B16.5: Class 150 EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type and Mount: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: No Additional Communication Module Installed Power: Internal Battery (Battery Not Included)
Delivery: See availability

products sitemap

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.