SIEMENS

Siemens is a global powerhouse in industrial automation and electrification, present in over 190 countries. Their product portfolio is the most extensive on the market, covering everything from power distribution and control to digital factory solutions. For the electrical engineer, Siemens offers a comprehensive range of industrial control comp...

7ME6810-3MC32-3DB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DB4
Reference: 7ME6810-3MC32-3DB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3DC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DC0
Reference: 7ME6810-3MC32-3DC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3DC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DC1
Reference: 7ME6810-3MC32-3DC1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3DC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DC2
Reference: 7ME6810-3MC32-3DC2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3DC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DC3
Reference: 7ME6810-3MC32-3DC3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3DC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DC4
Reference: 7ME6810-3MC32-3DC4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3DD0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DD0
Reference: 7ME6810-3MC32-3DD0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3DD1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DD1
Reference: 7ME6810-3MC32-3DD1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3DD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DD2
Reference: 7ME6810-3MC32-3DD2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3DD3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DD3
Reference: 7ME6810-3MC32-3DD3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3DD4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DD4
Reference: 7ME6810-3MC32-3DD4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3DS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DS0
Reference: 7ME6810-3MC32-3DS0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3DS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DS1
Reference: 7ME6810-3MC32-3DS1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3DS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DS2
Reference: 7ME6810-3MC32-3DS2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3DS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DS3
Reference: 7ME6810-3MC32-3DS3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3DS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DS4
Reference: 7ME6810-3MC32-3DS4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3DT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DT0
Reference: 7ME6810-3MC32-3DT0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3DT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DT1
Reference: 7ME6810-3MC32-3DT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3DT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DT2
Reference: 7ME6810-3MC32-3DT2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3DT3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DT3
Reference: 7ME6810-3MC32-3DT3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not includ
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3DT4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3DT4
Reference: 7ME6810-3MC32-3DT4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 20m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 20 m (65.6) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3EA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EA0
Reference: 7ME6810-3MC32-3EA0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: No additional communication module installed Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3EA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EA1
Reference: 7ME6810-3MC32-3EA1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: No additional communication module installed Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3EA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EA2
Reference: 7ME6810-3MC32-3EA2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface External battery pack 1.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: No additional communication module installed Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3EA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EA3
Reference: 7ME6810-3MC32-3EA3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 12-24 VACDC Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: No additional communication module installed Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3EA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EA4
Reference: 7ME6810-3MC32-3EA4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: No additional communication module installed Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3EB0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EB0
Reference: 7ME6810-3MC32-3EB0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3EB1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EB1
Reference: 7ME6810-3MC32-3EB1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3EB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EB2
Reference: 7ME6810-3MC32-3EB2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3EB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EB3
Reference: 7ME6810-3MC32-3EB3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3EB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EB4
Reference: 7ME6810-3MC32-3EB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3EC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EC0
Reference: 7ME6810-3MC32-3EC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pin connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3EC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EC1
Reference: 7ME6810-3MC32-3EC1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pin connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3EC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EC2
Reference: 7ME6810-3MC32-3EC2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pin connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3EC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EC3
Reference: 7ME6810-3MC32-3EC3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pin connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3EC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3EC4
Reference: 7ME6810-3MC32-3EC4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pin connectors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3ED0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ED0
Reference: 7ME6810-3MC32-3ED0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3ED1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ED1
Reference: 7ME6810-3MC32-3ED1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3ED2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ED2
Reference: 7ME6810-3MC32-3ED2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3ED3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ED3
Reference: 7ME6810-3MC32-3ED3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3ED4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ED4
Reference: 7ME6810-3MC32-3ED4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on the sensor with IP68/NEMA6P 6-pole connectors Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3ES0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ES0
Reference: 7ME6810-3MC32-3ES0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3ES1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ES1
Reference: 7ME6810-3MC32-3ES1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3ES2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ES2
Reference: 7ME6810-3MC32-3ES2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3ES3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ES3
Reference: 7ME6810-3MC32-3ES3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3ES4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ES4
Reference: 7ME6810-3MC32-3ES4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G / UMTS module for MAG8000 with antenna cable(5m) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3ET0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ET0
Reference: 7ME6810-3MC32-3ET0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3ET1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ET1
Reference: 7ME6810-3MC32-3ET1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3ET2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ET2
Reference: 7ME6810-3MC32-3ET2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (battery not include
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC32-3ET3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ET3
Reference: 7ME6810-3MC32-3ET3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not includ
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3ET4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3ET4
Reference: 7ME6810-3MC32-3ET4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3KA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KA0
Reference: 7ME6810-3MC32-3KA0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2 % of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: No additional communication module installed Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3KA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KA1
Reference: 7ME6810-3MC32-3KA1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: No additional communication module installed Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3KA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KA2
Reference: 7ME6810-3MC32-3KA2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type and Mount: Advanced Version Integrated into Sensor Transfer Interface: No Additional Communication Module Installed Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-3MC32-3KA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KA3
Reference: 7ME6810-3MC32-3KA3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type and Mount: Advanced Version Integrated in Sensor Transfer Interface: No additional communication modules installed Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3KA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KA4
Reference: 7ME6810-3MC32-3KA4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: No additional communication module installed Power supply: 115 - 230 V AC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3KB0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KB0
Reference: 7ME6810-3MC32-3KB0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3KB1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KB1
Reference: 7ME6810-3MC32-3KB1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3KB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KB2
Reference: 7ME6810-3MC32-3KB2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-3MC32-3KB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KB3
Reference: 7ME6810-3MC32-3KB3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type and Mount: Advanced Version Integrated in Sensor Transfer Interface: RS 485 Standard with MODBUS RTU (with Line Termination) Power Supply: 12/24 V AC/DC Power Supply with Battery Backup and 3m (9.8 ft) Power Cable for External Connection (without Battery)
Delivery: See availability
7ME6810-3MC32-3KB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KB4
Reference: 7ME6810-3MC32-3KB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional Specific Version: Australia (ML, l/h, 50 Hz) Transmitter Type and Mounting: Advanced Version Integrated into Sensor Transfer Interface: RS 485 Standard with MODBUS RTU (with Line Termination) Power Supply: 115 - 230 V AC Power with Battery Backup and 3m (9.8 ft) Power Cable for External Connection (without Battery)
Delivery: See availability
7ME6810-3MC32-3KC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KC0
Reference: 7ME6810-3MC32-3KC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 232 serial port with MODBUS RTU Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3KC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KC1
Reference: 7ME6810-3MC32-3KC1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 232 serial port with MODBUS RTU Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3KC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KC2
Reference: 7ME6810-3MC32-3KC2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 232 serial port with MODBUS RTU Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-3MC32-3KC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KC3
Reference: 7ME6810-3MC32-3KC3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 232 serial port with MODBUS RTU Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3KC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KC4
Reference: 7ME6810-3MC32-3KC4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Advanced version integrated into the sensor Transfer interface: RS 232 serial port with MODBUS RTU Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for external connection (without battery)
Delivery: See availability
7ME6810-3MC32-3KD0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KD0
Reference: 7ME6810-3MC32-3KD0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2 % of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated in the sensor Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC32-3KD1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KD1
Reference: 7ME6810-3MC32-3KD1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2 % of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated in the sensor Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: Built-in internal battery
Delivery: See availability
7ME6810-3MC32-3KD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC32-3KD2
Reference: 7ME6810-3MC32-3KD2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version compact Transmitter on sensor Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Amp. +/- 0.2% of measurement values +/- 2 mm/s DN 50 - 300 (2" - 12") Regional specific version: Australia (ML, l/h, 50 Hz) Type of transmitter and mounting: Advanced version integrated in the sensor Transfer interface: Transmitter interface module for ITRON 200WP Radio with Sensus Protocol Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-3MC41-1AB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-1AB4
Reference: 7ME6810-3MC41-1AB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: On sensors of integrated basic version Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC41-1AC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-1AC0
Reference: 7ME6810-3MC41-1AC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: On integrated basic version sensors Transfer interface: RS 232 serial port with MODBUS RTU Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC41-1ES0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-1ES0
Reference: 7ME6810-3MC41-1ES0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measurement value +/- 2 mm/s Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC41-1ES1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-1ES1
Reference: 7ME6810-3MC41-1ES1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Basic version remote 30m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measurement value +/- 2 mm/s Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate basic version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC41-1LT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-1LT1
Reference: 7ME6810-3MC41-1LT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) Internal 2 D-cell battery pack installed and disconne
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Advanced version separate, 5m (16.4 ft) fixed sensor cable with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) and analog cable (2.5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC41-1LT2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-1LT2
Reference: 7ME6810-3MC41-1LT2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs 3G/UMTS module for MAG8000 with remote antenna cable(5m) and analog input cable(2.5m) External battery pack 1.5m power cable with plugs (ba
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Advanced version separate, 5m (16.4 ft) fixed sensor cable with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable (5m) and analog cable (2.5m) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC41-2AA0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AA0
Reference: 7ME6810-3MC41-2AA0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors Transfer interface: No additional communication module installed Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC41-2AA1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AA1
Reference: 7ME6810-3MC41-2AA1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors Transfer interface: No additional communication module installed Power: Built-in internal battery
Delivery: See availability
7ME6810-3MC41-2AA2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AA2
Reference: 7ME6810-3MC41-2AA2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating and Hastelloy Electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type and Mounting: On Integrated Basic Version Sensors Transfer Interface: No additional communication module installed Power: External battery with 1.5 m (4.9 ft) patch cord with IP68/NEMA 6P connectors, Battery not included
Delivery: See availability
7ME6810-3MC41-2AA3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AA3
Reference: 7ME6810-3MC41-2AA3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300 Micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: No additional communication module installed Power: 12/24 V AC/DC power supply with battery backup and 3m (9.8 ft) power cord for the External connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AA4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AA4
Reference: 7ME6810-3MC41-2AA4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor No additional communication, Standard IrDA interface 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors Transfer interface: No additional communication module installed Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cable for the External connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AB0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AB0
Reference: 7ME6810-3MC41-2AB0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 485 Standard with MODBUS RTU (with Line Termination) Power Supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC41-2AB1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AB1
Reference: 7ME6810-3MC41-2AB1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 485 Standard with MODBUS RTU (with Line Termination) Power Supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC41-2AB2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AB2
Reference: 7ME6810-3MC41-2AB2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 485 Standard with MODBUS RTU (with Line Termination) Power Supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC41-2AB3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AB3
Reference: 7ME6810-3MC41-2AB3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 485 Standard with MODBUS RTU (with Line Termination) Power Supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AB4
Reference: 7ME6810-3MC41-2AB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 485 Standard with MODBUS RTU (with Line Termination) Power Supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AC0
Reference: 7ME6810-3MC41-2AC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power Supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC41-2AC1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AC1
Reference: 7ME6810-3MC41-2AC1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power Supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC41-2AC2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AC2
Reference: 7ME6810-3MC41-2AC2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power Supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC41-2AC3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AC3
Reference: 7ME6810-3MC41-2AC3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power Supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AC4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AC4
Reference: 7ME6810-3MC41-2AC4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Communication: Serial RS 232 interface module Modbus RTU 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: RS 232 Serial Port with MODBUS RTU Power Supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AD0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AD0
Reference: 7ME6810-3MC41-2AD0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC41-2AD1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AD1
Reference: 7ME6810-3MC41-2AD1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: Built-in internal battery
Delivery: See availability
7ME6810-3MC41-2AD2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AD2
Reference: 7ME6810-3MC41-2AD2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC41-2AD3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AD3
Reference: 7ME6810-3MC41-2AD3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AD4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AD4
Reference: 7ME6810-3MC41-2AD4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor Encoder interface with Sensus protocol 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM Coating & Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: USA (Gallons, GPM, 60 Hz) Transmitter Type & Mounting: On Integrated Basic Version Sensors Transfer Interface: Transmitter Interface Module for ITRON 200WP Radio with Sensus Protocol Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AS0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AS0
Reference: 7ME6810-3MC41-2AS0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors 3G/UMTS module for MAG8000 with antenna cable(5m) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-3MC41-2AS1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AS1
Reference: 7ME6810-3MC41-2AS1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) Internal 2 D-cell battery pack installed and disconnected inside meter
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors 3G/UMTS module for MAG8000 with antenna cable(5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-3MC41-2AS2 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AS2
Reference: 7ME6810-3MC41-2AS2
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) External battery pack 1.5m power cable with plugs (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors 3G/UMTS module for MAG8000 with antenna cable(5m) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included
Delivery: See availability
7ME6810-3MC41-2AS3 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AS3
Reference: 7ME6810-3MC41-2AS3
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 12-24 VACDC Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors 3G/UMTS module for MAG8000 with antenna cable(5m) Power supply: 12/24V AC/DC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-3MC41-2AS4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-3MC41-2AS4
Reference: 7ME6810-3MC41-2AS4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) EN 1092-1, PN 16, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version compact Transmitter on sensor 3G/UMTS module for MAG8000 with remote antenna cable(5m) 115-230VAC 50/60Hz Supply w. 3 m cable and battery backup (battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 80 (3") DN80 / Qmx 160 m3/h(m3), 3 Inch / Qmx 704 GPM(Gx100), DN80 / Qmx 3.84 Ml/d(Ml) Flange Standard and Nominal Pressure: EN 1092-1: PN 16 (DN 50...1200 (2"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: USA (gallons, GPM, 60 Hz) Transmitter type and mounting: On integrated basic version sensors 3G/UMTS module for MAG8000 with antenna cable(5m) Power supply: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability

products sitemap

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.