SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN200 / Qmx 997 m3/h(m3), 8 Inch / Qmx 4389 GPM(Gx100) , DN200 / Qmx 24 Ml/d(Ml) EN 1092-1, PN 10, Conforms to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Extended calibration 0,2% of rate +/- 2mm/s with certificate Region version: Europe Display: m3 based 50 Hz filter Advanced version remote 5m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU External battery pack 1.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal diameter: DN 200 (8") DN200 / Qmx 997 m3/h(m3), 8 Inch / Qmx 4389 GPM(Gx100) , DN200 / Qmx 24 Ml/d(Ml) Flange and pressure rating: EN 1092-1: PN 10 (DN 200...1200 (8"... 48")) EPDM Coating and Hastelloy Electrodes, 300micron Corrosion Resistant Coating Category C5 Calibration: Amp. +/- 0.2% of measured values +/- 2 mm/s DN 50 - 300 (2" - 12") Specific regional version: Europe (m3, m3/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, 5m (16.4 ft) fixed cable on sensor with IP68/NEMA6P 6-pole connectors Transfer interface: RS 485 standard with MODBUS RTU (with line termination) Power supply: External battery with 1.5 m (4.9 ft) connection cable with IP68/NEMA 6P connectors, battery not included