SIEMENS

Siemens is a global powerhouse in industrial automation and electrification, present in over 190 countries. Their product portfolio is the most extensive on the market, covering everything from power distribution and control to digital factory solutions. For the electrical engineer, Siemens offers a comprehensive range of industrial control comp...

7ME6810-7RD41-3PT0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-7RD41-3PT0
Reference: 7ME6810-7RD41-3PT0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN1000 / Qmax 28274 m3/h(m3), 40 Inch / Qmax 179 MGD(MG), DN1000 / Qmax 678.5 Ml/d(Ml) EN 1092-1, PN 16 non PED, Does not conform to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w.5m) Internal battery supply (Battery not included).
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal diameter: DN 1000 (40") DN1000 / Qmx 28274 m3/h(m3), 40 Inch / Qmx 179 MGD(MG), DN1000 / Qmx 678.5 Ml/d(Ml) Flange and nominal pressure standard: EN 1092-1: PN 16 does not comply with the Directiver for pressure appliances (DN 700...1200 (28"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: Internal battery (battery not included)
Delivery: See availability
7ME6810-7RD41-3PT1 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-7RD41-3PT1
Reference: 7ME6810-7RD41-3PT1
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN1000 / Qmax 28274 m3/h(m3), 40 Inch / Qmax 179 MGD(MG), DN1000 / Qmax 678.5 Ml/d(Ml) EN 1092-1, PN 16 non PED, Does not conform to PED EPDM liner and Hastelloy Electrodes, 300micron corrosion-resistant coating of category C5 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: Australia Display: ML based 50 Hz filter Advanced version remote 30m Mounted sensor cables w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal diameter: DN 1000 (40") DN1000 / Qmx 28274 m3/h(m3), 40 Inch / Qmx 179 MGD(MG), DN1000 / Qmx 678.5 Ml/d(Ml) Flange and nominal pressure standard: EN 1092-1: PN 16 does not comply with the Directiver for pressure appliances (DN 700...1200 (28"... 48")) EPDM coating and Hastelloy electrodes, 300micron corrosion resistant coating category C5 Calibration: Standard +/- 0.4% of measured value +/- 2 mm/s Regional specific version: Australia (ML, l/h, 50 Hz) Transmitter type and mounting: Separate Advanced version, fixed cable Do - 30 m (98.4) on sensor with IP68/NEMA6P 6-pole connectors 3G/UMTS module for MAG8000 with antenna cable(5m) and analog cable(2.5m) Power supply: Built-in internal battery
Delivery: See availability
7ME6810-7RL31-2CB4 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-7RL31-2CB4
Reference: 7ME6810-7RL31-2CB4
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN1000 / Qmax 28274 m3/h(m3), 40 Inch / Qmax 179 MGD(MG), DN1000 / Qmax 678.5 Ml/d(Ml) AWWA C-207 Cl.D EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Communication: Serial RS 485 interface module Modbus RTU 115-230VAC 50/60Hz Supply w.
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 1000 (40") DN1000 / Qmx 28274 m3/h(m3), 40 Inch / Qmx 179 MGD(MG), DN1000 / Qmx 678.5 Ml/d(Ml) Flange Standard and Nominal Pressure: AWWA C-207: Class D (28"... 48") EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: RS 485 standard with MODBUS RTU (with line termination) Power: 115 - 230 V AC power with battery backup and 3m (9.8 ft) power cord for external connection (without battery)
Delivery: See availability
7ME6810-7RL31-2CC0 SIEMENS SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter..

SIEMENS

Manufacturer Code: 7ME6810-7RL31-2CC0
Reference: 7ME6810-7RL31-2CC0
Catalog Number: -
SITRANS FM MAG 8000 Battery-operated electromagnetic flowmeter, flanged, diameter DN 25 to DN 1200 (1" to 48"). Suitable for volume flow measurement of liquids (conductive) and water applications within abstraction, distribution network, revenue metering and irrigation. . DN1000 / Qmax 28274 m3/h(m3), 40 Inch / Qmax 179 MGD(MG), DN1000 / Qmax 678.5 Ml/d(Ml) AWWA C-207 Cl.D EPDM liner and Hastelloy Electrodes, corrosion-resistant coating of category C4 Standard calibration w. max. 0,4% of rate +/- 2mm/s with certificate Region version: USA Display: Gallon based 60 Hz filter Basic version remote 10m Mounted sensor cables w. plugs Communication: Serial RS 232 interface module Modbus RTU Internal battery supply (Battery not included)
SITRANS FM MAG 8000 Battery-operated electromagnetic flow sensor, with flange, diameter from DN 25 to DN 1200 (from 1" to 48"). Suitable for continuous measurement of volumetric flow of liquids (conductors) for water applications in the collection, distribution, billing and irrigation sectors. . Nominal Diameter: DN 1000 (40") DN1000 / Qmx 28274 m3/h(m3), 40 Inch / Qmx 179 MGD(MG), DN1000 / Qmx 678.5 Ml/d(Ml) Flange Standard and Nominal Pressure: AWWA C-207: Class D (28"... 48") EPDM Coating & Hastelloy Electrodes, Corrosion Resistant Coating Category C4 Calibration: Standard +/- 0.4% of Measured Value +/- 2 mm/s Regional Specific Version: US (gallons, GPM, 60 Hz) Transmitter Type & Mounting: Separate Basic Version, Fixed Cable Do - 10 m (32.8) on Sensor with IP68/NEMA6P 6-Pole Connectors Transfer Interface: RS 232 serial port with MODBUS RTU Power: Internal battery (battery not included)
Delivery: See availability

products sitemap

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.