Surge protection plug type 2 with high-capacity varistor for VAL-MS base element, thermal monitoring, visual fault warning. Design: 60 V AC

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+37,77 €
20+37,06 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height52.4 mm
Width17.5 mm
Depth55.3 mm
Horizontal pitch1 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g
Vibration (operation)5g

General

Standards/specificationsIEC 61643-11 2011
EN 61643-11 2012
IEC test classificationII
T2
EN typeT2
SPD designVoltage-limiting type
Mode of protectionL-PEN
Mounting typeOn base element
Colorblack
Housing materialPA 6.6
Pollution degree2
Flammability rating according to UL 94V-0
TypeMale
Number of positions1
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.10
Surge protection fault messageoptical

Protective circuit

Nominal voltage UN60 V AC (TN)
60 V DC
-48 V DC (RRH)
Nominal frequency fN60 Hz (50 Hz)
Maximum continuous voltage UC75 V AC
Residual current IPE≤ 0.45 mA
Standby power consumption PC≤ 35 mVA
Nominal discharge current In (8/20) µs15 kA
Maximum discharge current Imax (8/20) µs40 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 0.55 kV
Residual voltage Ures≤ 0.55 kV (at In)
≤ 0.425 kV (at 10 kA)
≤ 0.325 kV (at 5 kA)
≤ 0.275 kV (at 3 kA)
TOV behavior at UT100 V AC (5 s / withstand mode)
Response time tA≤ 25 ns
Max. backup fuse with branch wiring125 A AC (gG)
50 A DC (gG)

Connection data

Connection methodVALVETRAB plug-in system

UL specifications

SPD Type4 (for Type 2 applications)
Maximum continuous operating voltage MCOV (L-N)75 V AC
Maximum continuous operating voltage MCOV (L+) - (L-)100 V DC
Maximum continuous operating voltage MCOV (L+/L-) - G100 V DC
Nom. voltage60 V AC
Nominal voltage60 V DC
Mode of protectionL-N
(L+) - (L-)
(L+/L-) - G
Power distribution system1
Nominal frequency50/60 Hz
Voltage protection rating VPR (L-N)0.5 kV
Voltage protection rating VPR (L+) - (L-)0.33 kV
Voltage protection rating VPR (L+/L-) -G0.33 kV
Nominal discharge current In (L-N)10 kA
Nominal discharge current In (L+) - (L-)10 kA
Nominal discharge current In (L+/L-) - G10 kA