Safety-oriented decentral relay output module, IP20 degree of protection, for the INTERBUS-Safety and the PROFIsafe system. This module has four safe digital relay outputs, each having two contacts.
Safety-oriented, IP20-rated, decentralised relay output module for SafetyBridge, INTERBUS-Safety and PROFIsafe systems. The module has 4 safe relay outputs with two contacts each.
PLC's > Fieldbus, decentr. periphery - digital I/O module
Safety
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
The safety module is an output module from the Inline product range, designed for use in an INTERBUS-Safety or PROFIsafe system. The safety module can be used as part of an Inline station at any point within an INTERBUS-Safety or PROFIsafe Inline system.
The transmission speed of the safety module can be set to 500 kbaud or 2 Mbaud using a switch. Only one transmission speed must be used uniformly within a station. The module has four safe digital relay outputs, each with two relay contacts. The outputs can be parameterized according to the application and enable the integration of actuators in the safe INTERBUS system (INTERBUS-Safety) and in the PROFIsafe system.
The safety-related segment circuit can be switched on or off using suitable wiring.
When the output is switched off, the supply to the subsequent modules is disconnected safely.
The module also has two clock outputs with assigned alarm inputs for monitoring external contact extensions.
Depending on the installation and parameterization, in these systems the safety module can achieve the following safety integrity:
– Up to category 4 according to standard EN 954-1
– Up to SIL 3 according to standards EN 61508 and EN 62061
– Up to PL e according to standard EN ISO 13849-1
| Width | 73.2 mm |
|---|---|
| Height | 119.8 mm |
| Depth | 71.5 mm |
| Note on dimensions | Housing dimensions |
| Ambient temperature (operation) | -25 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Permissible humidity (operation) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Permissible humidity (storage/transport) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above mean sea level) |
| Degree of protection | IP20 |
| Fieldbus system | INTERBUS |
|---|---|
| Designation | Inline local bus |
| Connection method | Inline data jumper |
| Transmission speed | 500 kBit/ / 2 MBit/s (can be switched) |
| Output name | Relay output |
|---|---|
| Connection method | Spring-cage connection |
| 2-wire | |
| Number of outputs | 4 (Safety relays) |
| Output voltage | 24 V DC (US- 1 V) |
| Nominal output voltage | 24 V DC (Inline connector) |
| Output current | max. 4 A (Inline connector, pro contact, observe derating) |
| max. 6 A (COMBICON connector, pro contact, observe derating) | |
| Maximum output current per channel | 4 A |
| Supply voltage | 24 V DC (via voltage jumper) |
|---|---|
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Communications power UL | 7.5 V (via voltage jumper) |
| Current consumption | max. 360 mA (from the local bus) |
| Net weight | 386 g |
|---|---|
| Note on weight specifications | with connectors |
| Mounting type | DIN rail |
| Category according to EN 13849-1 | 4 |
| Communications power UL | 7.5 V DC (see safety data) |
|---|---|
| Current consumption from UL | max. 360 mA |
| Main circuit supply UM | 24 V DC |
| Supply voltage range UM | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption from UM | typ. 30 mA (all outputs set including actuator current) |
| max. 0.03 A | |
| Segment supply voltage US | 24 V |
| Feature Name | Feature Value |
|---|---|
| Supply voltage DC (EF007534) | 19.2 V |
| Voltage type (supply voltage) (EF002991) | DC |
| Number of digital inputs (EF001992) | 0 |
| Number of digital outputs (EF001993) | 0 |
| Digital inputs configurable (EF008516) | No |
| Digital outputs configurable (EF008520) | No |
| Type of voltage (input voltage) (EF003033) | DC |
| Type of digital output (EF003601) | None |
| Short-circuit protection, outputs available (EF003203) | No |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of HW-interfaces USB (EF003025) | 0 |
| Number of HW-interfaces other (EF003027) | 2 |
| With optical interface (EF003028) | No |
| Supporting protocol for EtherCAT (EF017564) | No |
| Supporting protocol for TCP/IP (EF003050) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for INTERBUS (EF003054) | Yes |
| Supporting protocol for ASI (EF003051) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Supporting protocol for other bus systems (EF003062) | No |
| Radio standard Bluetooth (EF007178) | No |
| Radio standard WLAN 802.11 (EF007179) | No |
| Radio standard GPRS (EF008523) | No |
| Radio standard GSM (EF008524) | No |
| Radio standard UMTS (EF008525) | No |
| IO link master (EF007298) | No |
| System accessory (EF004118) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Time delay at signal change (EF002382) | 0 ms |
| Fieldbus connection over separate bus coupler possible (EF004002) | Yes |
| Suitable for rail mounting (EF003972) | Yes |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Rack-assembly possible (EF007018) | No |
| Suitable for safety functions (EF001597) | Yes |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Explosion safety category for gas (EF003997) | None |
| Explosion safety category for dust (EF003998) | None |
| Width (EF000008) | 72.9 mm |
| Height (EF000040) | 120 mm |
| Depth (EF000049) | 71.03 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE AUTOMATION PHOENIX EN.pdf | 35 Mbytes |
|
| PHOENIX CONTACT-2985864-IB IL 24 PSDOR 4-PAC | 110 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.