ANUNCIAR
NX-TS2202 NX020057G NXTS2202 OMRON Unit NX 2 Inputs: RTD 0.01 ° C 10 ms View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NX-TS2202 NX020057G NXTS2202 OMRON Unit NX 2 Inputs: RTD 0.01 ° C 10 ms

NX-TS2202

NX020057G

NXTS2202

OMRON

Unit NX - 2 Inputs: RTD 0.01 ° C 10 ms

2 Temperature Sensor Inputs, Pt100 (3-wire), resolution 0.01°C, 10 ms/Unit, screwless push-in connector, 12 mm wide

More details


PLC's > Fieldbus, decentr. periphery - analogue I/O module

Integrated Automation > Machine I/O NX-series

Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Total: $789.53
Unit price: $789.53
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



I/O systemNX I/O BusType of moduleAnalog I/ONumber of analog inputs2Temperature input typePt100Linear analog input typeNoneResolution of the analog inputs17 BitInput circuit typeSingle-endedNumber of analog outputs0Linear analog output typeNoneResolution of the analog outputs0 BitConversion time10 ms/unitSignal processingFree runningIO-Link masterI/O connection typePush-inNumber of I/O connectors1Detachable I/O connectorSuitable for safety functionsSIL according to IEC 61508NoneDegree of protection (IP)IP20Product Height (unpacked)100 mmProduct Width (unpacked)12 mmProduct Depth (unpacked)80 mmProduct Weight (unpacked)70 g
ETIM for 380136 PLC's (EC001596)
Feature Name Feature Value
Degree of protection (NEMA) (EF011959) Other
Degree of protection (IP) (EF005474) IP20
Performance level according to EN ISO 13849-1 (EF007399) Level a
SIL according to IEC 61508 (EF009889) None
Voltage type (supply voltage) (EF002991) DC
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Type of electric connection (EF003961) Spring clamp connection
Output, current (EF003212) No
Radio standard UMTS (EF008525) No
Input, voltage (EF003205) No
Input, thermocouple (EF003208) No
Supporting protocol for EtherCAT (EF017564) Yes
Analogue inputs configurable (EF008518) Yes
Appendant operation agent (Ex ib) (EF004142) No
Input, current (EF003204) No
Supporting protocol for other bus systems (EF003062) Yes
Analogue outputs configurable (EF008519) No
Supporting protocol for SERCOS (EF006657) No
IO link master (EF007298) No
Rack-assembly possible (EF007018) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for LON (EF003017) No
Input, resistance thermometer (EF003207) Yes
Supporting protocol for SUCONET (EF003060) No
Input signal, configurable (EF003209) Yes
Output signal configurable (EF003214) No
Supporting protocol for EtherNet/IP (EF007521) Yes
Radio standard GSM (EF008524) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for DeviceNet (EF003059) No
Suitable for rail mounting (EF003972) Yes
Supporting protocol for INTERBUS-Safety (EF006662) No
Input, resistor (EF003206) No
Supporting protocol for PROFIsafe (EF007526) No
System accessory (EF004118) No
Certified for UL hazardous location class III (EF017627) No
Supporting protocol for PROFIBUS (EF003052) No
Radio standard GPRS (EF008523) No
Certified for UL hazardous location class II (EF017625) No
Certified for UL hazardous location class I (EF017622) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for TCP/IP (EF003050) No
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for SafetyBUS p (EF007527) No
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Appendant operation agent (Ex ia) (EF004141) No
Supporting protocol for Modbus (EF003057) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Supporting protocol for PROFINET CBA (EF007524) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Radio standard Bluetooth (EF007178) No
Suitable for safety functions (EF001597) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Radio standard WLAN 802.11 (EF007179) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Output, voltage (EF003213) No
Certified for UL hazardous location division 2 (EF017629) No
Certified for UL hazardous location division 1 (EF017628) No
Certified for UL hazardous location group D (propane) (EF017636) No
Supporting protocol for ASI (EF003051) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
Number of HW-interfaces other (EF003027) 1
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces USB (EF003025) 0
Width (EF000008) 12 mm
Number of HW-interfaces serial TTY (EF003024) 0
Depth (EF000049) 80 mm
Number of HW-interfaces wireless (EF006933) 0
Number of analogue inputs (EF001994) 2
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of analogue outputs (EF001995) 0
Resolution of the analogue inputs (EF003575) 17 Bit
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Height (EF000040) 100 mm
Supply voltage DC (EF007534) 20.4 V

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.