Product successfully added to your shopping cart
NX-EC0112
NX020101H
NXEC0112
OMRON
1
Unit NX - 1 Input of Encoder NPN Incremental
1 x Incremental Encoder NPN Input, Phases A and B: Single-phase 500 kHz (phase difference pulse Input x4: 125 kHz), Phase Z: 125 kHz, screwless push-i
PLC's > Fieldbus, decentr. periphery - function-/technology module
Integrated Automation > Machine I/O NX-series
Brand new product in its original packaging covered by the warranties and certifications provided by OMRON
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Feature Name | Feature Value |
|---|---|
| Degree of protection (NEMA) (EF011959) | Other |
| Degree of protection (IP) (EF005474) | IP20 |
| Performance level according to EN ISO 13849-1 (EF007399) | Level a |
| SIL according to IEC 61508 (EF009889) | None |
| Voltage type (supply voltage) (EF002991) | DC |
| Explosion safety category for gas (EF003997) | None |
| Explosion safety category for dust (EF003998) | None |
| Function block access control (EF007213) | No |
| Radio standard UMTS (EF008525) | No |
| Function block affirm push button (EF007214) | No |
| Suitable for counting (EF003248) | Yes |
| Supporting protocol for EtherCAT (EF017564) | Yes |
| Suitable for weighing (EF003249) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Suitable for SSI (EF003254) | No |
| Supporting protocol for other bus systems (EF003062) | Yes |
| Suitable for CNC (EF003256) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| IO link master (EF007298) | No |
| Suitable for detection absolute value (EF003259) | No |
| Rack-assembly possible (EF007018) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for LON (EF003017) | No |
| Suitable for path controller (EF003262) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for EtherNet/IP (EF007521) | Yes |
| Radio standard GSM (EF008524) | No |
| Function block contactless working protection installation (EF007209) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Suitable for multi-axis control (EF003265) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Function block restart blockage (EF007212) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Suitable for rail mounting (EF003972) | Yes |
| Suitable for temperature control (EF008344) | No |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| System accessory (EF004118) | Yes |
| Certified for UL hazardous location class III (EF017627) | No |
| Suitable for welding control (EF003251) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Radio standard GPRS (EF008523) | No |
| Certified for UL hazardous location class II (EF017625) | No |
| Function block 2-hand switching (EF007215) | No |
| Suitable for multi-axis positioning (EF003267) | No |
| Suitable for flux measurement (EF003261) | No |
| Certified for UL hazardous location class I (EF017622) | No |
| Suitable for incremental data detection (EF003258) | Yes |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for TCP/IP (EF003050) | No |
| Suitable for cam controller (EF003263) | No |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Frequency measurement (EF000599) | Yes |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Fieldbus connection over separate bus coupler possible (EF004002) | Yes |
| Contactor control function block (EF007467) | No |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Suitable for NC (EF003253) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Suitable for flying saw (EF003264) | No |
| Certified for UL hazardous location group G (non-conductive dusts) (EF017639) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) | No |
| Radio standard Bluetooth (EF007178) | No |
| Suitable for safety functions (EF001597) | No |
| Suitable for single-axis controller (EF003266) | No |
| Function block emergency stop (EF007211) | No |
| Certified for UL hazardous location group E (metal dusts) (EF017637) | No |
| With optical interface (EF003028) | No |
| Function block operating mode selection (EF007210) | No |
| Function block automatic reset (EF007208) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Radio standard WLAN 802.11 (EF007179) | No |
| Certified for UL hazardous location group A (acetylene) (EF017632) | No |
| Certified for UL hazardous location division 2 (EF017629) | No |
| Certified for UL hazardous location division 1 (EF017628) | No |
| Suitable for flux controller (EF003260) | No |
| Certified for UL hazardous location group D (propane) (EF017636) | No |
| Suitable for single-axis positioning (EF003268) | No |
| Supporting protocol for ASI (EF003051) | No |
| Certified for UL hazardous location group C (ethylene) (EF017635) | No |
| Suitable for pressure control (EF003252) | No |
| Suitable for electronic positioning (EF003255) | No |
| Certified for UL hazardous location group B (hydrogen) (EF017633) | No |
| Number of HW-interfaces other (EF003027) | 1 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of HW-interfaces USB (EF003025) | 0 |
| Width (EF000008) | 12 mm |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Depth (EF000049) | 71 mm |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Height (EF000040) | 100 mm |
| Number of functions (EF003244) | 1 |
| Supply voltage DC (EF007534) | 20.4 V |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG OMRON 2024 EN.pdf | 25 Mbytes |
|
| NX-EC0112 NXEC0112 NX020101H EN_NX-EC0112.pdf | 7 Mbytes |
![]() |
| NX-EC0112 NXEC0112 NX020101H panel_building_brochure_en.pdf | 3 Mbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.