INTERFACE PROTECTION UNIT COMPLIANT WITH ENA (ENERGY NETWORK ASSOCIATION) G59/G99 FOR THREE-PHASE SYSTEM, WITH OR WITHOUT NEUTRAL, LOW AND HIGH VOLTAGE, MINIMUM AND MAXIMUM VOLTAGE AND FREQUENCY DUAL THRESHOLD PROTECTION, ROCOF AND VECTOR SHIFT, 230VAC - 400VAC
Protection relays - LOVATO ELECTRIC
* Brand new product in its original packaging covered by the warranties and certifications provided by LOVATO ELECTRIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Order code | PMVF70 |
Weight [g] | 420 |
Qty. per package | 1 |
Multiple qty. of packs per order | 1 |
Package dimensions [mm] | 153X117X092 |
Volume [cm³] | 1646 |
Bar code [EAN13] | 8013975231937 |
HS Code | 85364900 |
Product designation | Interface protection system units compliant with G59 (ENA) technical guide | |||
Product type designation | PMVF70 | |||
General characteristics | ||||
Description | System with or without neutral in low or high voltage. Dual threshold minimum and maximum voltage and frequency protection. ROCOF and Vector shift | |||
Type of system | Single and three phase | |||
Power supply | ||||
Operating voltage range | 85…264VAC / 93.5…300VDC | |||
Rated frequency | Hz | 45…55 | ||
Control circut | ||||
Rated current (Ie) | A | 1 or 5 in AC programmable | ||
Auxiliary supply | ||||
Rated auxiliary supply voltage Us | ||||
AC | ||||
min | VAC | 100 | ||
Max | VAC | 240 | ||
DC | ||||
min | VDC | 110 | ||
Max | VDC | 250 | ||
Power consumption | ||||
AC (Max) | ||||
VA | 4.6VA al 110VAC; 12.5VA at 230VAC | |||
DC (Max) | ||||
VA | 23mA at 110VDC; 11mA at 250VDC | |||
Power dissipation | ||||
AC (Max) | ||||
W | 2.5W at 110VAC;2.7W at 230VAC | |||
DC (Max) | ||||
W | 2.3W at 110VDC; 2.5W at 250VDC | |||
Immunity time for microbreakings | ms | ≤50ms at 100VDC; ≤200ms at 240VDC | ||
Voltage inputs | ||||
Maximum rated operational voltage | 400VAC L-L;230VAC L-N 50Hz | |||
Measurement range | V | 20…480VAC L-L; 10…276VAC L-N | ||
Frequency range | Hz | 45…55 | ||
Current inputs | ||||
Measurement range | For 1A scale: 0.01…1.2A; for 5A scale: 0.01…6A | |||
Measurement method | RMS | |||
Overload peak | A | 50A for 1 second | ||
Burden per phase | W | ≤0.6W | ||
Relay outputs | ||||
Number of relays | Nr. | 2 | ||
Contact arrangement | 1 changeover contact/SPDT each | |||
Rated operational voltage AC (IEC) | VAC | 250 | ||
UL/CSA and IEC/EN 60947-5-1 designation | For NO contact: 5A 250VAC AC1/C300; 5A 30VDCFor NC contact: 2A 250VAC AC1/C300; 2A 30VDC | |||
Digital inputs | ||||
Number and type of inputs | 4 negative (PNP) | |||
Input voltage | 12VDC isolated | |||
Input current | mA | 7 | ||
Connections | ||||
Terminals type | Screw - removable | |||
Tightening torque for terminals | ||||
max | Nm | 0.8 | ||
max | Ibin | 4.5 | ||
Conductor cross section | ||||
AWG/Kcmil | ||||
min | AWG | 24 | ||
Max | AWG | 12 | ||
IEC | ||||
min | mm² | 0.2 | ||
Max | mm² | 4 | ||
Housing | ||||
Execution (n° of modules) | 6 | |||
Material | Polyamide | |||
Mounting | Modular 6U | |||
IEC degree of protection | IP40 on front; IP20 at terminals | |||
Dimensions (W x H x D) | mm | 108 x 105.4 x 63 | ||
Weight | g | 470 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE LOVATO EN.pdf | 178 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.