M1P0181012060 LOVATO DIRECT-ON-LINE-STARTER, ENCLOSED WITHOUT THERMAL OVERLOAD RELAY, WITH START AND STOP/RE.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

M1P0181012060 LOVATO DIRECT-ON-LINE-STARTER, ENCLOSED WITHOUT THERMAL OVERLOAD RELAY, WITH START AND STOP/RE..

M1P0181012060

LOVATO ELECTRIC

DIRECT-ON-LINE-STARTER, ENCLOSED WITHOUT THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BF09/BF18 CONTACTOR, 18A MAX. (≤440V), IP65. CONTACTOR COIL VOLTAGE 120VAC 60HZ

DOL STARTER M1P 120/60 18A W/O RELAY

Direct-on-line-starter, enclosed without thermal overload relay, with START and STOP/RESET buttons, with BF09/BF18 contactor, 18A max (≤440V), IP65. Contactor coil voltage 120VAC 60Hz

DIRECT STARTER, WITHOUT THERMAL RELAY IN INSULATED CASE, WITH START AND STOP/RESET BUTTONS, WITH BF09/BF18 CONTACTOR, 18A MAX. (?440V), IP65. CONTACTOR COIL VOLTAGE 120VAC 60HZ

More details


Low-voltage industrial components > Motor starter/Motor starter combination

Electromechanical starters - LOVATO ELECTRIC

Brand new product in its original packaging covered by the warranties and certifications provided by LOVATO ELECTRIC

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



M1P0181012060

Direct-on-line-starter, enclosed without thermal overload relay, with START and STOP/RESET buttons, with BF09/BF18 contactor, 18A max (≤440V), IP65. Contactor coil voltage 120VAC 60Hz

Technical specifications

Type of product:
Direct-on-line-starters
UL/CSA horsepower ratings 480V [HP]:
10
Type:
Enclosed without thermal overload relay
Type of coil:
AC coil
Type of pushbutton:
With Start-Stop/Reset buttons
Contactor coil voltage:
120VAC 60HZ
Order codeM1P0181012060
Weight [g]896
Qty. per package1
Multiple qty. of packs per order1
Package dimensions [mm]206X092X170
Volume [cm³]3221.84
Bar code [EAN13]8013975158708
HS Code85371098

154.28 £


ETIM for M1P0181012060 Low-voltage industrial controls and switchgear (EC001037)
Feature Name Feature Value
Degree of protection (NEMA) (EF011959) 4X
Type of motor starter (EF009598) Direct starter
Voltage type for actuating (EF008242) AC
Type of electrical connection for auxiliary- and control current circuit (EF006979) Screw connection
Type of electrical connection of main circuit (EF006819) Screw connection
Release class (EF006668) CLASS 10 A
Degree of protection (IP) (EF005474) IP65
Rated control supply voltage AC 60 Hz (EF003979) 120 V
Temperature compensated overload protection (EF009604) Yes
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
With fuse (EF006693) No
With short-circuit release (EF006691) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for SERCOS (EF006657) No
Suitable for rail mounting (EF003972) No
External reset possible (EF003426) Yes
Supporting protocol for other bus systems (EF003062) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for LON (EF003017) No
Suitable for emergency stop (EF001433) No
With transformer (EF000278) No
Rated conditional short-circuit current, type 2, 230 V (EF009606) 50000 A
Rated conditional short-circuit current, type 2, 400 V (EF009605) 50000 A
Ambient temperature, upper operating limit (EF009603) 60 °C
Rated operation current at AC-3, 400 V (EF009602) 18 A
Rated operation power at AC-3, 230 V, 3-phase (EF009599) 4 kW
Number of indicator lights (EF001965) 0
Rated operation current Ie (EF001443) 18 A
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Rated operation power at AC-3, 400 V (EF001364) 7.5 kW
Depth (EF000049) 155 mm
Height (EF000040) 202 mm
Width (EF000008) 88 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.