LOVATO ELECTRIC M0P00912230602V3 M0P00912230602V3 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

M0P00912230602V3 LOVATO DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RE..

Reference: M0P00912230602V3

Manufacturer: LOVATO ELECTRIC

Description:

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 2.3A MAX (0.55…0.75KW A 400V), IP65. CONTACTOR COIL VOLTAGE 230VAC 60HZ
DOL STARTER
Direct-on-line-starter, 1.4...2.3A (0.55...0.75kW at 400V), IP65, contactor coil voltage 230VAC 60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

Categories:

  • Low-voltage industrial components > Motor starter/Motor starter combination
  • LOVATO ELECTRIC > Electromechanical starters - LOVATO ELECTRIC

Brand new product in its original packaging covered by the warranties and certifications provided by LOVATO ELECTRIC

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

MORE INFO

M0P00912230602V3

Direct-on-line-starter, 1.4...2.3A (0.55...0.75kW at 400V), IP65, contactor coil voltage 230VAC 60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

Technical specifications

Type of product:
Direct-on-line-starters
IEC operating current and power Ie (AC3) 400V [A/Kw]:
2.3A / 0.75kW
UL/CSA horsepower ratings 480V [HP]:
1
Type:
Enclosed with thermal overload relay
Type of coil:
AC coil
Type of pushbutton:
With Start-Stop/Reset buttons
Contactor coil voltage:
230VAC 60HZ
Order codeM0P00912230602V3
Weight [g]780
Qty. per package1
Multiple qty. of packs per order1
Package dimensions [mm]187X092X160
Volume [cm³]2752.64
Bar code [EAN13]8013975157763
HS Code85371098

ETIM for M0P00912230602V3 Low-voltage industrial controls and switchgear (EC001037)

Feature nameDegree of protection (NEMA) (EF011959)
Feature value4X
Feature nameType of motor starter (EF009598)
Feature valueDirect starter
Feature nameVoltage type for actuating (EF008242)
Feature valueAC
Feature nameType of electrical connection for auxiliary- and control current circuit (EF006979)
Feature valueScrew connection
Feature nameType of electrical connection of main circuit (EF006819)
Feature valueScrew connection
Feature nameRelease class (EF006668)
Feature valueCLASS 10 A
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP65
Feature nameRated control supply voltage AC 60 Hz (EF003979)
Feature value230 V
Feature nameOverload release current setting (EF002336)
Feature value1.4 A
Feature nameTemperature compensated overload protection (EF009604)
Feature valueYes
Feature nameSupporting protocol for SafetyBUS p (EF007527)
Feature valueNo
Feature nameSupporting protocol for PROFIsafe (EF007526)
Feature valueNo
Feature nameSupporting protocol for PROFINET IO (EF007525)
Feature valueNo
Feature nameSupporting protocol for PROFINET CBA (EF007524)
Feature valueNo
Feature nameSupporting protocol for Foundation Fieldbus (EF007522)
Feature valueNo
Feature nameSupporting protocol for EtherNet/IP (EF007521)
Feature valueNo
Feature nameSupporting protocol for DeviceNet Safety (EF007520)
Feature valueNo
Feature nameSupporting protocol for AS-Interface Safety at Work (EF007519)
Feature valueNo
Feature nameWith fuse (EF006693)
Feature valueNo
Feature nameWith short-circuit release (EF006691)
Feature valueNo
Feature nameSupporting protocol for INTERBUS-Safety (EF006662)
Feature valueNo
Feature nameSupporting protocol for SERCOS (EF006657)
Feature valueNo
Feature nameSuitable for rail mounting (EF003972)
Feature valueNo
Feature nameExternal reset possible (EF003426)
Feature valueYes
Feature nameSupporting protocol for other bus systems (EF003062)
Feature valueNo
Feature nameSupporting protocol for SUCONET (EF003060)
Feature valueNo
Feature nameSupporting protocol for DeviceNet (EF003059)
Feature valueNo
Feature nameSupporting protocol for Data-Highway (EF003058)
Feature valueNo
Feature nameSupporting protocol for Modbus (EF003057)
Feature valueNo
Feature nameSupporting protocol for INTERBUS (EF003054)
Feature valueNo
Feature nameSupporting protocol for CAN (EF003053)
Feature valueNo
Feature nameSupporting protocol for PROFIBUS (EF003052)
Feature valueNo
Feature nameSupporting protocol for ASI (EF003051)
Feature valueNo
Feature nameSupporting protocol for TCP/IP (EF003050)
Feature valueNo
Feature nameSupporting protocol for LON (EF003017)
Feature valueNo
Feature nameSuitable for emergency stop (EF001433)
Feature valueNo
Feature nameWith transformer (EF000278)
Feature valueNo
Feature nameRated conditional short-circuit current, type 2, 230 V (EF009606)
Feature value50000 A
Feature nameRated conditional short-circuit current, type 2, 400 V (EF009605)
Feature value50000 A
Feature nameAmbient temperature, upper operating limit (EF009603)
Feature value60 °C
Feature nameRated operation current at AC-3, 400 V (EF009602)
Feature value2.3 A
Feature nameRated operation power at AC-3, 230 V, 3-phase (EF009599)
Feature value2.2 kW
Feature nameNumber of indicator lights (EF001965)
Feature value0
Feature nameRated operation current Ie (EF001443)
Feature value2.3 A
Feature nameNumber of auxiliary contacts as normally closed contact (EF001377)
Feature value0
Feature nameNumber of auxiliary contacts as normally open contact (EF001376)
Feature value0
Feature nameRated operation power at AC-3, 400 V (EF001364)
Feature value0.75 kW
Feature nameDepth (EF000049)
Feature value140 mm
Feature nameHeight (EF000040)
Feature value184 mm
Feature nameWidth (EF000008)
Feature value88 mm

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.