SIEMENS

Siemens is a global powerhouse in industrial automation and electrification, present in over 190 countries. Their product portfolio is the most extensive on the market, covering everything from power distribution and control to digital factory solutions. For the electrical engineer, Siemens offers a comprehensive range of industrial control comp...

7ML5440-1AB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1AB00-0AA1
Reference: 7ML5440-1AB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1AB00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1AB00-0AA2
Reference: 7ML5440-1AB00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1BB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1BB00-0AA1
Reference: 7ML5440-1BB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1BB00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1BB00-1AA1
Reference: 7ML5440-1BB00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1CB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1CB00-0AA1
Reference: 7ML5440-1CB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1CB00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1CB00-0AA2
Reference: 7ML5440-1CB00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1CB00-0BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1CB00-0BA1
Reference: 7ML5440-1CB00-0BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1CB00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1CB00-1AA1
Reference: 7ML5440-1CB00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1DB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1DB00-0AA1
Reference: 7ML5440-1DB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1DB00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1DB00-0AA2
Reference: 7ML5440-1DB00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1DB00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1DB00-1AA1
Reference: 7ML5440-1DB00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1EB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1EB00-0AA1
Reference: 7ML5440-1EB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1EB00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1EB00-0AA2
Reference: 7ML5440-1EB00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1EB00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1EB00-1AA1
Reference: 7ML5440-1EB00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1EB00-1AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1EB00-1AA2
Reference: 7ML5440-1EB00-1AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1FB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1FB00-0AA1
Reference: 7ML5440-1FB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1FB00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1FB00-0AA2
Reference: 7ML5440-1FB00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1FB00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1FB00-1AA1
Reference: 7ML5440-1FB00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1FB00-1AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1FB00-1AA2
Reference: 7ML5440-1FB00-1AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1GA00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GA00-0AA1
Reference: 7ML5440-1GA00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1GA00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GA00-0AA2
Reference: 7ML5440-1GA00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1GA00-0BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GA00-0BA1
Reference: 7ML5440-1GA00-0BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1GA00-0BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GA00-0BA2
Reference: 7ML5440-1GA00-0BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1GA00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GA00-1AA1
Reference: 7ML5440-1GA00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1GA00-1AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GA00-1AA2
Reference: 7ML5440-1GA00-1AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1GA00-1BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GA00-1BA1
Reference: 7ML5440-1GA00-1BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1GA00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GA00-1BA2
Reference: 7ML5440-1GA00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1GB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GB00-0AA1
Reference: 7ML5440-1GB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1GB00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GB00-0AA2
Reference: 7ML5440-1GB00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1GB00-0BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GB00-0BA1
Reference: 7ML5440-1GB00-0BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1GB00-0BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GB00-0BA2
Reference: 7ML5440-1GB00-0BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1GB00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GB00-1AA1
Reference: 7ML5440-1GB00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1GB00-1AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GB00-1AA2
Reference: 7ML5440-1GB00-1AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1GB00-1BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GB00-1BA1
Reference: 7ML5440-1GB00-1BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1GB00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1GB00-1BA2
Reference: 7ML5440-1GB00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 3" / 80 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1HA00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HA00-0AA1
Reference: 7ML5440-1HA00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1HA00-0BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HA00-0BA1
Reference: 7ML5440-1HA00-0BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1HA00-0BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HA00-0BA2
Reference: 7ML5440-1HA00-0BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1HA00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HA00-1AA1
Reference: 7ML5440-1HA00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1HA00-1BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HA00-1BA1
Reference: 7ML5440-1HA00-1BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1HA00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HA00-1BA2
Reference: 7ML5440-1HA00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1HB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HB00-0AA1
Reference: 7ML5440-1HB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1HB00-0BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HB00-0BA1
Reference: 7ML5440-1HB00-0BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1HB00-0BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HB00-0BA2
Reference: 7ML5440-1HB00-0BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1HB00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HB00-1AA1
Reference: 7ML5440-1HB00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1HB00-1AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HB00-1AA2
Reference: 7ML5440-1HB00-1AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1HB00-1BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HB00-1BA1
Reference: 7ML5440-1HB00-1BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1HB00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1HB00-1BA2
Reference: 7ML5440-1HB00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1JA00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JA00-0AA1
Reference: 7ML5440-1JA00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1JA00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JA00-0AA2
Reference: 7ML5440-1JA00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1JA00-0BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JA00-0BA1
Reference: 7ML5440-1JA00-0BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1JA00-0BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JA00-0BA2
Reference: 7ML5440-1JA00-0BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1JA00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JA00-1AA1
Reference: 7ML5440-1JA00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1JA00-1AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JA00-1AA2
Reference: 7ML5440-1JA00-1AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1JA00-1BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JA00-1BA1
Reference: 7ML5440-1JA00-1BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1JA00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JA00-1BA2
Reference: 7ML5440-1JA00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1JB00-0AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JB00-0AA1
Reference: 7ML5440-1JB00-0AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1JB00-0AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JB00-0AA2
Reference: 7ML5440-1JB00-0AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Tag: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1JB00-0BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JB00-0BA1
Reference: 7ML5440-1JB00-0BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1JB00-0BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JB00-0BA2
Reference: 7ML5440-1JB00-0BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 0.5 bar g (7.5 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 0.5 bar g (7.5 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1JB00-1AA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JB00-1AA1
Reference: 7ML5440-1JB00-1AA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1JB00-1AA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JB00-1AA2
Reference: 7ML5440-1JB00-1AA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: 4 to 20 mA, HART Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: 4 ... 20 mA, HART Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5440-1JB00-1BA1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JB00-1BA1
Reference: 7ML5440-1JB00-1BA1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5440-1JB00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1JB00-1BA2
Reference: 7ML5440-1JB00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum, with integral aimer Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 6" / 150 mm, painted aluminum with integrated fixing flange Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability
7ML5050-0AB12-1DA0 SIEMENS SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m ..

SIEMENS

Manufacturer Code: 7ML5050-0AB12-1DA0
Reference: 7ML5050-0AB12-1DA0
Catalog Number: -
SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: General Purpose CE, FM, CSA US/C, UL, RCM,EAC,KCC -
SITRANS LUT400 Ultrasonic Level Controller: Continuous, Non-Contact Measurement, 60 m (197 ft) Range. Monitors the level, volume, and volumetric flow in open channel of liquids, sludge, and solids. High accuracy in volumetric flow measurement and built-in data logging. - Version/Model: SITRANS LUT420 - Level Control Display Options (Box):With Remote Display for Panel Mounting Input Voltage: 100 ... 230 V AC +/- 15 % Cable input: 3 wiring ducts, 3 M20 plastic grommets provided Number of measurement points (channels): Single-channel instrument (includes an ultrasonic sensor input, an analog output, and an external temperature sensor input) Communications and I/O: HART, 2 digital inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC
Delivery: See availability
7ML5050-0BA22-1DA0 SIEMENS SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m ..

SIEMENS

Manufacturer Code: 7ML5050-0BA22-1DA0
Reference: 7ML5050-0BA22-1DA0
Catalog Number: -
SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT430 - Level, Pump & Flow controller Enclosure Display Options: With display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: General Purpose CE, FM, CSA US/C, UL, RCM,EAC,KCC -
SITRANS LUT400 Ultrasonic Level Controller: Continuous, Non-Contact Measurement, 60 m (197 ft) Range. Monitors the level, volume, and volumetric flow in open channel of liquids, sludge, and solids. High accuracy in volumetric flow measurement and built-in data logging. - Version/Model: SITRANS LUT430 - Level, pump and flow control Display options (box): With display Input voltage: 10 ... 32 V DC Cable input: 3 wiring ducts, 3 M20 plastic grommets provided Number of measurement points (channels): Single-channel instrument (includes an ultrasonic sensor input, an analog output, and an external temperature sensor input) Communications and I/O: HART, 2 digital inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC -
Delivery: See availability
7MF1566-3AA00-1AA1 SIEMENS SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure app..

SIEMENS

Manufacturer Code: 7MF1566-3AA00-1AA1
Reference: 7MF1566-3AA00-1AA1
Catalog Number: -
SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 100 mbar, Overload- pressure 400 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P210 Transmitter for Pressure for Low Pressure Applications Deviation from the type characteristic 0.25 percent Material of the elements in contact with the fluid: stainless steel and sealing material; Material of the parts that are not in contact with the fluid: stainless steel Measurement range for relative pressure: from 0 to 100 mbar, overload pressure of 400 mbar output signal: 4 to 20 mA two-wire connection auxiliary power: DC 7 to 33 V (DC 10...30 V for ATEX equipment) without explosion protection Electrical connection: connector according to DIN EN 175301-803-A, M16 gland thread (with coupling) process connection: G1/2" external according to EN837-1 (1/2"-BSP exterior); (standard with metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (F
Delivery: See availability
7MF1566-3AB00-1AA1 SIEMENS SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure app..

SIEMENS

Manufacturer Code: 7MF1566-3AB00-1AA1
Reference: 7MF1566-3AB00-1AA1
Catalog Number: -
SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 160 mbar, Overload- pressure 400 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P210 Transmitter for Pressure for Low Pressure Applications Deviation from the type characteristic 0.25 percent Material of the elements in contact with the fluid: stainless steel and sealing material; Material of the parts that are not in contact with the fluid: stainless steel Measuring range for relative pressure: from 0 to 160 mbar, overload pressure from 400 mbar output signal: 4 to 20 mA two-wire connection auxiliary power: DC 7 to 33 V (DC 10...30 V for ATEX equipment) without explosion protection Electrical connection: connector according to DIN EN 175301-803-A, M16 gland thread (with coupling) process connection: G1/2" external according to EN837-1 (1/2"-BSP exterior); (standard with metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (F
Delivery: See availability
7MF1566-3AC00-1AA1 SIEMENS SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure app..

SIEMENS

Manufacturer Code: 7MF1566-3AC00-1AA1
Reference: 7MF1566-3AC00-1AA1
Catalog Number: -
SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 250 mbar, Overload- pressure 1000 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P210 Transmitter for Pressure for Low Pressure Applications Deviation from the type characteristic 0.25 percent Material of the elements in contact with the fluid: stainless steel and sealing material; Material of the parts that are not in contact with the fluid: stainless steel Measurement range for relative pressure: from 0 to 250 mbar, overload pressure from 1000 mbar output signal: 4 to 20 mA two-wire connection auxiliary power: DC 7 to 33 V (DC 10...30 V for ATEX equipment) without explosion protection Electrical connection: connector according to DIN EN 175301-803-A, M16 gland thread (with coupling) process connection: G1/2" external according to EN837-1 (1/2"-BSP exterior); (standard with metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton
Delivery: See availability
7MF1566-3AD00-1AA1 SIEMENS SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure app..

SIEMENS

Manufacturer Code: 7MF1566-3AD00-1AA1
Reference: 7MF1566-3AD00-1AA1
Catalog Number: -
SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 400 mbar, Overload- pressure 1000 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS P210 Transmitter for Pressure for Low Pressure Applications Deviation from the type characteristic 0.25 percent Material of the elements in contact with the fluid: stainless steel and sealing material; Material of the parts that are not in contact with the fluid: stainless steel Measuring range for relative pressure: from 0 to 400 mbar, overload pressure from 1000 mbar output signal: 4 to 20 mA two-wire connection auxiliary power: DC 7 to 33 V (DC 10...30 V for ATEX equipment) without explosion protection Electrical connection: connector according to DIN EN 175301-803-A, M16 gland thread (with coupling) process connection: G1/2" external according to EN837-1 (1/2"-BSP exterior); (standard with metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (
Delivery: See availability
7ML5662-0BA00-0BB0 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0BB0
Reference: 7ML5662-0BA00-0BB0
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, UKCA, RCM, ATEX, UKEX II 1/2D Ex ia/tb Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0BC0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0BC0
Reference: 7ML5662-0BA00-0BC0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-tick, Atex II 1/2 D, 2 D IP6X T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Ac
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-tick, Atex II 1/2 D, 2 D IP6X T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0BD0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0BD0
Reference: 7ML5662-0BA00-0BD0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0CA0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0CA0
Reference: 7ML5662-0BA00-0CA0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapte
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active Shield Length: Standard Lengt
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4, ATEX II 1/2 D I IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Standard length - (125 mm
Delivery: See availability
7ML5662-0BA00-0CB0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0CB0
Reference: 7ML5662-0BA00-0CB0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Ent
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shield Length: Standard Length - (125 mm T
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4, ATEX II 1/2 D I IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105
Delivery: See availability
7ML5662-0BA00-0CC0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0CC0
Reference: 7ML5662-0BA00-0CC0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapte
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Length: Standard Lengt
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4, ATEX II 1/2 D I IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Standard length - (125 mm t
Delivery: See availability
7ML5662-0BA00-0CD0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0CD0
Reference: 7ML5662-0BA00-0CD0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminium, Epoxy Coated, 2 x M20 x 1.5 Cable En
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminium, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length: Standard Length - (125 mm
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4, ATEX II 1/2 D I IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105
Delivery: See availability
7ML5662-0BA00-0DA0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0DA0
Reference: 7ML5662-0BA00-0DA0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Standard le
Delivery: See availability
7ML5662-0BA00-0DB0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0DB0
Reference: 7ML5662-0BA00-0DB0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cab
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Standard length - (125 mm
Delivery: See availability
7ML5662-0BA00-0DC0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0DC0
Reference: 7ML5662-0BA00-0DC0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Standard len
Delivery: See availability
7ML5662-0BA00-0DD0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0DD0
Reference: 7ML5662-0BA00-0DD0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case & Lid: Aluminium, Epoxy Coated, 2 x M20 x 1.5 Ca
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm
Delivery: See availability
7ML5662-0BA00-0FA0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0FA0
Reference: 7ML5662-0BA00-0FA0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Co
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP65 Active
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length:
Delivery: See availability
7ML5662-0BA00-0FB0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0FB0
Reference: 7ML5662-0BA00-0FB0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Co
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP65 Active Shield Length
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Standard leng
Delivery: See availability
7ML5662-0BA00-0FC0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0FC0
Reference: 7ML5662-0BA00-0FC0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Co
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length:
Delivery: See availability
7ML5662-0BA00-0FD0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0FD0
Reference: 7ML5662-0BA00-0FD0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Co
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CSA/FM Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Case & Lid: Aluminum, Epoxy Coated, 2 x M20 x 1.5 Cable Entry, IP68 Active Shield Length
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard leng
Delivery: See availability
7ML5662-0BA00-0GA0 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0GA0
Reference: 7ML5662-0BA00-0GA0
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/ FM Class I, II, III Div. 1 Gr.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Class III T4 Case & Li
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shi
Delivery: See availability
7ML5662-0BA00-0GB0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0GB0
Reference: 7ML5662-0BA00-0GB0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, ta
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Class III T4 Case & Li
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: St
Delivery: See availability
7ML5662-0BA00-0HA0 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0HA0
Reference: 7ML5662-0BA00-0HA0
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose CSA, FM Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0HB0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0HB0
Reference: 7ML5662-0BA00-0HB0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0HC0 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0HC0
Reference: 7ML5662-0BA00-0HC0
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose CSA, FM Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0HD0 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0HD0
Reference: 7ML5662-0BA00-0HD0
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose CSA, FM Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0JA0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0JA0
Reference: 7ML5662-0BA00-0JA0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM, CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0JB0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0JB0
Reference: 7ML5662-0BA00-0JB0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (12
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP65 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM, CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BA00-0JD0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BA00-0JD0
Reference: 7ML5662-0BA00-0JD0
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (12
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Standard, 350 mm (13.78") rod Process side joints: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: General purpose (CSA, FM, CE, C-TICK) Case and lid: aluminum, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm flange)
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Standard version, rod 350 mm (13.78") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM, CE, C-TICK) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BB00-0BA1 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BB00-0BA1
Reference: 7ML5662-0BB00-0BA1
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") .
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for dust CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminum, epoxy coated, 2 x 1/2" NPT via adapter - Cable entry, IP65 Active Shield length: Extended display - (250 mm thre
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-0BB00-0BD0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BB00-0BD0
Reference: 7ML5662-0BB00-0BD0
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, UKCA, RCM, ATEX, UKEX II 1/2D Ex ia/tb Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Standard length - (125 mm thread, 105 mm fl
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm threaded, 105 mm flanged)
Delivery: See availability
7ML5662-0BB00-0BD1 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BB00-0BD1
Reference: 7ML5662-0BB00-0BD1
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, UKCA, RCM, ATEX, UKEX II 1/2D Ex ia/tb Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Ex protection for CE dust, C-tick, ATEX II 1/2 D, 2 D IP6X T100 C Case and lid: aluminium, epoxy coated, 2 x M20 x 1.5 Cable entry, IP68 Active Shield length: Extended display - (250 mm thread, 230 mm f
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged)
Delivery: See availability
7ML5662-0BB00-0CC0 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BB00-0CC0
Reference: 7ML5662-0BB00-0CC0
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") .
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Intrinsic safety CE, C-TICK, ATEX II 1 G EEx ia IIC T6... T4, ATEX II 1/2 D IP6X T100 C Case & Lid: Aluminum, Epoxy Coated, 2 x 1/2" NPT via Adapter - Cable Entry, IP68 Active Shield Length: Standar
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Intrinsically Safe CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4, ATEX II 1/2 D I IP6X T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Standard length - (125 mm th
Delivery: See availability
7ML5662-0BB00-0DD0 SIEMENS Pointek CLS300 RF Capacitance point level switch, digital, high temperature desig..

SIEMENS

Manufacturer Code: 7ML5662-0BB00-0DD0
Reference: 7ML5662-0BB00-0DD0
Catalog Number: -
Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, UKCA, RCM, ATEX, UKEX II 1/2G Ex ia/db; ATEX, UKEX II 1/2D Ex ia/tb Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof, fire-resistant enclosure with intrinsic safety probe (IS) CE probe, C-tick, ATEX II 1/2 G EEx d(ia) IIC T6... T4, ATEX II 1/2 D T100 C Case & Lid: Aluminium, Epoxy Coated, 2 x M20 x
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Flameproof Enclosure with IS Probe: CE, C-TICK, ATEX II 1/2 G EEx d(ia) IIC T6...T4, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 Active Shield Length: Standard length - (125 mm
Delivery: See availability
7ML5662-0BB00-0GA1 SIEMENS Pointek CLS300 Digital, High Temperature Rod Version with Threaded Connection or ..

SIEMENS

Manufacturer Code: 7ML5662-0BB00-0GA1
Reference: 7ML5662-0BB00-0GA1
Catalog Number: -
Pointek CLS300 - Digital, High Temperature Rod Version with Threaded Connection or Process Flange Connection: Capacitive, versatile with Inverse Frequency Frequency Shift, with optional rod/cable probes and configurable output. It is ideal for the detection of liquids, granular solids, mud, foam and interfaces under conditions of difficult use conditions with high pressure and elevated temperatures. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div
. Pointek CLS300 RF Capacitive Level Switch, Digital, High Temperature Variant. Level and level/interface detection of aggressive liquids, solids, slurries and foam. Insertion length 1 m (3.28 ft) adjustable, sensitivity adjustable, with Active Shield technology to ignore buildup in the probe. With digital indication and communication module. Process connection: 1" NPT (tapered), ANSI/ASME B1.20.1 Probe length: (length from flange face) Rod extension, length 500 mm (19.69") Process side seals: Graphite Probe material: stainless steel, mat no. 1.4404/316L with ceramic insulators Approvals: Explosion-proof enclosure (explosion protected) with intrinsically safe (IS) CSA/FM Probe Class I, Div. 1, Tam. A, B, C, D, CSA/FM Class II, Div. 1, tam. E, F, G, CSA/FM Class III T4 Class III T4 Case a
Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: 1" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended rod, length 500 mm (19.69") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Gr. A, B, C, D, CSA/FM Class II, Div. 1, Gr. E, F, G, CSA/FM Class III T4 Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 Active Shie
Delivery: See availability

products sitemap