Viewed products

Electromechanical starters - LOVATO ELECTRIC

Electromechanical starters from LOVATO ELECTRIC are engineered for robust motor control in industrial environments. These devices integrate contactors, thermal overload relays, and enclosures into a single assembly, offering configurations like direct-on-line (DOL), reversing, star-delta, and changeover starters. Key technical parameters include...

Electromechanical starters from LOVATO ELECTRIC are engineered for robust motor control in industrial environments. These devices integrate contactors, thermal overload relays, and enclosures into a single assembly, offering configurations like direct-on-line (DOL), reversing, star-delta, and changeover starters. Key technical parameters include rated operational currents up to 170A at 400V AC, utilization categories AC-3 and AC-4 for squirrel-cage motors, and thermal relay adjustment ranges from 0.1A to 170A. The starters feature screw or spring-clamp terminals, IP65-rated enclosures for dust and water ingress protection, and comply with IEC/EN 60947-4-1 standards. Options include versions with or without integrated thermal relays, and empty non-metallic enclosures for custom assemblies.

These starters are primarily deployed in motor control centers (MCCs), industrial automation panels, and pumping stations. They are ideal for controlling three-phase induction motors in conveyors, compressors, fans, and machine tools. The reversing and changeover variants are critical for bidirectional motor drives and standby power systems. Star-delta configurations reduce inrush current during motor startup, making them suitable for high-inertia loads like centrifuges and crushers. The enclosures are designed for wall-mounting or panel integration in harsh environments, including chemical plants and wastewater treatment facilities.

Key subcategories include the LO130 series of DOL starters with thermal overload protection, available in frame sizes from 9A to 170A. The LO130..R series offers reversing contactor assemblies, while LO130..C covers changeover configurations. Star-delta starters are coded as LO130..SD, with options for open or enclosed versions. The empty enclosures, like the LO130..E series, come in sizes from 4 to 12 modules, allowing custom assembly. Article codes typically follow the pattern LO130-xxx-xx, where the first digits indicate current rating and suffix denotes configuration (e.g., -R for reversing, -SD for star-delta).

Partnering with Electric Automation Network ensures access to genuine LOVATO ELECTRIC starters with real-time pricing and global express shipping. Our engineering team provides tailored technical support for selecting the correct starter configuration, thermal relay setting, and enclosure type. We offer detailed documentation including wiring diagrams, derating curves, and compliance certificates. Whether you need a single unit for a retrofit or bulk orders for a new installation, we streamline procurement with multilingual assistance and fast delivery worldwide.

More
Number of products per page:
Order:
Manufacturer Code Reference Catalog Number Description Delivery Price

BGR0901D012

11BGR0901D012

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, EXTERNAL INTERLOCK WITH POWER AND AUXILIARY WIRING, 9A AC3 IN DC, 4KW. COIL VOLTAGE12VDC

9A AC3 Inverter Encl. External, Conex. Pot./Cont. 12V DC

Reversing contactor assembly, DC coil, external interlock with power and auxiliary wiring, 9A AC3 in DC, 4kW. Coil voltage 12VDC

3 View Availability View Price

BGR0901D024

11BGR0901D024

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, EXTERNAL INTERLOCK WITH POWER AND AUXILIARY WIRING, 9A AC3 IN DC, 4KW. COIL VOLTAGE 24VDC

9A AC3 Inverter Encl. External, Conex. Pot./Cont. 24V DC

Reversing contactor assembly, DC coil, external interlock with power and auxiliary wiring, 9A AC3 in DC, 4kW. Coil voltage 24VDC

3 View Availability View Price

BGR0901D048

11BGR0901D048

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, EXTERNAL INTERLOCK WITH POWER AND AUXILIARY WIRING, 9A AC3 IN DC, 4KW. COIL VOLTAGE 48VDC

9A AC3 Inverter Encl. External, Conex. Pot./Cont. 48V DC

Reversing contactor assembly, DC coil, external interlock with power and auxiliary wiring, 9A AC3 in DC, 4kW. Coil voltage 48VDC

3 View Availability View Price

BGR0901D060

11BGR0901D060

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, EXTERNAL INTERLOCK WITH POWER AND AUXILIARY WIRING, 9A AC3 IN DC, 4KW. COIL VOLTAGE 60VDC

9A Enclav Inverter. External 2 NC 60V DC

Reversing contactor assembly, DC coil, external interlock with power and auxiliary wiring, 9A AC3 in DC, 4kW. Coil voltage 60VDC

3 View Availability View Price

BGR1201D012

11BGR1201D012

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, EXTERNAL INTERLOCK WITH POWER AND AUXILIARY WIRING, 12A AC3 IN DC, 5.7KW. COIL VOLTAGE12VDC

Inverter 12A AC3 Encl. External, Conex. Pot./Cont. 12V DC

Reversing contactor assembly, DC coil, external interlock with power and auxiliary wiring, 12A AC3 in DC, 5.7kW. Coil voltage 12VDC

3 View Availability View Price

BGR1201D024

11BGR1201D024

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, EXTERNAL INTERLOCK WITH POWER AND AUXILIARY WIRING, 12A AC3 IN DC, 5.7KW. COIL VOLTAGE 24VDC

Inverter 12A AC3 Encl. External, Conex. Pot./Cont. 24V DC

Reversing contactor assembly, DC coil, external interlock with power and auxiliary wiring, 12A AC3 in DC, 5.7kW. Coil voltage 24VDC

3 View Availability View Price

BGR1201D060

11BGR1201D060

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, EXTERNAL INTERLOCK WITH POWER AND AUXILIARY WIRING, 12A AC3 IN DC, 5.7KW. COIL VOLTAGE 60VDC

12A Enclav Inverter. External 2 NC 60V DC

Reversing contactor assembly, DC coil, external interlock with power and auxiliary wiring, 12A AC3 in DC, 5.7kW. Coil voltage 60VDC

3 View Availability View Price

BGR1201D048

11BGR1201D048

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, EXTERNAL INTERLOCK WITH POWER AND AUXILIARY WIRING, 12A AC3 IN DC, 5.7KW. COIL VOLTAGE 48VDC

12A Enclav Inverter. External 2 NC 48V DC

Reversing contactor assembly, DC coil, external interlock with power and auxiliary wiring, 12A AC3 in DC, 5.7kW. Coil voltage 48VDC

3 View Availability View Price

BGT0910D012

11BGT0910D012

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK WITH POWER WIRING ONLY, 9A AC3 IN DC, 4KW. COIL VOLTAGE12VDC

9A Enclav Inverter. internal 2 NA 12V DC

Reversing contactor assembly, DC coil, built-in interlock with power wiring only, 9A AC3 in DC, 4kW. Coil voltage 12VDC

3 View Availability View Price

BGT0910D024

11BGT0910D024

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK WITH POWER WIRING ONLY, 9A AC3 IN DC, 4KW. COIL VOLTAGE 24VDC

9A AC3 Inverter Encl. Internal, Connected. Pot. 24V DC

Reversing contactor assembly, DC coil, built-in interlock with power wiring only, 9A AC3 in DC, 4kW. Coil voltage 24VDC

3 View Availability View Price

BGT0910D048

11BGT0910D048

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK WITH POWER WIRING ONLY, 9A AC3 IN DC, 4KW. COIL VOLTAGE 48VDC

9A AC3 Inverter Encl. Internal, Connected. Pot. 48V DC

Reversing contactor assembly, DC coil, built-in interlock with power wiring only, 9A AC3 in DC, 4kW. Coil voltage 48VDC

3 View Availability View Price

BGT0910D060

11BGT0910D060

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK WITH POWER WIRING ONLY, 9A AC3 IN DC, 4KW. COIL VOLTAGE 60VDC

9A Enclav Inverter. internal 2 NA 60V DC

Reversing contactor assembly, DC coil, built-in interlock with power wiring only, 9A AC3 in DC, 4kW. Coil voltage 60VDC

3 View Availability View Price

BGT1210D024

11BGT1210D024

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK WITH POWER WIRING ONLY, 12A AC3 IN DC, 5.7KW. COIL VOLTAGE 24VDC

Inverter 12A AC3 Encl. Internal, Connected. Pot. 24V DC

Reversing contactor assembly, DC coil, built-in interlock with power wiring only, 12A AC3 in DC, 5.7kW. Coil voltage 24VDC

3 View Availability View Price

BGT1210D048

11BGT1210D048

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK WITH POWER WIRING ONLY, 12A AC3 IN DC, 5.7KW. COIL VOLTAGE 48VDC

Inverter 12A AC3 Encl. Internal, Connected. Pot. 48V DC

Reversing contactor assembly, DC coil, built-in interlock with power wiring only, 12A AC3 in DC, 5.7kW. Coil voltage 48VDC

3 View Availability View Price

BGT1210D012

11BGT1210D012

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK WITH POWER WIRING ONLY, 12A AC3 IN DC, 5.7KW. COIL VOLTAGE12VDC

12A Enclav Inverter. internal 2 NA 12V DC

Reversing contactor assembly, DC coil, built-in interlock with power wiring only, 12A AC3 in DC, 5.7kW. Coil voltage 12VDC

3 View Availability View Price

BGT1210D060

11BGT1210D060

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK WITH POWER WIRING ONLY, 12A AC3 IN DC, 5.7KW. COIL VOLTAGE 60VDC

12A Enclav Inverter. internal 2 NA 60V DC

Reversing contactor assembly, DC coil, built-in interlock with power wiring only, 12A AC3 in DC, 5.7kW. Coil voltage 60VDC

3 View Availability View Price

BGTP0901D012

11BGTP0901D012

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK ONLY WITH REAR PCB SOLDER PINS, 9A AC3 IN DC, 4KW. COIL VOLTAGE12VDC

9A Enclav Inverter. Internal 2 NC 12V DC

Reversing contactor assembly, DC coil, built-in interlock only with rear PCB solder pins, 9A AC3 in DC, 4kW. Coil voltage 12VDC

3 View Availability View Price

BGTP0901D024

11BGTP0901D024

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK ONLY WITH REAR PCB SOLDER PINS, 9A AC3 IN DC, 4KW. COIL VOLTAGE 24VDC

9A Enclav Inverter. internal 2 NC 24V DC

Reversing contactor assembly, DC coil, built-in interlock only with rear PCB solder pins, 9A AC3 in DC, 4kW. Coil voltage 24VDC

3 View Availability View Price

BGTP0901D048

11BGTP0901D048

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK ONLY WITH REAR PCB SOLDER PINS, 9A AC3 IN DC, 4KW. COIL VOLTAGE 48VDC

9A Enclav Inverter. Internal 2 NC 48V DC

Reversing contactor assembly, DC coil, built-in interlock only with rear PCB solder pins, 9A AC3 in DC, 4kW. Coil voltage 48VDC

3 View Availability View Price

BGTP0901D060

11BGTP0901D060

-

REVERSING CONTACTOR ASSEMBLY, DC COIL, BUILT-IN INTERLOCK ONLY WITH REAR PCB SOLDER PINS, 9A AC3 IN DC, 4KW. COIL VOLTAGE 60VDC

9A Enclav Inverter. Internal 2 NC 60V DC

Reversing contactor assembly, DC coil, built-in interlock only with rear PCB solder pins, 9A AC3 in DC, 4kW. Coil voltage 60VDC

3 View Availability View Price

M0P009120241

M0P009120241

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 1A MAX (0.18…0.25KW AT 400V), IP65. CONTACTOR COIL VOLTAGE 24VAC 50/60HZ

DOL STARTER M0P 24/50-60 0,6-1A

Direct-on-line-starter, 0.6...1A (0.18...0.25kW at 400V), IP65, contactor coil voltage 24VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

3 View Availability View Price

M0P009120245

M0P009120245

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 5A MAX (1.5…2.2KW AT 400V), IP65. CONTACTOR COIL VOLTAGE 24VAC 50/60HZ

DOL STARTER M0P 24/50-60 3-5A

Direct-on-line-starter, 3...5A (1.5...2.2kW at 400V), IP65, contactor coil voltage 24VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

3 View Availability View Price

M0P009122302V3

M0P009122302V3

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 2.3A MAX (0.55…0.75KW A 400V), IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ

DOL STARTER M0P 230/50-60 1,4-2,3A

Direct-on-line-starter, 1.4...2.3A (0.55...0.75kW at 400V), IP65, contactor coil voltage 230VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

2 View Availability View Price

M0P009122301V5

M0P009122301V5

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 1.5A MAX (0.37KW A 400V), IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ

DOL STARTER M0P 230/50-60 0,9-1,5A

Direct-on-line-starter, 0.9…1.5A (0.37kW at 400V), IP65, contactor coil voltage 230VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

3 View Availability View Price

M0P009122301

M0P009122301

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 1A MAX (0.18…0.25KW AT 400V), IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ

DOL STARTER M0P 230/50-60 0,6-1A

Direct-on-line-starter, 0.6...1A (0.18...0.25kW at 400V), IP65, contactor coil voltage 230VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

3 View Availability View Price

M0P0091223033

M0P0091223033

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 3.3A MAX (1.1KW A 400V), IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ

DOL STARTER M0P 230/50-60 2-3,3A

Direct-on-line-starter, 2...3.3A (1.1kW at 400V), IP65, contactor coil voltage 230VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

2 View Availability View Price

M0P0091223010

M0P0091223010

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 10A MAX (3…4KW AT 400V), IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ

DOL STARTER M0P 230/50-60 6-10A

Direct-on-line-starter, 6...10A (3...4kW at 400V), IP65, contactor coil voltage 230VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

3 View Availability View Price

M0P009122305

M0P009122305

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 5A MAX (1.5…2.2KW AT 400V), IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ

DOL STARTER M0P 230/50-60 3-5A

Direct-on-line-starter, 3...5A (1.5...2.2kW at 400V), IP65, contactor coil voltage 230VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

3 View Availability View Price

M0P0091223075

M0P0091223075

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 7.5A MAX (2.2…3KW A 400V), IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ

DOL STARTER M0P 230/50-60 4,5-7,5A

Direct-on-line-starter, 4.5...7.5A (2.2...3kW at 400V), IP65, contactor coil voltage 230VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

3 View Availability View Price

M0P009124001

M0P009124001

-

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH START AND STOP/RESET BUTTONS, WITH BG09/BG12 CONTACTOR, 1A MAX (0.18…0.25KW AT 400V), IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ

DOL STARTER M0P 400/50-60 0,6-1A

Direct-on-line-starter, 0.6...1A (0.18...0.25kW at 400V), IP65, contactor coil voltage 400VAC 50/60Hz, non-metallic enclosure, with thermal overload relay, with START and STOP/RESET buttons

3 View Availability View Price

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.

products sitemap