DTZ16(*/*)* 914814 Y7-914814 EATON ELECTRIC Three-phase control/isolation/safety transformer, 1.6kVA, non-st.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DTZ16(*/*)* 914814 Y7-914814 EATON ELECTRIC Three-phase control/isolation/safety transformer, 1.6kVA, non-st..

DTZ16(*/*)*

914814

Y7-914814

EATON-MOELLER

Three-phase control/isolation/safety transformer, 1.6kVA, non-standard voltage

DTZ16(*/*)*

Three-phase control isolating safety transformer, 16 kVA, Rated input voltage 50 – 950 ± 5 % V, Rated output voltage 18.5 – 1000 V

Three-phase control transformer performed according to VDE 0550, VDE 0550 part1, IEC/EN 61558-2-2, VDE0570 part 2-2 as safety transformer VDE 0570 part 2-6 and as isolating transformer VDE 0570 part 2-4, OVE. Rated input voltage selectable of 50-950V +-5%, rated output voltage can be selected from 18.5 - 1000 rated power 16 kVA (*/*) = wildcard for rated input voltage / rated output voltage

More details


Low-voltage industrial components > Three-phase control transformer

Transformers

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article is restricted. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Three-phase control isolating safety transformer, 16 kVA, Rated input voltage 50 – 950 ± 5 % V, Rated output voltage 18.5 – 1000 V
Three-phase control transformer performed according to VDE 0550, VDE 0550 part1, IEC/EN 61558-2-2, VDE0570 part 2-2 as safety transformer VDE 0570 part 2-6 and as isolating transformer VDE 0570 part 2-4, OVE. Rated input voltage selectable of 50-950V +-5%, rated output voltage can be selected from 18.5 - 1000 rated power 16 kVA (*/*) = wildcard for rated input voltage / rated output voltage

General specifications
Product name
Eaton Moeller® series DTZ Control transformer
Part no.
DTZ16(*/*)*
Product Length/Depth
221 millimetre
Product height
434 millimetre
Product width
450 millimetre
Product weight
95 kilogram
Certifications
CE
IEC/EN 61558-2-2
UL Category Control No.: XPTQ2, XPTQ8
Product Tradename
DTZ
Product Type
Control transformer
Product Sub Type
None
General information
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
40 °C
Degree of protection
IP00
NEMA Other
Product category
Three-phase DTZ control transformers
Suitable for
Branch circuits, (UL/CSA)
Electrical rating
Rated power
16000 V·A
Relative short-circuit voltage
4.5 %
Short-time rating
40 kV·A
Voltage rating - max
600 V
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
520 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Three-phase control transformer (EC002485)
Electric engineering, automation, process control engineering / Transformer, converter, coil / Control transformer / Three-phase control transformer (ecl@ss13-27-03-13-01 [AAB619020])
Built as safety transformer
Yes
Built as isolating transformer
Yes
Built as energy saving transformer
No
Primary voltage 1
50 - 950 V
Primary voltage 2
50 - 950 V
Primary voltage 3
50 - 950 V
Primary voltage 4
50 - 950 V
Primary voltage 5
50 - 950 V
Primary voltage 6
50 - 950 V
Primary voltage 7
0 - 0 V
Primary voltage 8
0 - 0 V
Primary voltage 9
0 - 0 V
Primary voltage 10
0 - 0 V
Secondary voltage 1
18.5 - 1000 V
Secondary voltage 2
18.5 - 1000 V
Secondary voltage 3
18.5 - 1000 V
Secondary voltage 4
18.5 - 1000 V
Secondary voltage 5
18.5 - 1000 V
Secondary voltage 6
18.5 - 1000 V
Secondary voltage 7
0 - 0 V
Secondary voltage 8
0 - 0 V
Secondary voltage 9
0 - 0 V
Secondary voltage 10
0 - 0 V
Wiring system
Other
Rated power
16000 VA
Type of insulation material according to IEC 85
B
Short-circuit-proof
No
Relative short circuit voltage
4.5 %
Conductor material
Copper
Width
450 mm
Height
434 mm
Depth
221 mm
Degree of protection (IP)
IP00
Degree of protection (NEMA)
Other

ETIM for 914814 Low-voltage industrial controls and switchgear (EC002485)
Feature Name Feature Value
Built as safety transformer (EF007235) Yes
Built as isolating transformer (EF007238) Yes
Built as energy saving transformer (EF007005) No
Primary voltage 1 (EF006125) 50 V
Primary voltage 2 (EF006126) 50 V
Primary voltage 3 (EF006127) 50 V
Primary voltage 4 (EF007410) 50 V
Primary voltage 5 (EF007411) 50 V
Primary voltage 6 (EF007412) 50 V
Primary voltage 7 (EF007413) 0 V
Primary voltage 8 (EF007414) 0 V
Primary voltage 9 (EF007415) 0 V
Primary voltage 10 (EF007409) 0 V
Secondary voltage 1 (EF007472) 18.5 V
Secondary voltage 2 (EF007474) 18.5 V
Secondary voltage 3 (EF007475) 18.5 V
Secondary voltage 4 (EF007476) 18.5 V
Secondary voltage 5 (EF007477) 18.5 V
Secondary voltage 6 (EF007478) 18.5 V
Secondary voltage 7 (EF007479) 0 V
Secondary voltage 8 (EF007480) 0 V
Secondary voltage 9 (EF007481) 0 V
Secondary voltage 10 (EF007473) 0 V
Wiring system (EF002960) Other
Rated power (EF007051) 16000 VA
Type of insulation material according to IEC 85 (EF007299) B
Short-circuit-proof (EF007332) No
Relative short circuit voltage (EF007452) 4.5 %
Conductor material (EF001622) Copper
Width (EF000008) 450 mm
Height (EF000040) 434 mm
Depth (EF000049) 221 mm
Degree of protection (IP) (EF005474) IP00
Degree of protection (NEMA) (EF011959) Other

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.