Viewed products

End piece for fire-resistant duct

End Piece for Fire-Resistant Duct – Technical Overview and Supply

Block 1: Technical Introduction
End pieces for fire-resistant ducts are critical components designed to seal and terminate fire-rated cable management systems. These accessories are typically manufactured from intumescent materials or galvanized steel with fire-resistant coatings, e...

End Piece for Fire-Resistant Duct – Technical Overview and Supply

Block 1: Technical Introduction
End pieces for fire-resistant ducts are critical components designed to seal and terminate fire-rated cable management systems. These accessories are typically manufactured from intumescent materials or galvanized steel with fire-resistant coatings, ensuring they maintain circuit integrity and compartmentation during a fire event. They are available in various dimensions to match standard duct widths and depths, often featuring pre-scored knockouts for cable entry and integrated sealing gaskets. The end pieces must comply with international fire protection standards such as BS 476, EN 1366, or UL 263, depending on the region. In technical terms, these are also referred to as firestop duct end caps, fire-rated termination plates, or fire-resistant duct closures.

Block 2: Applications and Sectors
These end pieces are primarily installed in commercial, industrial, and infrastructure projects where fire-resistant cable management is mandatory. Typical environments include electrical substations, data centers, tunnels, hospitals, and high-rise buildings. They are used to terminate fire-resistant duct runs at walls, floors, or ceilings, ensuring that the fire compartmentation is not compromised. In automation and control panels, they help maintain the fire rating of cable entry points, preventing the spread of flames and hot gases.

Block 3: Subcategories and Key Articles
The main subcategories within this category include standard end pieces for rectangular fire-resistant ducts, adjustable end pieces for variable duct depths, and pre-drilled end pieces for specific cable configurations. Key article codes often follow a pattern such as "FREP-XXX" where XXX denotes the duct width in millimeters (e.g., FREP-100, FREP-200). Other common codes include "FDC-150" or "ET-FR-300", indicating the duct size and material type. These articles are typically sold as single units or in packs of 10 for bulk installations.

Block 4: Business Benefits and Support
At Electric Automation Network, we offer express worldwide shipping for all fire-resistant duct end pieces, ensuring your project deadlines are met. Our team of specialized electrical engineers provides personalized technical support to help you select the correct end piece for your fire-rated system, including compatibility with existing duct brands and firestop sealants. We also provide detailed technical documentation for each article, including installation guides and fire test certificates, to ensure compliance with local regulations.

More
Number of products per page:
Order:
Manufacturer Code Reference Catalog Number Description Delivery Price

7215250

BSK-E090506

-

End piece for BSK I90/E30, 95x120, Grey, Glass-fibre lightweight concrete

3 View Availability View Price

7215252

BSK-E090511

-

End piece for BSK I90/E30, 95x170, Grey, Glass-fibre lightweight concrete

3 View Availability View Price

7215254

BSK-E090521

-

End piece for BSK I90/E30, 95x270, Grey, Glass-fibre lightweight concrete

3 View Availability View Price

7215256

BSK-E091016

-

End piece for BSK I90/E30, 150x220, Grey, Glass-fibre lightweight concrete

3 View Availability View Price

7215258

BSK-E091026

-

End piece for BSK I90/E30, 150x320, Grey, Glass-fibre lightweight concrete

3 View Availability View Price

7215270

BSK-E120506

-

End piece for BSK I120/E90, 130x180, Grey, Glass-fibre lightweight concrete

End piece for PYROLINE® Con D BSK I120/E90. End piece for PYROLINE® Con D BSK I120/EI90 fire protection duct, consisting of fibreglass lightweight concrete which is resistant to water and frost for closing the duct ends.Including countersunk head screws and a stick-on sealing strip.

3 View Availability View Price

7215272

BSK-E120511

-

End piece for BSK I120/E90, 130x230, Grey, Glass-fibre lightweight concrete

End piece for PYROLINE® Con D BSK I120/E90. End piece for PYROLINE® Con D BSK I120/EI90 fire protection duct, consisting of fibreglass lightweight concrete which is resistant to water and frost for closing the duct ends.Including countersunk head screws and a stick-on sealing strip.

3 View Availability View Price

7215274

BSK-E120521

-

End piece for BSK I120/E90, 130x330, Grey, Glass-fibre lightweight concrete

End piece for PYROLINE® Con D BSK I120/E90. End piece for PYROLINE® Con D BSK I120/EI90 fire protection duct, consisting of fibreglass lightweight concrete which is resistant to water and frost for closing the duct ends.Including countersunk head screws and a stick-on sealing strip.

3 View Availability View Price

7215276

BSK-E121016

-

End piece for BSK I120/E90, 185x280, Grey, Glass-fibre lightweight concrete

3 View Availability View Price

7215278

BSK-E121026

-

End piece for BSK I120/E90, 185x380, Grey, Glass-fibre lightweight concrete

3 View Availability View Price

7216360

BSKM-VK 0711

-

End piece , 70x110, Strip-galvanised, DIN EN 10147, Steel, St

3 View Availability View Price

7216460

BSKM-VK 1025

-

End piece , 100x250, Strip-galvanised, DIN EN 10147, Steel, St

3 View Availability View Price

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.