Product successfully added to your shopping cart
1SDA073256R1
ABB
1
E6.2V 5000 Ekip Touch LSIG 4p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E6.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2364 |
| Environmental Product Declaration - EPD | 9AKK108468A1905 |
| 9AKK108468A1913 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 77 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 02c455b9-d2a3-4d75-84ed-5de3b8dc6202 Italy |
| Simplified SCIP | 6a4ec43b-55ea-4a6a-bac1-a84a15a9fc51 Germany |
| 87a66d14-2847-46ed-ad53-65257975811f Bulgaria | |
| 7a1f8e93-fc9f-40b8-8201-ddac1f76a653 Denmark | |
| b89f6bd5-722c-4362-b7bd-1723ce381247 Germany | |
| 1c3ed60e-79d2-4073-bea3-9a70d579e439 Portugal | |
| ad959372-197e-4773-88d3-67841f21bbae Germany | |
| b871b484-0963-4c6c-80d2-11e15b69bfe5 Sweden | |
| 407c9695-786c-4d89-aeda-d0d37446878c Croatia | |
| e0c9b09f-6901-489d-bf11-5b63825d5158 Netherlands | |
| 20abbcc6-21e8-4799-b183-177cd83e06fb Hungary | |
| 407c9695-786c-4d89-aeda-d0d37446878c Croatia | |
| a953486e-e8ca-457f-aefc-48992745b442 Norway | |
| d55db982-8695-419c-a858-4b55c6ecc697 Poland | |
| 7a1f8e93-fc9f-40b8-8201-ddac1f76a653 Denmark | |
| 949826c7-56e7-447f-936a-d12583137b0b France | |
| 48edcb51-67bf-42d8-84f4-c7878ed46dd2 Greece | |
| a85fe36b-c60a-42b8-889d-3280f0c5e3f5 Germany | |
| 23b2d9de-8e36-4011-9f16-b3fe5859c80e Finland | |
| 48edcb51-67bf-42d8-84f4-c7878ed46dd2 Greece | |
| dae0848e-d5a0-412d-b8bb-2ab5e3f06ad2 Poland | |
| 1c3ed60e-79d2-4073-bea3-9a70d579e439 Portugal | |
| d55db982-8695-419c-a858-4b55c6ecc697 Poland | |
| e3eb225d-45db-4371-8247-cb2e7c24fb09 Germany | |
| b89f6bd5-722c-4362-b7bd-1723ce381247 Germany | |
| ad959372-197e-4773-88d3-67841f21bbae Germany | |
| 85de8c19-5213-4a7a-8501-7a12d785c2a5 Hungary | |
| 394a0471-7251-49ab-a484-cac36bb5330d France | |
| 5c038b73-0c66-4566-a35c-6de7886dbc34 Spain | |
| 5c038b73-0c66-4566-a35c-6de7886dbc34 Spain | |
| 363fc6fa-e994-4c7f-bf67-e48d8a721605 Belgium | |
| ee514740-6254-4bbe-9b7f-af129ed0890d Estonia | |
| c4a9f6fc-dd10-4ea5-b1e0-083dbfbfb981 Poland | |
| cbfd9188-28e7-4420-ac14-2bbb9c923c31 Sweden | |
| 949826c7-56e7-447f-936a-d12583137b0b France | |
| b871b484-0963-4c6c-80d2-11e15b69bfe5 Sweden | |
| 87a66d14-2847-46ed-ad53-65257975811f Bulgaria | |
| e0c9b09f-6901-489d-bf11-5b63825d5158 Netherlands | |
| ec968fb0-2a73-4d7e-ac5a-8c67a77cf0ec Czech Republic | |
| ee514740-6254-4bbe-9b7f-af129ed0890d Estonia | |
| 20abbcc6-21e8-4799-b183-177cd83e06fb Hungary | |
| 394a0471-7251-49ab-a484-cac36bb5330d France | |
| dae0848e-d5a0-412d-b8bb-2ab5e3f06ad2 Poland | |
| 85de8c19-5213-4a7a-8501-7a12d785c2a5 Hungary | |
| 6a4ec43b-55ea-4a6a-bac1-a84a15a9fc51 Germany | |
| e3eb225d-45db-4371-8247-cb2e7c24fb09 Germany | |
| cbfd9188-28e7-4420-ac14-2bbb9c923c31 Sweden | |
| ec968fb0-2a73-4d7e-ac5a-8c67a77cf0ec Czech Republic | |
| c4a9f6fc-dd10-4ea5-b1e0-083dbfbfb981 Poland | |
| eec3e6a0-6d2a-4196-8ca0-5c1de96fe360 Belgium | |
| a85fe36b-c60a-42b8-889d-3280f0c5e3f5 Germany | |
| 23b2d9de-8e36-4011-9f16-b3fe5859c80e Finland | |
| 363fc6fa-e994-4c7f-bf67-e48d8a721605 Belgium | |
| a953486e-e8ca-457f-aefc-48992745b442 Norway | |
| eec3e6a0-6d2a-4196-8ca0-5c1de96fe360 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZDVXESAF000A000000XX |
| EAN | 8015644771065 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 929 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 134 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1127 mm |
| Package Level 1 Gross Weight | 143 kg |
| Package Level 1 EAN | 8015644771065 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0289 |
| Technical | |
| Connecting Capacity | 5000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 2000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 50 % |
| Number of Poles | 4P |
| Power Loss | 850 W |
| Rated Current (In) | 5000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 130 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 130 kA | |
| (525 V AC) 130 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 5000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E6.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5544 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001060R0105 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 5000 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 150 kA |
| Overload release current setting (EF002336) | 2000.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 3000.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 7500.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E6.2V 5000 Ekip Touch LSIG 4p WMP - ABB - E6.2V5000 - 1SDA073256R1 | 95 Kbytes |
![]() |
| E6.2V5000 1SDA073256R1 ABB E6.2V 5000 Ekip Touch LSIG 4p WMP | 86 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.