Product successfully added to your shopping cart
1SDA073188R1
ABB
1
E4.2S 4000 Ekip Hi-Touch LSI 4p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E4.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 0be96f17-f4a2-4642-8df7-e78ce99b8d2a Italy |
| Simplified SCIP | fcbbf69f-0ff0-4634-b99f-9bea61ba3040 Portugal |
| 47041d43-aed0-4e50-a911-c91d6f1e3392 Sweden | |
| 26643410-dbd9-4b71-9484-a6e877b97c7f Germany | |
| ddb74f2c-9f48-42a9-93df-d8fece47ab44 France | |
| dc0e25f9-4c3f-4660-94e0-3105c1c6891c Hungary | |
| 59c3e9b3-0c6d-4eb5-9886-332fe7b094b4 France | |
| 1df997d6-90ee-4f5d-a8d9-2637bf076056 Poland | |
| d3dbd096-a7e3-4a8d-9deb-eac7c85bded9 Estonia | |
| 466583cb-a1ae-45a6-8e47-e3cc3594e9bb Hungary | |
| d3dbd096-a7e3-4a8d-9deb-eac7c85bded9 Estonia | |
| 9d8d6e66-9c0d-4afb-95db-f017560a42b1 Spain | |
| 466583cb-a1ae-45a6-8e47-e3cc3594e9bb Hungary | |
| 9d8d6e66-9c0d-4afb-95db-f017560a42b1 Spain | |
| 386b877e-e1d1-40f1-93c4-e1e5d6056b35 Germany | |
| 97f608a7-9549-4b48-a006-b313924d3316 Denmark | |
| 7784ab44-9778-469e-b5e0-bff4ff9923a0 Bulgaria | |
| e2b18dde-c814-4c3d-86c4-bcc332ffaeff Germany | |
| 674b03f8-d62f-4dcb-b9bb-fc9b26d63b48 Norway | |
| ff373d02-ff5c-4255-b2f9-530865e1b7ce Belgium | |
| e2b18dde-c814-4c3d-86c4-bcc332ffaeff Germany | |
| ff373d02-ff5c-4255-b2f9-530865e1b7ce Belgium | |
| e2928cbd-91eb-4feb-a804-8bf127ff03c6 Finland | |
| 16a9554e-9bdf-4c56-8a95-1577e48abc14 Poland | |
| 840626a5-9112-49f1-b2e0-f9e301507c97 Czech Republic | |
| 8607bc9f-f81a-424c-b629-0c3f8428f62f Germany | |
| f8254ec6-eda2-4ee1-b9a7-ba5ffc86eb57 Sweden | |
| 77e5db9c-fccf-4ce8-bc86-98e688420ec6 Croatia | |
| fe5f13b7-1c38-4654-b3d2-1f1f845e40c4 Netherlands | |
| e2928cbd-91eb-4feb-a804-8bf127ff03c6 Finland | |
| fcbbf69f-0ff0-4634-b99f-9bea61ba3040 Portugal | |
| 386b877e-e1d1-40f1-93c4-e1e5d6056b35 Germany | |
| ddb74f2c-9f48-42a9-93df-d8fece47ab44 France | |
| c966dad9-6d00-4f10-8968-453a11e7e17c Poland | |
| 97f608a7-9549-4b48-a006-b313924d3316 Denmark | |
| 8607bc9f-f81a-424c-b629-0c3f8428f62f Germany | |
| 674b03f8-d62f-4dcb-b9bb-fc9b26d63b48 Norway | |
| 77e5db9c-fccf-4ce8-bc86-98e688420ec6 Croatia | |
| 00499bbf-53a8-4943-be10-0b867824abe5 Greece | |
| fe5f13b7-1c38-4654-b3d2-1f1f845e40c4 Netherlands | |
| 7784ab44-9778-469e-b5e0-bff4ff9923a0 Bulgaria | |
| 840626a5-9112-49f1-b2e0-f9e301507c97 Czech Republic | |
| 26643410-dbd9-4b71-9484-a6e877b97c7f Germany | |
| dc0e25f9-4c3f-4660-94e0-3105c1c6891c Hungary | |
| e8d6b925-fdea-4084-af68-149b3a55142e Germany | |
| 47041d43-aed0-4e50-a911-c91d6f1e3392 Sweden | |
| 00499bbf-53a8-4943-be10-0b867824abe5 Greece | |
| aba53e33-6dc2-4173-83d3-5acc96caa559 Belgium | |
| c966dad9-6d00-4f10-8968-453a11e7e17c Poland | |
| 1df997d6-90ee-4f5d-a8d9-2637bf076056 Poland | |
| f8254ec6-eda2-4ee1-b9a7-ba5ffc86eb57 Sweden | |
| aba53e33-6dc2-4173-83d3-5acc96caa559 Belgium | |
| 16a9554e-9bdf-4c56-8a95-1577e48abc14 Poland | |
| 59c3e9b3-0c6d-4eb5-9886-332fe7b094b4 France | |
| e8d6b925-fdea-4084-af68-149b3a55142e Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCSWERAJ200A000000XX |
| EAN | 8015644770389 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 551 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 74 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 81 kg |
| Package Level 1 EAN | 8015644770389 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0434 |
| Technical | |
| Connecting Capacity | 4000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 5000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 15000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 900 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 4000 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 85 kA |
| Overload release current setting (EF002336) | 1600.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 2400.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 6000.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E4.2S 4000 Ekip Hi-Touch LSI 4p WMP - ABB - E4.2S4000 - 1SDA073188R1 | 96 Kbytes |
![]() |
| E4.2S4000 1SDA073188R1 ABB E4.2S 4000 Ekip Hi-Touch LSI 4p WMP | 77 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.