Product successfully added to your shopping cart
1SDA071786R1
ABB
1
E4.2S 3200 Ekip Touch LSIG 4p F HR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E4.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | a64f581a-f68b-4ad5-a764-eb6fc2e1416e Italy |
| Simplified SCIP | 41b71180-d360-467d-b2c7-93d6769bf84b Germany |
| a1fc4e2b-c002-452f-a894-8903cf419184 Germany | |
| 609ed709-545e-4a5e-9aa0-1ab8331b70c1 Germany | |
| c302f828-9818-4e4c-9a83-e0d592601419 Finland | |
| 5f7f076d-f928-474e-9ca1-906c5be128f4 France | |
| c876a760-9fdf-4e4f-95b2-d5f69c845a7f Greece | |
| cff3f7a9-0983-4afe-ad86-9ec370820532 Sweden | |
| 71bbf68a-84ed-4877-b50c-bd3383a81faf Netherlands | |
| 1d7120a9-1162-417e-a31d-654fdd21d520 Estonia | |
| 79d16aa6-706d-4536-ad1b-fae12d435fc4 Belgium | |
| 04238a01-08c3-4dfc-b275-300ebe7c9f93 Germany | |
| b7288246-79f2-4f63-9e1b-be2186ae7f59 Czech Republic | |
| e4e13675-c006-4da0-9aab-967f3a78d2c0 Poland | |
| 2c1cc4d8-1d30-4ed8-a2dd-db2af2bb6271 Poland | |
| a542357b-5849-41d5-83ea-b10f467aa8ad Portugal | |
| da0604d1-9189-4694-9740-c76248f9df8e Bulgaria | |
| 51856006-e487-4827-b90c-1409f22411a4 Sweden | |
| 43381e29-dcac-4aea-a5c8-3748bc847bce Belgium | |
| 8ef1daaf-e49c-4340-994e-e25461148a15 Spain | |
| 004c3417-4656-4132-b83c-0d5d1491378b Hungary | |
| 3d22092d-70ea-43fd-9a05-04dded3bb144 Hungary | |
| baf83598-3dff-4bb3-a312-495c79a20f9c Norway | |
| 32c7541c-4251-4e17-95da-c5b0978edf2a Poland | |
| d6ec475a-c3ee-41cb-b788-54755259517c France | |
| bff0103c-5b81-4256-b996-59f571f14f75 Denmark | |
| f79cea4e-cf8e-4a82-8584-f240c965e6f8 Germany | |
| 3796ca82-2afc-4ab1-ac55-800b91b25f7c Croatia | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCSVENBF000A000000XX |
| EAN | 8015644756369 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 510 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 70 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644756369 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0197 |
| Technical | |
| Connecting Capacity | 3000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 7000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 425 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E4.2S 3200 Ekip Touch LSIG 4p F HR - ABB - E4.2S3200 - 1SDA071786R1 | 91 Kbytes |
![]() |
| E4.2S3200 1SDA071786R1 ABB E4.2S 3200 Ekip Touch LSIG 4p F HR | 80 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.