Product successfully added to your shopping cart
1SDA072427R1
ABB
1
E2.2S 2500 Ekip G Touch LSIG 3p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E2.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 65b49979-6bec-42cf-9774-8fd3cabf12a3 India |
| Simplified SCIP | 59384140-bcd3-41fd-a0cc-fcbadec6a2eb France |
| b333c403-7ae9-4901-bbc0-0a78be80426d Finland | |
| ccbed2a4-b050-49e6-aefd-7ca35ae8a839 Netherlands | |
| 23463406-1aec-4cdf-80b1-e5f72ddf8cdf Poland | |
| 5a4c160d-cc68-4493-bdc8-e50cf10c4e13 Czech Republic | |
| 45862c0e-5158-4f48-b3d0-cf84026070b6 Croatia | |
| 8c47b829-c088-4c70-8aba-8a6fbb5b6acc Hungary | |
| b098c6b0-7817-402f-be07-6d431435556f Spain | |
| e85a9640-9acf-4440-a017-3f4a05d07e84 Belgium | |
| f2b666de-7ffc-4091-88ba-369ec9cf2753 Hungary | |
| 360d0216-fce8-48c2-99fa-4850c2d5c37f Portugal | |
| 73e15098-768f-45b1-a296-c8cfbe498996 France | |
| c6077ad6-a617-4f5a-a5ac-e3d4078ba842 Sweden | |
| 0f45dd32-3676-4135-82b3-3a361a0671ab Germany | |
| 1346c4a9-d116-49ee-b01b-59b3307cf76c Germany | |
| 0df09ada-40f8-41da-9a8d-7e55b3ac70d9 Bulgaria | |
| 8a86b811-eb2c-430c-8b40-0e433f08ba08 Poland | |
| 5382562b-362d-421c-8311-498dbabd8e1a Sweden | |
| 37278c66-fcf2-46b4-b286-a03006896826 Estonia | |
| d3531122-3e8c-4871-8006-53520e202506 Greece | |
| 53d98aeb-fd45-4aff-ad38-80ff81f4f549 Germany | |
| 817048de-7253-45c6-8648-3a6111f7beba Norway | |
| 007e8ecb-6d8a-4147-9a8d-d69e0f499f63 Belgium | |
| 16874f9d-95c0-4563-aca0-1f4e7c38aadd Poland | |
| f003cb6a-2d34-4d56-8f63-3018e18868cd Denmark | |
| 2b36bc97-da52-40d4-a212-fff7ee55ac4d Germany | |
| b69ac3fe-d274-456e-88ec-1d6cd733b0a3 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2SUELAN200A000000XX |
| EAN | 8015644762773 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644762773 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Connecting Capacity | 1800 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 550 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip G Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 2500 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 85 kA |
| Overload release current setting (EF002336) | 1000.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 1500.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 3750.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E2.2S 2500 Ekip G Touch LSIG 3p WMP - ABB - E2.2S2500 - 1SDA072427R1 | 95 Kbytes |
![]() |
| E2.2S2500 1SDA072427R1 ABB E2.2S 2500 Ekip G Touch LSIG 3p WMP | 74 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.