Product successfully added to your shopping cart
1SDA073639R1
ABB
1
E2.2S 250 Ekip Dip LSI 4p F HR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E2.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | d575dc7b-43ae-4d73-97e9-55183a621f72 Italy |
| Simplified SCIP | d21c962d-a895-46e0-b855-45f911d0c556 Germany |
| 2f10aa18-4558-4ba7-9887-136b7636b97e Greece | |
| 9edf89c1-17c8-48ef-adf6-ee63e962917a Croatia | |
| c9b166a6-ed3b-4c0a-b430-03b19caaa30e France | |
| 5bbea5d5-af7f-4d48-bae2-63d0316504ed Portugal | |
| 23d42643-b10e-4f0f-9c2d-0aeab48caf49 Sweden | |
| 17a7fd70-dea0-4319-8a9d-943755f5d660 Bulgaria | |
| da3bc443-fc2a-49a3-8565-b60603317945 Czech Republic | |
| 7b6f582b-208c-4a98-b153-f43c8ada6221 Estonia | |
| f43c130b-d62b-4935-99ca-62a853e9e1e7 Germany | |
| 0e9c5067-f7cb-4211-a74b-38c5db585340 Germany | |
| 1e5bf191-a271-496b-96ad-755d898edba0 Germany | |
| b850c07c-2a13-49de-a816-dcd061ed1220 Poland | |
| 6c5d7fc6-c5c3-429c-9011-5b6f5149ca7e Netherlands | |
| 61578976-7c4e-4cb5-bef8-a91fee8b412b Poland | |
| 8b2e6dff-f48e-4254-b977-a759eba35722 Germany | |
| f45c980d-1c0a-477e-9535-9f17b939b072 Belgium | |
| fe7c11de-ec99-477f-afb1-e0c288604b3b Denmark | |
| d43d6c5b-a104-40aa-a7a3-ea615a7d5748 Finland | |
| ae6d1fd3-f160-4c85-b5aa-324194580322 Sweden | |
| c4d95d0d-da64-45e3-ae0c-092556e1fcef Hungary | |
| e7c64b5e-c8cf-45de-8d6b-23edb7c06b09 Spain | |
| 547b3d30-72b0-48ac-8439-bb11aec862d2 Belgium | |
| 6ce68d26-4cb3-4e62-b2cd-21e2b9791e40 Norway | |
| e145363f-ef16-4f82-a934-731d71f51cec France | |
| 55d62c8f-ee27-4f79-9d22-284838f49479 Hungary | |
| 3838ef94-9510-4fda-844a-f2c6729aba9e Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBSMECBB000A000000XX |
| EAN | 8015644775728 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 58 kg |
| Package Level 1 EAN | 8015644775728 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Connecting Capacity | 120 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 50 W |
| Rated Current (In) | 250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 85 kA |
| Overload release current setting (EF002336) | 100.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 150.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 375.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E2.2S 250 Ekip Dip LSI 4p F HR - ABB - E2.2S250 - 1SDA073639R1 | 89 Kbytes |
![]() |
| E2.2S250 1SDA073639R1 ABB E2.2S 250 Ekip Dip LSI 4p F HR | 74 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.