Product successfully added to your shopping cart
1SDA072898R1
ABB
1
E2.2H 800 Ekip Hi-Touch LSI 4p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E2.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 00d7ed7a-fd24-4380-8d9a-ff02a178b1c4 Italy |
| Simplified SCIP | cfd53bbe-f5f5-4be4-b7f4-30f66914c096 Portugal |
| f2a8a78b-a08f-4632-8d38-df44405e8eed Netherlands | |
| 7018d863-2576-4d6c-856d-1914dc97e78c Poland | |
| 3d4ef85f-f2af-42ac-b59e-edf471865f17 Poland | |
| 9a78d503-cc85-440c-a016-b2dcf4e3e4d2 Germany | |
| 71d7d816-50a6-4349-86a0-a381441b6665 Bulgaria | |
| 4f6206c8-766c-4960-a643-8adf5ba035d7 Germany | |
| c3d581e4-ba38-4c58-8b66-83fc29c7a74c Hungary | |
| c6f4868f-86c8-44c5-a259-f6312a4d458f Poland | |
| 6bbd388b-5394-4167-ab92-4ad48c394932 Czech Republic | |
| f8416874-26dd-4bb8-a2aa-60fcb67aa897 Germany | |
| 2ffe8313-739b-49a8-bc07-c35fa9e9617e Belgium | |
| 6f66fce0-ff8f-4fc4-9d26-d2a5535b7432 Germany | |
| 4cb12adc-b0b8-4c63-a66d-1460bd7c73cb France | |
| e2416e06-2529-4848-8aaa-51bf0cfa2081 Finland | |
| b03f61a2-5b1c-4e8c-8c18-4193741d656b Greece | |
| cfcd6d32-0cfd-4707-a11b-f2d0f0d26192 Denmark | |
| b03f61a2-5b1c-4e8c-8c18-4193741d656b Greece | |
| 330fe251-0b13-4143-b7de-b1de539f2647 Norway | |
| cfd53bbe-f5f5-4be4-b7f4-30f66914c096 Portugal | |
| 4cb12adc-b0b8-4c63-a66d-1460bd7c73cb France | |
| c6f4868f-86c8-44c5-a259-f6312a4d458f Poland | |
| bab7a853-8281-4d8a-b0e5-8b3428f3ba3e Sweden | |
| d93429c9-cd25-48f4-b82c-1643c35836a0 Spain | |
| 6bbd388b-5394-4167-ab92-4ad48c394932 Czech Republic | |
| 4ec2a568-a7db-4156-b4d4-a9689abc37b1 Hungary | |
| 3d4ef85f-f2af-42ac-b59e-edf471865f17 Poland | |
| 2b5d8302-ae47-4c51-ad34-e5546c991490 France | |
| daa23091-2db2-4b12-8aa6-e44dea5f9e58 Estonia | |
| 660f8c7e-fc77-4e3c-9b45-3575f54945d8 Sweden | |
| d93429c9-cd25-48f4-b82c-1643c35836a0 Spain | |
| 558acf93-868e-47bc-93d3-dec5e083abe7 Germany | |
| 9a78d503-cc85-440c-a016-b2dcf4e3e4d2 Germany | |
| f8416874-26dd-4bb8-a2aa-60fcb67aa897 Germany | |
| 330fe251-0b13-4143-b7de-b1de539f2647 Norway | |
| 72b3f61c-2613-4699-8025-0ef3ed848866 Belgium | |
| 2ffe8313-739b-49a8-bc07-c35fa9e9617e Belgium | |
| cfcd6d32-0cfd-4707-a11b-f2d0f0d26192 Denmark | |
| daa23091-2db2-4b12-8aa6-e44dea5f9e58 Estonia | |
| 72b3f61c-2613-4699-8025-0ef3ed848866 Belgium | |
| 2b5d8302-ae47-4c51-ad34-e5546c991490 France | |
| c3d581e4-ba38-4c58-8b66-83fc29c7a74c Hungary | |
| 6f66fce0-ff8f-4fc4-9d26-d2a5535b7432 Germany | |
| e2416e06-2529-4848-8aaa-51bf0cfa2081 Finland | |
| 2658cfdb-6800-4de6-8699-35b181a4a46b Croatia | |
| f2a8a78b-a08f-4632-8d38-df44405e8eed Netherlands | |
| 2658cfdb-6800-4de6-8699-35b181a4a46b Croatia | |
| 660f8c7e-fc77-4e3c-9b45-3575f54945d8 Sweden | |
| 558acf93-868e-47bc-93d3-dec5e083abe7 Germany | |
| 4ec2a568-a7db-4156-b4d4-a9689abc37b1 Hungary | |
| 71d7d816-50a6-4349-86a0-a381441b6665 Bulgaria | |
| bab7a853-8281-4d8a-b0e5-8b3428f3ba3e Sweden | |
| 4f6206c8-766c-4960-a643-8adf5ba035d7 Germany | |
| 7018d863-2576-4d6c-856d-1914dc97e78c Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBHPEFAJ200A000000XX |
| EAN | 8015644767488 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 407 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 55 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 60 kg |
| Package Level 1 EAN | 8015644767488 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0432 |
| Technical | |
| Connecting Capacity | 600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 72 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 800 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 100 kA |
| Overload release current setting (EF002336) | 320.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 480.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1200.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E2.2H 800 Ekip Hi-Touch LSI 4p WMP - ABB - E2.2H800 - 1SDA072898R1 | 95 Kbytes |
![]() |
| E2.2H800 1SDA072898R1 ABB E2.2H 800 Ekip Hi-Touch LSI 4p WMP | 75 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.