ANUNCIAR
1SDA071542R1 ABB E2.2H 800 Ekip Dip LSI 4p F HR View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA071542R1 ABB E2.2H 800 Ekip Dip LSI 4p F HR

1SDA071542R1

ABB

E2.2H 800 Ekip Dip LSI 4p F HR

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E2.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $7,398.32
Unit price: $7,398.32
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2361
Environmental Product Declaration - EPD9AKK108468A1902
9AKK108468A1909
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP1bbdd244-cb8c-4eae-8abe-3a426b753a7f Italy
Simplified SCIP8d0baa9d-3bd6-4258-9591-74430759924d Germany
9f9fdc24-109f-4aa5-837e-0477b80a3703 Poland
e60b6b50-7a1f-4278-89da-cc8f5e50776a Norway
809423cb-ba48-4f54-be83-a13a42a5fd7e France
5362351e-64b8-48ba-85fc-f4631ed09721 Hungary
f79bfbc2-e398-427b-a0b5-94f81069bee0 Netherlands
b5454d76-bbd3-41ad-bda8-a18a0761739d Finland
b2f9c2f3-0e7f-420e-8fa6-cd7139e02a81 Greece
72711c57-7089-4d45-926e-b6c615e51a39 Germany
bb35eb1b-1330-4125-a05d-f157afc096a0 Germany
8a350103-c6d7-478f-85f2-eefc61f264b5 Croatia
f46ed4fc-2315-46cf-a55e-0ad7774534d3 Poland
35eec3e7-082b-40d8-8cbc-6a30f6e5ce22 Czech Republic
0092cc7d-9623-4edc-b9f6-afb519127b19 Poland
f6540f39-2c7b-452b-b593-9ad9599a8c6e Portugal
12eccb82-b4ad-4673-b8dd-bc7c5e1981e7 Sweden
85507d3b-516f-4225-b114-d65752430381 Spain
a4aa6de7-c174-4c21-9a6b-c9c80ce1af4a Belgium
b3bdc091-ab5b-4fc5-ae29-00637031637e Hungary
c1223929-84f8-4492-a260-b6d748392ade Denmark
46581cbc-fa45-4c13-9332-755bd514fca5 Belgium
b6f96475-3556-4a3e-b13b-8fb6c7250448 France
51bd65b0-7fde-4181-8ce1-b39ed5a4a177 Bulgaria
200024f5-8998-4fe3-8ac0-3c798f88639b Sweden
50a49c82-bb2c-4a5b-b589-d90785a77ac2 Estonia
52e862fc-1b99-40d0-8ee7-0125b6522d40 Germany
192e2b44-4d24-4293-b4fc-5bf2a746ca16 Germany
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZBHPEFBB000A000000XX
EAN8015644753924
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width366 mm
Product Net Height371 mm
Product Net Depth / Length270 mm
Product Net Weight53 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width515 mm
Package Level 1 Height610 mm
Package Level 1 Depth / Length615 mm
Package Level 1 Gross Weight58 kg
Package Level 1 EAN8015644753924
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001252R0123
Technical
Connecting Capacity600 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Mechanical Durability25000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss34 W
Rated Current (In)800 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 85 kA
for 3 s 66 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
Rated Uninterrupted Current (Iu)800 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Dip LSI
Release TypeEL
Short-Circuit Performance LevelH
StandardsIEC
Sub-typeE2.2
Suitable for IT NetworksYes, 690V
Terminal Connection TypeRear flat Horizontal
Terminal TypeBolt
Tightening Torque70 N·m
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5902
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH001000R0100 
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH001000R0002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.