ANUNCIAR
1SDA072891R1 ABB E2.2H 800 Ekip Dip LI 4p WMP View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA072891R1 ABB E2.2H 800 Ekip Dip LI 4p WMP

1SDA072891R1

ABB

E2.2H 800 Ekip Dip LI 4p WMP

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E2.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $7,893.45
Unit price: $7,893.45
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2361
Environmental Product Declaration - EPD9AKK108468A1902
9AKK108468A1909
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP835b79d8-7d2d-4821-b204-4ba05aff07e7 Italy
Simplified SCIP00194216-ce2b-4580-b40f-230471a60d3c Belgium
1b8664e2-b686-443d-80fb-ac9a0353a7e9 Sweden
50e35086-12c9-48f8-a825-2a249cd4c913 Germany
efd17ee1-dba4-4c83-9173-0397072fa76f Sweden
6606fbae-b6aa-44c1-996e-4dbdc7a331dd Germany
4570aed2-9549-428f-a9d7-78364ac2646f Poland
30431069-7f91-49d9-b300-29ef70927532 Spain
e2704dda-ea94-4c8c-8fd9-ce302178c93b Poland
fffe3c10-cd73-4e13-bd2f-350c101f7885 Germany
821359cb-e9a0-4886-ab03-c35860d9ad72 Norway
3b1813c6-e1b6-4c04-ab00-26b7b2156785 Germany
5ac62013-64b2-4456-ab41-373213681d55 Germany
f914e4af-493d-4b42-bd9c-d911e1b19230 Netherlands
3a0c6498-2b04-48d8-adb1-b8a71f517f46 Belgium
5ae4bb50-d60a-4bd0-b3f4-589cfd6f08d5 Finland
0bf6f450-b56a-4b24-9e49-3511f0f0665c Denmark
2fb993c3-f346-486e-b74b-bc56f2c437b8 Poland
49b43703-1a9b-4c8f-964e-0a9edcfdcbe2 Bulgaria
8aaa12ba-eadc-408c-b158-bb2fa3d2ecd6 Croatia
203b744c-e064-4dac-b770-9e00f0e53312 Czech Republic
febbc9f7-7805-4311-9fef-3256101b5c95 Greece
5be00860-e0f0-4ca1-b5a9-82073f7b4246 Portugal
a09f0602-3ada-4d89-bd25-17fdb6fda3d5 France
db43009e-9183-48c5-be9b-6d58de1f7d52 France
3bf25ffd-304b-4c26-8f84-4049663f4923 Hungary
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZBHPEFAA000A000000XX
EAN8015644767419
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width407 mm
Product Net Height425 mm
Product Net Depth / Length383 mm
Product Net Weight55 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width515 mm
Package Level 1 Height610 mm
Package Level 1 Depth / Length615 mm
Package Level 1 Gross Weight60 kg
Package Level 1 EAN8015644767419
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionW
CAD Dimensional Drawing1SDH001252R0432
Technical
Connecting Capacity600 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Mechanical Durability25000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss72 W
Rated Current (In)800 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 85 kA
for 3 s 66 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
Rated Uninterrupted Current (Iu)800 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Dip LI
Release TypeEL
Short-Circuit Performance LevelH
StandardsIEC
Sub-typeE2.2
Suitable for IT NetworksYes, 690V
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5902
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH001000R0102 
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH001000R0002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.