Product successfully added to your shopping cart
1SDA072410R1
ABB
1
E2.2H 2000 Ekip G Hi-Touch LSIG 3p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E2.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 7cba92b4-4a61-47cb-8e0f-f24f2c9e758e Italy |
| Simplified SCIP | a81ee67f-bc1d-463c-81af-941a7ec947e8 Germany |
| 247e3f4e-b133-4635-8634-d13f9da4c685 Estonia | |
| 6975758b-828c-499e-bd47-ad34bfd2c7a0 Hungary | |
| 82132a2b-80a8-438b-8608-8d5a9eed1248 Portugal | |
| 7d3e7fb0-12af-4416-ba90-81d51a691835 Bulgaria | |
| a8a9745d-a5bc-419e-81de-4eccca855d78 Greece | |
| 2340ac48-ddb1-4d5f-b9a1-2fb0742073d8 Poland | |
| 691d7401-4bb5-49dc-9d55-35fff068b5fe Sweden | |
| 76ed9875-cefa-4c9d-a589-748e26ab00d4 Germany | |
| 19e62f67-c04d-47a1-a7dc-159f7647fca6 Belgium | |
| cdb02497-e66b-46e5-a375-b64a0876921b France | |
| 38ff90fe-f58a-4eff-9582-202f04a2eb4f Norway | |
| 89d4ce27-d629-4310-a458-6b032b06755d Poland | |
| 16dceab8-a1b1-46a1-ae2c-43d957ad878f Finland | |
| 76966e43-86f6-41fa-ab8b-603032ff6ef5 Belgium | |
| 05aaf3e7-dc89-40d3-960d-551ab7f6bfc5 Germany | |
| 602dbaff-5a53-4886-808f-df15cf35364f Sweden | |
| b9cefa07-79c6-4909-9999-38ab1e008ad5 Croatia | |
| a5eeb550-e796-4f5c-8ddf-a3539d7c68c3 Czech Republic | |
| d2048090-9057-494e-9561-66f35a6e4fab Germany | |
| 0bc7e9b8-50a9-42cf-9984-0d7fbe0a7ab9 Germany | |
| 034cceab-c222-4719-8b85-b9c18c16ee55 Poland | |
| e397ade5-688f-46a6-afd4-2ae4ab0e2b0e Hungary | |
| 312ac930-bb47-4f79-a0a2-9792ccaecfcb Spain | |
| c186922e-249d-4770-8630-1ae693dd335e France | |
| 9828aa3e-2eb1-4b9c-8bc2-6a6fd695c30a Netherlands | |
| f61d91ec-ac47-4726-b3c4-6d91b1fbbe64 Denmark | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2HTEKAQ200A000000XX |
| EAN | 8015644762605 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644762605 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Connecting Capacity | 1800 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 450 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip G Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 2000 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 100 kA |
| Overload release current setting (EF002336) | 2000 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 1200.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 3000.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E2.2H 2000 Ekip G Hi-Touch LSIG 3p WMP - ABB - E2.2H2000 - 1SDA072410R1 | 95 Kbytes |
![]() |
| E2.2H2000 1SDA072410R1 ABB E2.2H 2000 Ekip G Hi-Touch LSIG 3p WMP | 74 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.