ANUNCIAR
1SDA072785R1 ABB E1.2N 1000 Ekip Touch LSI 4p WMP View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA072785R1 ABB E1.2N 1000 Ekip Touch LSI 4p WMP

1SDA072785R1

ABB

E1.2N 1000 Ekip Touch LSI 4p WMP

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E1.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $7,404.80
Unit price: $7,404.80
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2360
Environmental Product Declaration - EPD9AKK108468A1900
9AKK108468A3028
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIPeb2fbb54-cdad-4a75-a43b-ad2fbaee8304 Italy
Simplified SCIP29970431-07bb-4257-ba00-9db2223a0d7a Germany
d0e5b50f-74ef-4af5-b904-fcf58ea8613b Sweden
c946881b-efda-48b0-b65b-b0bb7b3970e6 Belgium
dfdc8af1-6b08-4f65-a2bc-6848e7531609 Spain
6bf1f26a-abe3-451f-aab5-638a0f562b1f France
826c6292-b48b-4439-9215-83a7482c96e8 Hungary
a29e6223-1358-48bc-863c-29d51f329ad8 Norway
87dfc689-722e-4f35-9b2a-f37cc92b628e Hungary
cb469ed7-f28d-4d1d-a3ed-75c10acc746e Poland
54c940fa-dc66-4873-95ea-1a2f85c310b2 France
93706396-7c53-4eaf-a8a2-d72f6c9d052e Germany
80f6e01c-e3c3-4c64-9c6f-e8e60c432cf1 Croatia
6bb852d8-e4ff-46a9-ad07-74d2d9899ba0 Denmark
1989e5c1-0ca9-48f8-8803-761ef4668c43 Germany
9dcd1e31-c962-4e6b-b854-2a1ba7981373 Germany
c2e41493-ff16-4b28-b1cd-4071126a9446 Finland
7183a817-6f0d-406c-b104-2ae06e900642 Germany
d82bd8e1-35be-4bd4-9059-72010ac3d360 Belgium
66589042-9bdf-4e70-b90c-0ae0d8c8ceae Sweden
d23f8f12-ac63-4da9-a727-6bbffe1e689c Netherlands
f9cb7ef5-d2f0-44a5-80c2-bda21cd7acbc Estonia
12174979-887c-49fe-a4a9-80e7ab3d73bf Greece
e5ac665b-47f8-4af2-a28d-74798fd0cd44 Poland
814299a7-49f9-41fd-a221-d9696be1ea16 Poland
183b7ea2-89da-452b-a82d-9b309a29a0aa Czech Republic
b52a4c52-6101-4b84-902f-491616fde2f2 Portugal
ba85a38f-ecfe-4b82-8cbc-cda67744c5df Bulgaria
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZANQEGAE000A000000XX
EAN8015644766351
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width348 mm
Product Net Height363.5 mm
Product Net Depth / Length271 mm
Product Net Weight20 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width350 mm
Package Level 1 Height350 mm
Package Level 1 Depth / Length330 mm
Package Level 1 Gross Weight23 kg
Package Level 1 EAN8015644766351
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionW
CAD Dimensional Drawing1SDH001252R0065
Technical
Connecting Capacity1000 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss156 W
Rated Current (In)1000 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 50 kA
(230 V AC) 50 kA
(380 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 50 kA
for 3 s 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
Rated Uninterrupted Current (Iu)1000 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Touch LSI
Release TypeEL
Short-Circuit Performance LevelN
StandardsIEC
Sub-typeE1.2
Suitable for IT NetworksYes, 690V
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5546
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH000999R0103
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH000999R0002
Instructions and Manuals (Part 2)1SDH001316R1002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.