Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 7ca5eae2-dd17-44b1-98e9-e446186c6e3e Italy |
| Simplified SCIP | de619fd3-87b0-4896-b72a-ae2b61ba073e France |
| ce97972e-3b97-4595-9d2b-d6a594aa1244 Norway | |
| cf0316ad-1df7-45ae-baaa-01aab6cc632c Germany | |
| 3a006fc1-44cb-4f19-b532-cf123a5a967d Sweden | |
| ad53a5a6-36fa-495a-b6c0-b7ae14a03088 Finland | |
| 81754b70-7879-4c9d-b965-a2f16dbdc1c4 Germany | |
| c15de7b6-8268-4431-badb-38d552c050ff Bulgaria | |
| 879e5450-be7a-4e55-b50a-61f5ab2e4cf5 Denmark | |
| 0f0db4a2-91e7-41f9-ae7e-07daf834ad2c Croatia | |
| 81754b70-7879-4c9d-b965-a2f16dbdc1c4 Germany | |
| ce97972e-3b97-4595-9d2b-d6a594aa1244 Norway | |
| b79d3ab9-de56-448c-885b-6a8fae626166 Germany | |
| 879e5450-be7a-4e55-b50a-61f5ab2e4cf5 Denmark | |
| 49aa9cf6-12e8-4b44-a0df-53b59f623ec0 Poland | |
| b79d3ab9-de56-448c-885b-6a8fae626166 Germany | |
| e6cc777e-6676-404a-a6d7-31283f36241b Poland | |
| 52af4b8a-3553-44d0-b3f9-0945afc586fb Greece | |
| cf0316ad-1df7-45ae-baaa-01aab6cc632c Germany | |
| e4d6824a-bc03-4141-85ff-9ef00360ce14 Belgium | |
| 0a3b83b8-b387-41e0-8aa8-492963201a6d Netherlands | |
| dac16529-be97-4a24-8610-6a476b16ddf6 Poland | |
| 7140c554-cb46-4fff-b3fe-1b7cc134dad0 Belgium | |
| e6cc777e-6676-404a-a6d7-31283f36241b Poland | |
| e4d6824a-bc03-4141-85ff-9ef00360ce14 Belgium | |
| 0f0db4a2-91e7-41f9-ae7e-07daf834ad2c Croatia | |
| a16c01a8-be45-4eb5-966b-5e4597ff9a11 Sweden | |
| 8e29c531-34ef-42df-bcde-d4166c020d0b Czech Republic | |
| ad53a5a6-36fa-495a-b6c0-b7ae14a03088 Finland | |
| 5fcb681c-487d-428a-8d15-1378894c72d5 Portugal | |
| fdb27c4d-5259-4cce-8844-bf8bbeb90807 France | |
| b83decc3-af2a-40ac-8758-c08fec4dd61a Germany | |
| 28a2564d-2006-474f-9899-7126548dc1b8 Germany | |
| d108e790-d91b-4da4-9962-a6f3a7479cac Hungary | |
| c15de7b6-8268-4431-badb-38d552c050ff Bulgaria | |
| 8e29c531-34ef-42df-bcde-d4166c020d0b Czech Republic | |
| 7140c554-cb46-4fff-b3fe-1b7cc134dad0 Belgium | |
| f2241401-2621-423d-988b-3718c78a8f92 Spain | |
| ed6e09ae-3fec-4813-91fb-2a09d74b219b Hungary | |
| 5fcb681c-487d-428a-8d15-1378894c72d5 Portugal | |
| f2241401-2621-423d-988b-3718c78a8f92 Spain | |
| ed6e09ae-3fec-4813-91fb-2a09d74b219b Hungary | |
| 320b2050-96c0-4cba-9544-ca97955947a6 Estonia | |
| 0a3b83b8-b387-41e0-8aa8-492963201a6d Netherlands | |
| 52af4b8a-3553-44d0-b3f9-0945afc586fb Greece | |
| de619fd3-87b0-4896-b72a-ae2b61ba073e France | |
| d108e790-d91b-4da4-9962-a6f3a7479cac Hungary | |
| 320b2050-96c0-4cba-9544-ca97955947a6 Estonia | |
| dac16529-be97-4a24-8610-6a476b16ddf6 Poland | |
| fdb27c4d-5259-4cce-8844-bf8bbeb90807 France | |
| 49aa9cf6-12e8-4b44-a0df-53b59f623ec0 Poland | |
| 3a006fc1-44cb-4f19-b532-cf123a5a967d Sweden | |
| 28a2564d-2006-474f-9899-7126548dc1b8 Germany | |
| b83decc3-af2a-40ac-8758-c08fec4dd61a Germany | |
| a16c01a8-be45-4eb5-966b-5e4597ff9a11 Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CPEFAE000A000000XX |
| EAN | 8015644759551 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759551 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 100 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 800 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 50 kA |
| Overload release current setting (EF002336) | 320.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 480.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1200.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2C 800 Ekip Touch LSI 3p WMP - ABB - E1.2C800 - 1SDA072105R1 | 95 Kbytes |
![]() |
| E1.2C800 1SDA072105R1 ABB E1.2C 800 Ekip Touch LSI 3p WMP | 75 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.