Product successfully added to your shopping cart
1SDA070755R1
ABB
1
E1.2C 800 Ekip Touch LSI 3p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 6daf2ec2-e6a0-4404-a771-e25bb3a6f144 Italy |
| Simplified SCIP | 4acc1e47-f7d8-4d18-a7c4-99d080a40b98 Bulgaria |
| bd6aeab8-9e4e-4b19-bd5d-63a096a6d175 Denmark | |
| b9888195-0288-42f5-92a7-d5e12c5c0689 Germany | |
| 16a85f33-7722-4ca3-8296-cc47eaf07f75 France | |
| 1369a33f-1963-4b57-8474-e6ec24e201fe Norway | |
| ce4df47c-a97f-4c4c-b908-f378a67b7d4e Greece | |
| d5dd11f2-a729-41ca-968f-c7e09bfa3477 Germany | |
| af2734fe-f905-4d39-b288-ddab5ccbe3f4 Finland | |
| ee3d9338-4ee7-49ad-bd85-3f20ab083045 Czech Republic | |
| 86403ff0-e86d-4e12-b6fa-25a8649e6fa4 Portugal | |
| d4b50139-ff9e-4439-b262-4e58f6a34500 Croatia | |
| 13caf053-52ff-42c3-943e-7ddff319b969 Sweden | |
| 052c01a2-af17-459e-af49-ab774eed6a4b Germany | |
| a37dfced-eb85-42d0-8c96-0ef639815280 Hungary | |
| dc715bb2-b6af-45c8-994f-152f2662535b Germany | |
| 8597164c-a4b9-41ea-90b6-83ae8d0e7e49 Poland | |
| 9f7a352f-909b-4673-9e5d-4aff94362d76 Netherlands | |
| af0dc8df-fccc-4eda-9534-0d93938dfbc0 Poland | |
| d1f788e2-9530-495c-8a9e-30d03f1137ba France | |
| 00a7d92c-26a9-4c2d-8a07-964c1272c89f Hungary | |
| 346e2a4e-177f-49e6-9f1c-193a4f5545d4 Spain | |
| 2a53a7c3-8b57-48df-bb06-d12f7adc99c0 Belgium | |
| b5323cc4-98c8-48d9-9cd2-fcc0ede1a6cd Estonia | |
| 0eff54b9-e5f9-4600-a950-025b21a388ee Poland | |
| 84abefab-1730-4902-8b42-406f8a4c8c3a Sweden | |
| 0ddff0f3-8c5e-4a5d-9922-a7071ff3b21f Belgium | |
| 6c2bf012-7666-45fb-b4ce-30f98cda82fc Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CPEFBE000A000000XX |
| EAN | 8015644746056 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644746056 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0109 |
| 1SDC200023D0209 | |
| 1SDC200023D0709 | |
| 1SDC200023D0309 | |
| 1SDC200023D0909 | |
| 1SXF200023C2001 | |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0003 |
| 1SDH000999R0002 | |
| 1SDH000999R0005 | |
| 1SDH000999R0004 | |
| 1SDH000999R0001 | |
| 1SDH000999R0006 | |
| Instructions and Manuals (Part 2) | 1SDH001316R1003 |
| 1SDH001316R1002 | |
| 1SDH001316R1005 | |
| 1SDH001316R1004 | |
| 1SDH001316R1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2C 800 Ekip Touch LSI 3p F F - ABB - E1.2C800 - 1SDA070755R1 | 89 Kbytes |
![]() |
| E1.2C800 1SDA070755R1 ABB E1.2C 800 Ekip Touch LSI 3p F F | 74 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.